Get complete information related to latest Ms Enclosure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Enclosure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Enclosure Tenders.
Tender For dee shackle patt. no. 0263/721-6089. ss to aisi 316 bright finish , turnbuckle assembly without slip 0263/539-6387 0.75t s. w. l. ss to aisi 316 bright finish , ferrule for 10mm f. s. w. r 0263/411-9736 , ferrule for 14 mm f. s. w. r 0263/411-9738 , thimble to suit 10mm f. s. w. r 0263/923-6988. ss to aisi 316 bright finish
Tender For corrigendum : supply of on load change over switch 200a, 4 pole, 415vac, hz-50 with msenclosure, make-hpl electric / havells / philips [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status
Tender For three phase inductive load bank of transformer testing supply 415v ac, 4 wire, 50hz, maximum current 227a, resolution steps: 2 * 1 no, 10 amps * 1 no, 40 amps * 1 no, 50 amps * 1 no, 100 amps* 1 no, switchgears make: abb/siemens/schneider industrial msenclosure with ventilation [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of electrical material for student activity centre and department of languages in mdu - aluminum bus bar,250 amp. 4 pole mccb 25 ka with 2 spreader link set, msenclosure 250 amp. mccb, fastner 10 mm nut bolt type, aluminium thimble 120 mmsq, lt outdoor approxi joint kit 185 sqmm 4 core, hardner and compound
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment forelectrical and electronics engineering departmen, loading rheostat 3 phase :specification :rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 1 phase :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase capacitor bank :specification :3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , plc tranier kit:specification :plc make :allen-bradley / delta electronics / siemens orequivalentdigital inputs : 8 20 nos.digital outputs : 6 12 nos. (led / relay type indication)communication port : rs232 / usb / ethernet (if available)programming method : ladder logic programmingtoggle switches for digital input simulationled indicators for output status indicationanalog potentiometers for analog input experimentsproximity sensor interface providedrelay output interface providedinput supply : 230 v ac, 50 hzbuilt-in regulated 24 v dc power supplyladder diagram programming software to be providedcompatible programming software license to be providedsuitable for basic plc programming and automationexperiments