Get complete information related to latest Meter Block Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Block Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Block Tenders.
Tender For corrigendum : supply of digital dc insulation tester (meggar) , digital micro ohm meter , digital winding resistance ohm meter , automatic 3-ph transformer turns ratio tester , portable cable fault locator , portable earthing resistance measuring device
Tender For supply of removing the existing compact sub stn , taking out and transporting defective css , servicing of rmu 11kv model of c and s make , supply and fixing in replacement of vaccum , supply and fixing of digital amp meter , supply and fixing of digital volt meter , supply and fixing in replacement indicator lamp , supply and fixing in replacement 11kv , opening up the top cover of the transformer , supply and fixing in replacement ht coils , supply and replacement of lt coils , supply and fixing in replacement of gasket , supply and fixing in replacement of lt porcelain , supply and fixing in replacement of ht 11 kv , supply and fixing new transformer oil , filtration dehydration of transformer oil , supply and fixing in replacement of supply testing , exacavation for cables loops near the poles , material and labour for repairing existing lt panel , material and labour for preparing old painted , servicing of acb model 2013 , supply and fixing of shunt coil assemply , supply and fixing of spring charging motor , supply and fixing in replacement of mccb 250 amps , supply and fixing in replacement of mccb 160 amps , cable jointing kit for 11 kv
Tender For corrigendum : supply of smart energy meters with head end system services in gift city - 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009631: 3p4w 240v 10-100a cl1.0 wc smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 3 phase 4 wire, isi marked, 1.0 class accuracy, 10-100 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009632: 3p4w 240v -/5a cl0.5s ct smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of 3 phase 4 wire, isi marked, 0.5s class accuracy, fully static lt current transformer (ct) operated smart energy meter with dlms protocol & bidirectional communication facility. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 2 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 0.5s for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communication module fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads havin