Web Analytics Made Easy - StatCounter

Ms Enclosure Tenders

Get complete information related to latest Ms Enclosure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Enclosure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Enclosure Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45627343 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : supply of on load change over switch 200a, 4 pole, 415vac, hz-50 with ms enclosure, make-hpl electric / havells / philips [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45616675 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For three phase inductive load bank of transformer testing supply 415v ac, 4 wire, 50hz, maximum current 227a, resolution steps: 2 * 1 no, 10 amps * 1 no, 40 amps * 1 no, 50 amps * 1 no, 100 amps* 1 no, switchgears make: abb/siemens/schneider industrial ms enclosure with ventilation [ warranty period: 30 months after the date of delivery ] ]

CTN :45608455 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status

corporations/Associations/Others

CTN :45522640 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For auction sale of bharti tower _damaged floor tiles 600*600/false ceiling tiles 2x2,bharti tower _gypsum tile grid false ceiling 2x2 channel,bharti tower _p. (pac control mcb box ),bharti tower _absolut smoke detector,bharti tower _faulty cctv dome camera (ip)/ faulty cctv ptz , etc,bharti tower _old ddc panel with easy i/o controller,bharti tower _dg exhaust ms pipe with cladding,chennai -2_p. scrap,chennai -2_dg canopy doors (ms doors with glass wool packed) & ms scarp,chennai -2_carton box,chennai -2_wood pallet,oceanic tower_aluminum busbar with ms enclosure (length, l-band, flange )

CTN :45430790 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of mechanical engineering lab materials - mechanical engineering lab materials, serve motor drive kitinterface l293d motor driver ic with arduino to control direction of rotation of two dc motors), bldc motor kitbldc motor 1 nobldc motor drive -1noinbuilt volt and ammeter and rpm meterinbuilt power supplyinput 230v ac, lvdt trainer kit complete educational trainer for linear variable differential transformer (lvdt) displacement measurement. built-in ac excitation source and signal conditioning circuitry for lvdt operation. micrometer assembly for precise linear movement of the lvdt core. displacement range ~10 mm with clear front-panel adjustments for zero & calibration. digital display (typically 3 -digit) for direct readout of conditioned output/displacement values. test points and banana sockets for signal observation on external instruments. self-contained unit in a durable enclosure with labeled controls and educational layout. includes user manual and patch cords for experiments. operates on 230 v ac, 50 hz mains supply., multi-cylinder petrolphase : single phase load: mechanical load with ropenumber of cylinders : 4displacement : rope brakepower : 65hp,4000 rpm,1396 ccbrand material : mild steelengine type : 4 stroke self startfrequency : 15hzfuel consumption : petrolfuel tank capacity : 5 letermorh s test rig, tail stock assemblyheavy-duty lathe tailstock assembly for training; cast iron body with base, barrel (quill) ~50 75 mm stroke, hand wheel feed, dead centre mt2/mt3, set over screws for taper turning, spindle clamp, complete with all internal parts for dismantling and reassembly; suitable for 300 400 mm centre height training lathe., dc motorvoltage 220-440 v dcpower - 180 w speed - 200 rpm, hydraulic cylinderdouble acting hydraulic cylinder, bore 40 50 mm, stroke 200 300 mm, working pressure up to 100 160 bar, steel tube with honed bore, hard chromed piston rod, front & rear end caps, piston with seals and wear rings. supplied as standalone unit with suitable mounting for dismantling, inspection and reassembly., hydraulic opreated directional control valve (dcv)manually operated 3/2 or 4/2 way spool type hydraulic directional control valve, nominal size ng06 (cetop 3) or equivalent, rated pressure 210 bar, flow 20 40 lpm; valve body with hardened and ground spool, centering springs, ports p a b t clearly marked. supplied on small mounting plate for dismantling, inspection and assembly practice., bearing with shaft assemblyteaching unit with shaft 25 35 mm dia mounted in housing with deep groove ball bearings (6205 / 6206 class) at both ends; includes locking arrangements (circlips, lock nuts, covers). designed for repeated removal, cleaning, lubrication and refitting of bearings, with provision to mount on bench or test rig., coupling unit using driving and driven shaft plumber block bearing unit1. the plummer block housingmaterial: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing).sealing: felt seals or v-ring seals (to demonstrate lubrication retention).lubrication: provided with a grease nipple at the top center for manual lubrication practice.2. the bearingtype: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series).bore diameter: standard 25mm or 30 mm (ideal for lab scale).mounting: adapter sleeve mounting (h-series) to teach students how to lock a bearing onto a smooth shaft.3. shafting and couplingshaft material: ground carbon steel (en8 or en9) for high surface finish.coupling type: * flexible coupling: to demonstrate the bearings ability to handle slight misalignment.rigid flange coupling: to demonstrate traditional direct connection.driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven)., spring test machine load & displacement sensing load cel * capacity: 0 10 kno accuracy: 1% fs (better if 0.5% fs) displacement sensor * lvdt / digital encodero accur

State Government

CTN :45414572 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For purchase of electrical material for student activity centre and department of languages in mdu - aluminum bus bar,250 amp. 4 pole mccb 25 ka with 2 spreader link set, ms enclosure 250 amp. mccb, fastner 10 mm nut bolt type, aluminium thimble 120 mmsq, lt outdoor approxi joint kit 185 sqmm 4 core, hardner and compound

CTN :45404153 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment forelectrical and electronics engineering departmen, loading rheostat 3 phase :specification :rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 1 phase :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase capacitor bank :specification :3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , plc tranier kit:specification :plc make :allen-bradley / delta electronics / siemens orequivalentdigital inputs : 8 20 nos.digital outputs : 6 12 nos. (led / relay type indication)communication port : rs232 / usb / ethernet (if available)programming method : ladder logic programmingtoggle switches for digital input simulationled indicators for output status indicationanalog potentiometers for analog input experimentsproximity sensor interface providedrelay output interface providedinput supply : 230 v ac, 50 hzbuilt-in regulated 24 v dc power supplyladder diagram programming software to be providedcompatible programming software license to be providedsuitable for basic plc programming and automationexperiments

CTN :45363405 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For supply of equipment items - , "acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications ", "3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided ", "linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided "

CTN :45343639 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of equipment items - acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications , 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided

CTN :45351357 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
 Loading, Please wait...

Connect us via What's Up