Get complete information related to latest On Load Tap Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic On Load Tap Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding On Load Tap Changer Tenders.
Tender For corrigendum : research based pilot project [dynamic feeder voltage manager (dfvm)] for turnkey based work of design, development, supply, installation, testing & commissioning of 3-ph, 50 hz, 4000 kva, 12/12kv outdoor onan auto/power transformers equipped with on-loadtapchanger (oltc) with necessary infrastructure and protections, master controller and around 100 modems, control circuits with comprehensive maintenance contract for 05 (five years) after handing over the project
Tender For supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off loadtapchangeron ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For providing of operation and maintenance power house / power plant - carried out in connection with complete overhaulingof 15mva, 15.75/6.9kv uat-10a & 10b along with onloadtapchanger of 200mw unit no.10
Tender For auction sale of depot non ferrous scrap - p.l no: 98230013. scrap aluminium ingot in pieces consisting of scrap aluminium (with or without ferrous, rubber/plastic/ fiber and other than non-ferrous brass attachment) light fittings, window frame, stick, dj controller, fan blade, co2 box of wap -7, c3w, c2w, air flow, air dryer, air filter, anti-wind clamp, window shutter, levelling valve and duplex valve, air filter frame for lhb coaches, and miscellaneous aluminium parts, door closure, horn, prv, wiper motor, servo motor, end cover impler, mcp, panel board, different s valve, piston, motor blower cover, coupler, windscreen frame, hpmv & hpsv & mh fittings.qty-8000 kg. location- adjacent the south wall of ncb-6. custodians lot no. 03/09/june/2026-27/24. condition- weighment may be done at 50-ton weighbridge. loading of the materials will be performed by railway labourar.
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt
Tender For conversion of existing 50 mva, 220/33kv off loadtapchanger (+7.5% to - 7.5% in 7 equal steps) into onloadtapchanger (+5% to -15% in 16 equal steps) required for switchyards of takari lift irrigation scheme stage-ii. (total 1no.)
Tender For corrigendum : providing services overhauling and testing of on-loadtapchanger (oltc) make ctr and high voltage circuit breaker on-site at hbl plant sugauli