Get complete information related to latest Neonatal Probe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Neonatal Probe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Neonatal Probe Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45736156 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of pressure gauge for d.a./lpg gas regulator, working pressure 0-2.5 kg/cm2, dial size 2 inch, with minimum 6 months warranty and valid calibration certificate from a government-approved/nabl- accredited laboratory. make: weldstar/esab/wika/ramco/techno or equivalent reputed brand. [ warranty period: 6 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45725358 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For tender for supply of laboratory consumables - bladder latex rubber-seamless, no-s, pinch cocks-hoffman's brass nickel plated, size: 18mm, aluminum foil,9mx30cmx10.smicron, ph indicator paper, universal, range:1-14, roll, vacuum grease, 50 gm tube, metroak 211, cotton roll 500 grm (packet), laboratory glass ware cleaning detergent neutral,5 ltr., whatman stnadard sheet,460 x 570mm, catno:1001918/sd f001wsso, merck: 10390013 in box of 500 sheet, whatman qunt.filter paper no.5 40, 11cm dia., cat.no.1540110, whatman qunt filter paper no.4 2, 15cm dia, cat.no.1442150, whatman qunt filter pape no.42, 11cm dia cat no 1442110, whatman qunt filter paper no1,15cm dia cat no 1441150, whatman qunt filter paper no.4 1,11cm dia, cat.nd 1441110, whatman qunt filter paper no4 0,15cm dia cat nd 1440150, whatman glass miro filter gf/y size 43mm, cat no 1825047 or equal pack of 100, whatman qualitative filter paper grace 2,120 mm dia, whatman glass micro filter 47mm catno 18218047,50 fofax c10,e-merex gf50/10428006,pkt. of 100 circles, whatman extr thimbles celluld se xsmmcat no.2800199, nylon membrane filter 0.22microns, 25mm dia, 100 nos/netcat no ny0225, membrane filter nylon 0.45microns 47mm dia, pack of 500 fisher no4sp 04700,cole farmer a02016-44, membrane filter millipore 45 microns, 25mm dia, haw p02500 (100 nos pet, cellulose nitrate filter, 5.0 micions 47 mm dia (pack of 1001, whatman 7195004 s&s or sartorious, cellinose nitrate membrane filtero 8mm 47mm dia in pack of 100 cmcles, cellulose acetate membrane fater paper, 0.2 um, 25 mm dia, cat no 1110 7025n, pit of 100, nylon membrane filter paper pour size o micron diameter:47 mmupack of 100, gridded surface membrane filtero 45mm white with blace gridded for microbiological analysis, p/n: 2355534 or equivalent, whatman g/c 1822-047 gmp 47mm 120m, syringe filter holder, 25mm p/n:16517-sortorius or equivalent, qualitative filter paper grade 4, dia 125mm whatman cat no:1004-125, glass fibre filter gf/a 13mm fit, whatman cat md 1820-8013, nitric acid 70%, 500 ml, hydrochloric acid-305,500 ml (trace metal grade) suprapure, merck cat no 1.00518-1000 equivalent

Central Government And Public Sector

CTN :45736604 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply, installation and demonstration of laboratory hot plate as per attached technical specification annexure-c. make- thermo fisher scientific, ika, velp scientifica, labtech or equivalent. [ warranty period: 24 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45709701 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of led weather proof 40 w surface/pendant mounting led tube fitting complete with corrosion resistant dust and water proof unbreakable polycarbonate body off white finish, frosted pc diffuser for glare free uniform light, protection-ip65, constant current above isolated driver, input voltage range 140-270v ac 50hz single phase with higher voltage auto cut off, pf- 0.95, thd<10%, colour temp. 5700k-6500k, view angle ? 120 degree, output lumens- 100 lm/w, cri>75, mini. efficacy of driver 85%, short circuit and open circuit protection mini surge voltage - 1.5 kv, led lm80/is:16105 test report support the same, driver shall comply the performance and safety requirement as per iec:62384/is:16104 & iec/61347-2-/61347-2-13/is:15885-2-13 with test certificate of nabl accredited laboratory shall be submitted, light source- smd type, brand/make- engraved/embossed minimum rep. warranty 03 years. make- jaquar, surya, bajaj, havells or equivalent. [ warranty period: 36 months after the date of delivery ] ]

CTN :45676692 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For purchase of fire safety and fighting laboratory equipment for fts department - purchase of fire safety and fighting laboratory equipment for fts department, cleveland open cup (coc) apparatus standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 c per minute (as per standard) temperature range: (-6 to 400) c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valve body: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hzsafety: overheat protection heat insulation, pensky-martens closed cup apparatus standard compliance: astm d93 / is 1448 (part 21) type: pensky-martens closed cup (motorized, digital type preferred) test cup: brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system: heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustableignition:pilot flame with automatic shutter mechanismtemperature measurement:thermometer or digital sensor (ip-28c or astm)digital temperature displaypower supply:230v ac, 50 hzsafety: over-temperature cut-off flame safety control

