Get complete information related to latest Motor Starter Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Motor Starter Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Motor Starter Panel Tenders.
Tender For supply of ball bearing slew ring , high pressure variable displ piston pump , unloading manifold , check valve , ventable relief valve , 24v dc on off valve , bell housing , coupling , pvg directional control valve , service kit for pvg 16 , wired remote , joysticks , wire rope 20mm , manhole cover rubber , hydraulic hoses different sizes , ab plc micro logix 800 with prog and calibration , directional control valve controller , hoist winch lower limit contrlr and manifold , slew drive with pinion of manifold , luffing cylinder manifold with cartridge valves , luffing cylinder service kit , 2 pole mcb , mushroom turn to release push button red colour with 1 nc , selector switch 2 maintained with 1no contact , shrouded push button blue with 1no contact , indication lamp integral led green 24vdc , indication lamp integral led red 230vac , indicat lamp integral led yellow 230vac , indicat lamp integral led blue 230vac , incoming contactor , indication lamp integral led red 24vdc , 1 pole mcb , panel space heater , thermostat , star delta contactor 40a
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For corrigendum : procurement of jcb spares ap demand - 320 a7291 333 y6130 water separator assembly 3dx super ch xxx a , 450 00202 drive flange 3dx super ch xxiii d , 334 y6169 hose 10 bsp hp 850 hyd pump to steer va 3dx super ch iv a , 4102 2800 sealant yellow sikaflex 221 30ml 3dx super ch iii h , 126 01153 lever parking brake 1 , 336 y2341 chart lubricant 3dx super ch iv a , 730 03601 fire extinguisher 3dx super ch vii e , 336 y2342 decal warning 3dx super ch iv a , 333 y9063 stopper plate 3dx super ch iv b , 333 y0334 liner roof assembly 3dx super ch iv f , 4101 1100 loctite 243 3dx super ch iv f t , 335 y3428 support roof liner 3dx super ch iv f , 335 y9798 pipe cover front 3dx super ch iv w , 335 y9799 pipe cover side left hand 3dx super ch iv w , 335 y9803 cover pipe front 3dx super ch iv w , 335 y9804 cover pipe side right hand 3dx super ch iv w , 332 g6710 clamping ring 3dx super ch iv w , 334 y7743 console front 3dx super ch iv aa , 335 y9811 rear valance 3dx super ch iv ai , 4101 0300 fluid locking 3dx super ch vi h , 225 35203 mount resilient 3dx super ch xii a , 333 y3532 steering column assembly fixed 3dx super ch xii a ch xxx1 aa , 336 y2361 decal dipper 3dx super army 3dx super ch vii a , 336 y2563 jcb decal artwork armay 3dx super ch vii a , 335 y6827 hose st pump 3dx super ch xiii h , 335 y7881 bracket mounting fire extinguisher 3dx super ch vii d , 333c 2389 mount throttle 3dx super ch x a , 335 b2589 hose 6 bsp hp 2020mm 3dx super ch xvii b , 335 e6978 bush cylinder 3dx super ch xvi n , 335 y0614 bracket side panel mounting 3dx super ch xxviii b , 334 y0568 plate anti re circ 3dx super ch xxviii c , 334 y2232 bracket hose guide 3dx super ch xxviii e , 320 08587 bracket idler non ac 3dx super ch xxix b , 128 17521 pivots clam jaw 3dx super ch xxxi a , 811 20008 pin pivot 600mm 23 inch wide jaw 3dx super ch xxxi f , 1089 0005 collar 3dx super ch xxxi f , 400 p9452 pin 44 point 45 44 point 35 x 273 3dx super ch xxxi f , 400 r5051 bush 55 45 3dx super ch xxxi f , 332 y2824 hose 3dx super ch xxxi p , 130 07245 stopper 3dx super ch xxxi t , 334 y0469 manifold ga valve 3dx super ch xxxi aa
Tender For corrigendum : tender for supply of operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days iincluding sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications. for first year , operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days including sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications.for second year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starterpanels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for first year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starterpanels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for second year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for first year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for second year , repairing damaged insulation of exposed ac ducts by scrapping and cleaning the surface , applying cold bitumin or adhesives , supplying and fixing of 50mm thick thermo coal sheet (eps) and wraped canvas clothes with suitable self adhesive as