Get complete information related to latest Neonatal Probe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Neonatal Probe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Neonatal Probe Tenders.
Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : expression of interest (eoi) for market assessment of original manufacturers, authorized importers of equipments - multipara monitor icu ventilator biphasic detibrillator central monitor system for 20 bed multipara monitor central monitor system for 20 bed icu (1x20 multipara monitor) patient stretcher (fully ss) wheel chair foldable crash cart food step-double beside locker iv stand with ss rod and castor base biomedical waste small set of 3 dressing trolley dressing trolley ecg machine trolley instrument trolley oxygen cylinder trolley infusion pump ecg machine 12 channel abg machine with ise ion syrings pump bed side stool icu bed motorized with mattress overbed table intusion pump syringe pump abg machine with ise chesa inc iotome electric india pvt.ltd. x-ray machine 500 ma x-ray machine 300 ma x-ray machine 100 ma sonography machine ultraportable handheld digital x ray portable funds camera non. contact tonometer operating microscope rectam for pediatric screeing mobile x-ray syringe pump monitor pulse oximeter cpap pulse oximeter adult padiatric and neonatalprobes power bone drill pneumatic tourniquet cardiac cath lab with tumkeay handheld pulse oxymeter laparoscope non invensive ventilator pediatric dental chair wall mounted dental x-ray digital radiography with tumkey anesthesia workstation ventilator (adult+peed) ventilator (neonate) uv-visible spectrophotometer with attached cpu and printer ion selective meter (iono meter) wiith specific electrode quartz double ditillation unit soxhelet extraction unit (closed
Tender For supply of head up tilt test hutt , 10 multipara patient monitors with central monitoring station and remote viewing , ivus and nirs , high end echo machine with tee probe and 3d echo , pulsed field ablation console with 03 complete catheter kit , oct , orbital atherectomy - oad pump with 10 complete catheter kit , rota ablator , ambulatory blood pressure monitoring , treadmill test equipment , 48 hour holter machine , single chamber temporary pacemaker pulse generator , pft - pulmonary function test machine , 12 lead ecg machine , defibrillator , echo cardiography scanning machine (v2) (q2)
Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of ultrasonic testing probe and other spares requirements e e - ut probe for axial scanning on dia 50.00 mm and as per attached details. , ut probe for axial scanning on dia 67.25 mm and as per attached details. , ut probe for axial scanning on dia 79.00 mm and as per attached details. , ut probe for axial scanning on dia 100.00 mm and as per attached details. , ut probe for axial scanning on dia 114.00 mm and as per attached details. , ut probe for circum scanning on dia 50.00 mm and as per attached details. , ut probe for circum scanning on dia 67.25.00 mm and as per attached details. , ut probe for circum scanning on dia 79.00 mm and as per attached details. , ut probe for circum scanning on dia 100.00 mm and as per attached details. , ut probe for circum scanning on dia 114.00 mm and as per attached details. , cable-5 meter length, rg-174 type with connector to lemo-01 male and as per attached details. , cable-5 meter length, rg-174 type with connector to bnc type male and as per attached details. , cable-5 meter length, rg-174 type with connector to lemo-00 male and as per attached details.