CTN :45676693 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For :purchase of chemistry laboratory equipment for basic engineering department - purchase of chemistry laboratory equipment for basic engineering department, hot plate: top plate material: cast iron ; plate size: minimum 8 inch diameter;power rating: 2000 w ; temperature range: ambient to 200 c minimumthermostatic temperature control: required; power supply: 220 240 v ac, 50 hz, ic regulated battery eliminator: ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., ammeter: dc (0 - 2 amp), voltmeter: dc voltmeter; range 10 v, analog, galvanometer: moving coil type, 30-0-30 scale, unbranded with bhel ; specification-sensitivity 0.143mm/v, water distillation unit: output capacity: 4 litres per hour (lph); ph value: 5.5 to 7.0 ; conductivity (raw water distillation):3.0 4.0 s/cm or less ; glassware material: borosilicate 3.3 glass (pyrex/duran equivalent); heating elements: silica-enclosed quartz heaters or chromium-plated element variants; power supply: 220 240 v ac,50 hz / 60 hz, single phase; automatic water level cut -off, electro analytical balance: load capacity: minimum 500 g; readability: 0.01 g; linearity: 0.02g; display: lcd/led; tare function: required; top pan type; power supply: 220 240 v; ac, 50 hz, electric bunsen burner: electrically operated, energy regulator/ control knob operating temperature 800 c ; body: stainless steel, power supply source: corded, electrically operated; energy regulator/ control knob, operating temperature 800 c ; body: stainless steel, power supply source: corded electric, supplied with a heavy-duty, heat-resistant, electric, supplied with a heavy-duty, heat -resistant, digital balance: weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led

Central Government/Public Sector

CTN :45698356 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of set of heavy-duty full gear flexible coupling with flange dia. 185 mm & pilot bore, material:en-9, die forging, hardness: 25-28 rc, coupling should be machine manufactured, with material & hardness test certificate from nabl/govt. approved laboratory. make: fenner/tss- s102 or equivalent reputed brand. (one set contains 2 nos. couplings) [ warranty period: 6 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

CTN :45540236 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For corrigendum : purchase of lab equipments for chemistry lab in basic engineering department - purchase, digital electronic balance /analytical balance load capacity: minimum 500 g readability: 0.01 g linearity: 0.02g display: lcd/led tare function: required top pan type power supply: 220 240 v ac, 50 hz, digital tds metermeasuring range: 0 9990 ppm resolution: 1 ppm display: lcd automatic temperature compensation (atc): required waterproof: minimum ip67 protection power source: battery operated (button cell/aaa battery), digital ph meter benchtop model ph type microprocessor/microcontroller ph range: 0 14 resolution: 0.01 ph accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibration facility temperature compensation type automatic display: lcd power supply: 220 240 v ac 50 hz warranty minimum 1 year, laboratory heating mantle (knitted glass yarn) capacity: 500ml temperature range: ambient to 350 c energy regulator/control knob: required power supply: 220-240 v ac 50 hz, electric bunsen burnerelectrically operated energy regulator/ control knob operating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant, earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220-240 v ac 50 hz, water distillation unitoutput capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0 conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material: borosilicate 3.3 glass (pyrex/duran equivalent) heating elements: silica- enclosed quartz heaters or chromium-plated element variants power supply: 220 240 v ac 50 hz / 60 hz, single phase automatic water level cut-off

CTN :45383075 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For corrigendum : expression of interest (eoi) for market assessment of original manufacturers, authorized importers of equipments - multipara monitor icu ventilator biphasic detibrillator central monitor system for 20 bed multipara monitor central monitor system for 20 bed icu (1x20 multipara monitor) patient stretcher (fully ss) wheel chair foldable crash cart food step-double beside locker iv stand with ss rod and castor base biomedical waste small set of 3 dressing trolley dressing trolley ecg machine trolley instrument trolley oxygen cylinder trolley infusion pump ecg machine 12 channel abg machine with ise ion syrings pump bed side stool icu bed motorized with mattress overbed table intusion pump syringe pump abg machine with ise chesa inc iotome electric india pvt.ltd. x-ray machine 500 ma x-ray machine 300 ma x-ray machine 100 ma sonography machine ultraportable handheld digital x ray portable funds camera non. contact tonometer operating microscope rectam for pediatric screeing mobile x-ray syringe pump monitor pulse oximeter cpap pulse oximeter adult padiatric and neonatal probes power bone drill pneumatic tourniquet cardiac cath lab with tumkeay handheld pulse oxymeter laparoscope non invensive ventilator pediatric dental chair wall mounted dental x-ray digital radiography with tumkey anesthesia workstation ventilator (adult+peed) ventilator (neonate) uv-visible spectrophotometer with attached cpu and printer ion selective meter (iono meter) wiith specific electrode quartz double ditillation unit soxhelet extraction unit (closed