Get complete information related to latest Micro Controller Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Micro Controller Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Micro Controller Tenders.
Tender For supply of high voltage fuse of rating 2a, 1.2kv ac as per part no 184000.2 of siba of size 8x50 m m for use in primary circuit of 100va control transformer of lhb ac/non-ac/hog coaches as per rdso spec no rdso/pe/spec/ac/0184-2015(rev 1)or edts 355 rev 1 amendment 1&2, also confirming t o rdso l. no. el/7.1.108/mssbc dt. 17.09.2021. or latest, make eti/eaton/ bussman/l&t/siemens/abb/siba/wohner/ferraz only. [ warranty period: 30 months after the date of deliv ery ]
Tender For supply of contactor for electronics and control circuit, contactor type-c164c/110et), make schalt bau.gmbh pt. no. 1-1622-251457.clw specn. no. clw/es/3/0034alt-c or latest spec. /drg. no.: -clw specn. no. clw/es/3/0034alt-c or latest [ warranty period: 30 months after the date of delivery ]
Tender For supply of spares for sait mine line make starter - cu bus bar, pvc slvd 25x8 wand cable clamp cb480kwbbr400 , busbar support bs480kwbs50 , isolator bush nylon ib480kwbsh3 , limit switch for isolator lsfi480kwei , ht pt fuse htptf480kwavt , ht pt fuse support htptfs480kwbs45fs , vacuum contactor 3 point 3 kv, coi l 220v ac vc480kwsavac4 , closing coil of vacuum contractor ccvc480kwvcccc , vcc aux point contact vac480kwvccacb , 1 ph pt 3 point 3 110v i 110v ac 1phpt480kwb2spf2v , current transformer ct480kwstd , main fuse mf480kwstd , control fuse cf480kwns , earth leakage relay, 220vac wand cbt 80mm2 elr480kwelm8 , ammeter am480kwpa1100 , push buttons actuator green and red pba480kwpb , led indicator lamp green lilg480kw110vac , led indicator lamp red lilr480kw110vac , led indicator lamp amber lila480kw110vac , aux contactor 2no plus 2nc 220v ac ac2nonc480kwka , electronic timer et480kwbo2aodt5 , cluster indicating lamp cil480kwlab9 , control circuit breaker ccb480kwbocsmbs2c6 , thermal o and l with spp tol480kw3ua50001f , ht bushing for outgoing htbo480kwhttb10
Tender For supply of cover bolts part no 000110a , isolator assly k3 on off part no 050000 , overload assembly breaker 210a 300a part no 110100c , shunt trip assy 11 point o3 point 00 9 mine line part no 110300 , no volt coil assy 110400 part no 110400 , potential transformer part no ds , incoming gland part no g1 , outgoing gland part no g2 , outgoing gland part no g3 , indicating lamp with pcb mounting part no lab9 , sealing box complete part no s1 , circuit breaker for 100a with complete a part no wr1 , earth leakage relay 50 750 ma 750ma with part no elm7la , core balance transformer part no cbt90m , fixed contact assy 05 point 01 point 00 mine line part no 50100 , moving contact assembly for isolator part no 050200 , shunt trip coils part no 110301 , no volt coilunder voltage coil part no 110402 , catcher assy 11 point 05 point 31 part no 110531 , fixed contact assembly for breaker part no 110600 , arc chutes part no ac1 , ammeter part no am , push button actuator for el test part no boes2 , reset push button contact element part no boes3 , terminal bushing with insulator dmc inco part no t5 , on off isolator 300a part no k4 , circuit breaker for 200a with complete a part no wr2 , complete control wiring including pla r part no wr2a , limit switch no plus nc for breaker part no mcr16d , no volt coil assy under voltage coil as part no 110400a , micro switch part no 50502 , current transformer for ol part no lat3005 , earth leakage relay 50 750ma 2a dual part no elm7dlas , push button with spindle part no pbs , brass terminal with dmc bushing part no t8 , core balance transformer part no cbt150m , busbar part no bbr300 , thermal overload relay part no 120021 , current transformer for ammeter part no 12020055 , potential transformer type d part no ds , overload coil 400a part no 110105 , dashpot cup part no 110106 , flexible copper braids with lugs part no fcs , moving contact assembly for breaker part no 110200 , single phasing preventor with module part no spp5cmsp
Tender For supply, erection, testing and commissioning of panel air conditioning unit with following spec ifications: (1) cooling capacity: minimum 2400 watts. (2) dimensions: should not be more than 1300mm (h ), 440mm (w), 300mm(d). (3) operating voltage: 230v ac or 415v 3 phase ac. (4) refrigerant used: r407 c / r134a or any other environment friendly gases with lesser gwp. (5) mounting type: vertical type side m ounting / face mounting. (6) application: for cooling electrical control panel. (7) ambient temperature: 25 t o 45 degrees celsius. (8) set temperature: 25 to 30 degree celsius. (9) temperature controller: microproce ssor based controller with digital display. (10) alarm : potential free output for high temperature. (11) suita ble alarms /indications shall be provided for faulty operations. (12) make: rittal, advance or lex make only. (13) panel shall be designed with dust proof feature suitable for dusty industry application. (14) manual: on e set of operating manual & electrical circuit drawing in english to be submitted along with the supply. (15) product catalogue with required information/details shall be uploaded with the offer for verifying the specifi cation. (16) manufacturer's test report for the model shall be submitted along with the supply. [ warranty period: 12 months after the date of delivery ]
Tender For supply, erection, testing and commissioning of panel air conditioning unit with following spec ifications: 1. cooling capacity: minimum 3500 watts or 3000kcal/hr. 2. dimensions: should not be more tha n 1550mm (h), 440mm (w), 300mm(d) 3. operating voltage: 230v ac or 415v 3 phase ac 4. refrigerant u sed: r407c / r134a or any other environment friendly gases with lesser gwp 5. mounting type: vertical typ e side mounting / face mounting 6. application: for cooling electrical control panel 7. ambient temperature: 25 to 45 degrees celsius 8. set temperature(target temperature): 25 to 30 degree celsius 9. temperature controller: microprocessor based controller with digital display. 10. alarm : potential free output for high te mperature . 11. suitable alarms /indications shall be provided for faulty operations 12. make: rittal, advanc e or lex make only. 13. panel shall be designed with dust proof feature suitable for dusty industry applicati on. 14. product catalogue with required information/details shall be uploaded with the offer for verifying the specification 15. manual: one set of operating manual & electrical circuit drawing in english to be submitte d along with the supply. [ warranty period: 12 months after the date of delivery ]