Get complete information related to latest Ms Enclosure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Enclosure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Enclosure Tenders.
Tender For corrigendum : supply of on load change over switch 200a, 4 pole, 415vac, hz-50 with msenclosure, make-hpl electric / havells / philips [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status
Tender For three phase inductive load bank of transformer testing supply 415v ac, 4 wire, 50hz, maximum current 227a, resolution steps: 2 * 1 no, 10 amps * 1 no, 40 amps * 1 no, 50 amps * 1 no, 100 amps* 1 no, switchgears make: abb/siemens/schneider industrial msenclosure with ventilation [ warranty period: 30 months after the date of delivery ] ]
Tender For dismantling and shifting of electrical equipments with associated material from rsu lajpat nagar-3 to t.e. bldg. okhla, mtnl, new delhi - dismantling, loading, unloading, transportation, shifting of old silent type dg set of capacity 63 kva, silent canopy, silencer, exhaust pipe, panels, power cables, battery chargers, batteries, diesel tanks and all other accessories i/c ducting, disconnection of supply cable i/c shifting from rsu lajpat nagar-3 to te bldg. okhla (and re-assembling the same i/c canopy at new site) as per the directions of engineer in charge etc complete as required., dismantling, loading, unloading, transportation and shifting from rsu lajpat nagar-3 to te bldg. okhla of following electrical equipments etc. complete as required.a) 94.5 kva avr with avr bypass panel, b) lt panel, c) capacitor panel, d) power room panel, e)7.5 tr ductable ac units complete with indoor/ outdoor units, f) ac panel, g)focus lights/emergency lights, h) mccb 100/200/250a with mccb box, i) fire detection and alarm system with fire panels, detectors, ri, mcp and hooters, fire cylinders ,buckets and all accessories, j) various sizes copper/ aluminium conductor electrical cables, k) cable runway trays, l) air circulator/exhaust fan/wall fan/ceiling fan/ac fresh air fan, m) 1x40 w/ 2 x 40 w tube light fittings/ halogen light / bulk head/ cfl fittings (approx 20 nos.), n) 100/200/250/400 amp. changeover switch with adopter box, o) ac copper pipes, p) tpdb/spdb 8 way/12 way with mcbs/isolators and adopter boxes, q)power protection box/alarm box/contactor box, dismentalling of burnt out/unserviceable material and shifting from rsu lajpat nagar-3 to te bldg.okhla i.e. ac drain pipes, ac condenser frames , water motor, air curtain,gi earth strip, single core copper wiring, conduit pipes, ms boxes, power point boxes, computer point boxes, switches, sockets, old tube lights, slotted angle pieces,fitting louvers, gi duct pieces, duct insulation,angle iron supports i/c removing from wall/surface etc. as per the directions of engineer-in-charge.
Tender For purchase of electrical material for student activity centre and department of languages in mdu - aluminum bus bar,250 amp. 4 pole mccb 25 ka with 2 spreader link set, msenclosure 250 amp. mccb, fastner 10 mm nut bolt type, aluminium thimble 120 mmsq, lt outdoor approxi joint kit 185 sqmm 4 core, hardner and compound
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment forelectrical and electronics engineering departmen, loading rheostat 3 phase :specification :rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 1 phase :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase capacitor bank :specification :3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , plc tranier kit:specification :plc make :allen-bradley / delta electronics / siemens orequivalentdigital inputs : 8 20 nos.digital outputs : 6 12 nos. (led / relay type indication)communication port : rs232 / usb / ethernet (if available)programming method : ladder logic programmingtoggle switches for digital input simulationled indicators for output status indicationanalog potentiometers for analog input experimentsproximity sensor interface providedrelay output interface providedinput supply : 230 v ac, 50 hzbuilt-in regulated 24 v dc power supplyladder diagram programming software to be providedcompatible programming software license to be providedsuitable for basic plc programming and automationexperiments
Tender For supply of equipment items - , "acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications ", "3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided ", "linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided "
Tender For supply of equipment items - acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications , 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided