Web Analytics Made Easy - StatCounter

Organic Solvent Tenders

Get complete information related to latest Organic Solvent Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Organic Solvent Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Organic Solvent Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45672529 Due date: 10 Jul, 202610 Jul, 2026 1.50 Lacs
Tender For supply of lab chemical d d - basic lead sub acetate , organic solvent , bromo thymol blue powder , conc sulphuric acid , conc hydrochloric acid , sodium hydroxide , phosphoric acid , potasium per magnet , dextrose glucose pure , commercial hydrochloric acid , brix hydrometer 0 bata 10 , brix hydrometer 10 bata 20 , tharmameter 0 bata 120 centrigrate , universal indicator bata 500 ml , thymol blue bata 100 ml , buffer solution 500 ml , fehling a solution 500 ml , fehling b solution 500 ml , p h indicator paper , electronic weighing scale 500 gram , beaker 100 ml , conical flask 250 ml , test tube small , test tube big , test tube stand , plastic bucket 7 point 5 ltr , filter paper 18 point 5 cm q , knife of rapipol extractor per set , wattman filter paper 46x57 , alumnium mug 250 ml , plastic bata steel small dise , oven , muricuric chloride , plastic cylinder 100 ml , plastic cylinder 500 ml , plastic cylinder 1000 ml , meashuring flask 250 ml

CTN :45384469 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For purchase of chemicals - purchase of chemicals, diluent for dna extractionsize 500mla diluent used in dna extraction is typically te buffer (10 mm tris-hcl, 1 mm edta, ph ~8.0) or nuclease-free water, used to dissolve and dilute extracted dna. tris maintains a stable ph, while edta chelates divalent cations (e.g., mg ), thereby inhibiting dnase activity and protecting dna from degradation. the diluent must be sterile and free of nucleases to ensure the integrity of dna for downstream applications such as pcr, sequencing, and cloning., luria bertani mediumsize 500gluria bertani medium is a nutrient-rich growth medium commonly used for culturing bacteria such as escherichia coli and agrobacterium tumefaciens. it contains tryptone (10 g/l), yeast extract (5 g/l), and sodium chloride (10 g/l), which provide essential nutrients, vitamins, and osmotic balance for bacterial growth. lb medium supports rapid cell growth and is widely used in molecular biology for cloning, plasmid propagation, and transformation experiments. for solid media, agar (15g/l) is added., chloroform (high analytical reagent grade) size 2.5lchloroform (high analytical reagent grade) is a high-purity organic solvent used in dna extraction, particularly in phenol chloroform methods, to separate proteins and other contaminants from nucleic acids. it enhances phase separation by forming a distinct organic layer, allowing dna to remain in the aqueous phase. due to its toxicity and volatility, it must be handled under a fume hood with proper safety precautions., depcsize 25mldepc is a chemical used to inactivate rnases in water and laboratory solutions, making them suitable for rna work. it modifies histidine residues in proteins, thereby deactivating rnase enzymes that can degrade rna. depc-treated solutions are typically incubated and then autoclaved to remove residual depc, ensuring they are safe for use in downstream applications such as rna extraction and cdna synthesis., tb green master mixsize 200rnxtb green master mix is a ready-to-use reagent used in real-time pcr (qpcr) for dna amplification and detection. it contains tb green dye (a double-stranded dna-binding fluorescent dye), dna polymerase, dntps, mg , and reaction buffer. the dye binds to amplified double-stranded dna and emits fluorescence, allowing real-time monitoring of pcr amplification. it is commonly used for gene expression analysis and quantification of dna., dna loading dyesize 10 inchdna loading dye is a solution added to dna samples before agarose gel electrophoresis. it contains tracking dyes (such as bromophenol blue and xylene cyanol) that allow monitoring of dna migration during the run, and a dense agent (such as glycerol or sucrose) that helps the sample sink into the wells. it may also include edta to protect dna from nuclease degradation., metaloopa metal loop is a reusable laboratory tool made of platinum or nichrome wire, used for transferring and inoculating microorganisms onto culture media. it is sterilized by heating in a flame until red hot before and after use to prevent contamination. it is commonly used in microbiology for streaking plates and handling bacterial cultures.

State Government

CTN :45285975 Due date: 28 May, 202628 May, 2026 1.21 Crore
Tender For providing and supplying modular furniture for newly constructed government school building at kachigam, nani daman. - civil works, providing supply and installation of corner sink table -size :-1100mm l x 1100mm d x 900mm hconstruction : floor based welded cabinet system having storage body should be flush face construction with intersection of vertical and horizontal members like lh and rh side panel along with front horizontal channel, back panel and bottom panel. it should be relocated anywhere easily as it is an independent unit. cabinet should of square non-sharp edge construction. doors should be assembled with ss-304 hinge assembly. removable back panel should be provided to easily access the service lines running behind the cabinet benches. intermediate horizontal channels should be provided between door and drawer. toe-space of 90mm x 90mm is provided at front-bottom side of cabinet. levelers are provided for easy leveling of welded cabinet. shelf should be eight-bend panel with 20mm height. drawer tray should be of single piece construction. drawer should be well supported on lh and rh ball slide suspension system. steel door and drawer front should be of double wall construction with sound dampening material filled inside. doors should be easily removable and hinges should be easily replaceable. knee space panel should be in 22 gauge , cabinets are tested as per sefa 8m standard from a sefa approved lab and also tested as per en 14727 from a third party testing agency having nabl accreditation. dimensions : w= 900 mm, d = 900 mm, h = 875 mm configurations: 1 shutter - 1 nos moc: mscrca: is 513 (1994) thickness: lh/rh side panels, shutter front, bottom panel, top front, drawer separator, shelf, alignment channel is of 1.2mm thk. removable back panel, shutter cover, fr. rack strip, top cover panel is of 0.8mmthk. finish: powder coating pure epoxy, thickness 40-50 microns , followed with 9 tank pre treatment process the thickness of powder coat should be 45-50 microns, which passes the test of salt spray for 1000 hours. it should have a high temperature withstanding capacity with excellent electrical insulation properties.the rear portion of above accessories which is in contact with live metal should be made from thermo set material which will not melt on heating.handle : anodized aluminum recessed-type, ctc: 160.0mm lock: units have a locking facility with 180 and 10 lever cam lock mechanism (except for sink and corner unit) hinge: ss hinge screw: ss 304.shutter : should be of twin-type construction with sound dampening effect using profill.shutter cover should be equipped with bump on for sound dampening. base moulding should be made of pvc with corner clips. ball slide: 500mm length shutter should have provision of roller catch.pp sink,polypropylene molded sinks: made up of 5 mm thick high density and elastic poly propylene with good resistance to organic solvents. sink - bowl size to be a minimum of (l x w x d) 560 x 355 x 300 mm.faucet - 3-way type faucet as per approved makeworktop : jet black granite: it should be 19mm (+/- 2mm) thick jet black granite worktop. the exposed edges of the worktop should be chamfered and smoothened. the bottom of the worktop should be polished and there should be a v-groove throughout the length of the exposed edges to protect the cabinets from coming in contact with the spillages. the overhang on the storage cabinet is 25 mm at the front side and 30 mm at the sides. the backing material used is a neoprene mat of 6 mm thickness. (make as per selection of architect or selection of higher authority), providing supply and installation of corner table - size 1100mm l x 1100mm d x 900mm hconstruction: floor based welded cabinet system having storage body should be flush face construction with intersection of vertical and horizontal members like lh and rh side panel along with front horizontal channel, back panel and bottom panel. it should be relocated anywhere easily as it is an indepe

Central Government And Public Sector

CTN :45282651 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For supply of degreasing solvent for removing grease, oil, dirt, and other organic matter from electrical motor windings, parts, equipment, machinery,etc
 Loading, Please wait...

Connect us via What's Up