Get complete information related to latest Ms Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Wire Tenders.
Tender For supply of 10.0 sq. mm. , frls, 3-core hrpvc flat cable, copper conductor with pvc insulation and sheath for working voltages up to and including 1100 volts three core, stranded pvc, type c heat-resistant cables (hr) as per is 5831 latest, type st2 cables sheathed with 85 degree celsius hrpvc compound to is 5831 latest, flexible isi marked cable with flexible ec grade copper conductor wire for submersible pumps as per is:694:2010 or latest. make: havells/polycab/finolex/nicco/ajanta/apar/kei
Tender For maintenance of electrical installation and fans i/c compound lights, repair maintenance of of dg set, pump sets of cbi quarters, cp block at salt lake, kolkata during the year 2025-26.(sh: supplying & laying xlpe insulated cable , supply, installation, testing and commissioning of led street light & pole box and ancillary works.)
Tender For supply of item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall diameter (mm) /- 2.0 15 max. safe pulling tension lo
Tender For corrigendum : tender for supply of submersible dewatering pumps : : - supply of impeller for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of pump shaft for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of siemens make dol starter for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of bearing (top bearing & main bearing )for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of mechanical seal ( upper & lower ) for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of cable gland sealing compound for kulkarni make dewatering pump having model no.(ks2315 , 1.5 hp) , supply of impeller for kulkarni make dewatering pump having model no.(ks2430 , 3 hp). , supply of pump shaft for kulkarni make dewatering pump having model no.(ks2430 , 3 hp) , supply of siemens make dol starter for kulkarni make dewatering pump having model no.(ks2430 , 3 hp) . , supply of bearing (top bearing & main bearing ) for kulkarni make dewatering pump having model no.(ks2430 , 3 hp) , supply of mechanical seal ( upper & lower ) for kulkarni make dewatering pump having model no.(ks2430 , 3 hp) , supply of impeller for kulkarni make dewatering pump having model no. (ks2550 , 5 hp) , supply of pump shaft for kulkarni make dewatering pump having model no.(ks2550 , 5 hp). , supply of siemens make dol starter for kulkarni make dewatering pump having model no.(ks2550 , 5 hp). , supply of bearing (top bearing & main bearing )for kulkarni make dewatering pump having model no.(ks2550 , 5 hp). , supply of mechanical seal ( upper & lower ) for kulkarni make dewatering pump having model no.(ks2550 , 5 hp). , supply of cable gland sealing compound for kulkarni make dewatering pump having model no.(ks2550 , 5 hp).
Tender For supply of as per boq d d - main lt panel indoor type with fp ai high safety mode technology , apfc capacitor panel 1250 kvar indoor type with aluminium tp , vacuum circuit breaker panel 11 kva 800 amp and vcb panel , transformer 3500 kva input voltage 11 kv output voltage 415 v , earthing arrangement copper plate earthing with 50 kg of chemical earthing transformer - 3500 kva technical specification- 1- capacity : 3500 kva, 2- input voltage : 11 kv, 3- output voltage : 415 v, 4- number of phase : 3 phase 5- applicable standard : standard, 6- number of winding : 02 nos, 7- installation type : outdoor, 8- cooling type : onan, 9- terminal arrangement : bare, bushing for hv side & 10- cable box for lv side., 11- vector group : dyn 11, 12- ambient temperature : 50 c, 13- temperature rise of oil : 40 c, 14- temperature rise of winding : 45 c, 15- impedance : 6.25% (subject to +/-10% tolerance), 16- transformer oil : "a grade" tested & certified as per is:335 standard., 17- no load losses : as per is standard, 18- full load losses : as per is standard, 19- copper : pure electrolytic grade, 20- tapping mode 01 nos - rotary type off circuit tap changer (octc) with locking arrangement & tap indication., 21- basic insulation leve for hv : 75 kv peak / 28 kv rms, 22- basic insulation level for lv : - / 3 kv rms, 23- tapping range +5% to -5% in steps of 2.5% by off circuit tap changer (octc)., (a) earthing arrangement (1) copper plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 10 meter with testing pit. (2) gi plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 4 meter with testing pit. (3) copper strips 50*6 (4) gi strips 50*6 make premium, (b) cables and accessories (1) 3 c x 240 sqmm al armoured ht cable (2) joint kit (3) 3.5 c x 400 sqmm al ) /bid number : gem/2025/b/6768705 * /dated: 17-10-2025 & & / bid document 1 / 19
Tender For corrigendum : supply of machine items fastenrs : : - pin dia 6x10 , mswire netting galvanised 70mm , sq hd scr m12x40 , conical seat 19 by 30 , bush , regulating valve g 3 by 4 inch , back nut p4x3 by 4 inch , slotted set screw flat point m12x12 , ss tube 4 by 3 , panel lock , key for panel lock , steel band