Get complete information related to latest Overload Protector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Overload Protector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Overload Protector Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overloadprotector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overloadprotector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overloadprotector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For auction sale of depot miscellaneous scrap - ubl/gsd/b-0022/ electrical/26/b[pl no.98411019] condemned and un-serviceable electrical scrap consisting of reading light fittings, emergency light and fitting, cfl/fl fittings, air fittings, fl box type fittings, tail lamp fittings, sockets, socket control panel boards, tpic/dpic switch boxes, ballast, capacitors, avm, iron box, wooden switch board, suction apparatus with accessories, stabilizers, plb switches, tube light fittings, electrical parts covers, head light resistors, carbon brushes, holder and parts, revdel, head light dim resistor, different types of measuring/checking devices/instruments, tx rx coil, with cables, connection box, fuces, ignitors, hotoor for lc gate, head light switches, cab fans, grass/tree cutter, different types of lights and its fittings, connecting wires, ovpr,dsp, junction boxes, dfb, different types of switches, electrical equipment covers, smps parts, classification cover knife switch covers, plungers, 2*2lsed panel light fittings, terminals board assembly , rotary switches,& other parts, light mast fittings 400w , coolers, grinder, relay jack,timer relay,siemens relay and other realeated parts, street light, limit switches, mcb, pressure switches over voltage relay, wiper blades, ultrasonic flaw detector, gasoline run concrete machine, guard control switches, contactors, bracket holder junction boxes with wire attached, electronics spare parts, pcb board, transformer parts, motor releted parts led driver,door closer armature, alternators and starter parts ,street lights ,defferent types camera and spare parts radiator conteceetor or wing assembly head light , bulb fixing, cab fan, frames & buses and clamp, ivr, fuse alarm unit,solar panel coupler socket, other parts.wiper parts mh choke/copper blast ,ovpr 25k/4.5,and other electrical/electronical parts with or without ms/steel/aluminum/cables attached scrap. available under the custody of cdms/rs ward/gsd/ubl. note: bidder has to physically inspect the lot before bidding. location:- road no 02 block b bin no-022 gsd/ubl. remarks-. delivery should start from one end. no pick and choose allowed
Tender For auction sale of depot miscellaneous scrap - scrap and unserviceable condenmed electrical fitting item such as dbr (dymamic braking resistor) grid set box with copper bus bar, shorting plates and connection plate for bar with or without clamps in dismenteled and broken condition with different types of attachment such as copper, nickel, chromium and insulations etc. (qty approx)
Tender For auction sale of depot miscellaneous scrap - scrap and unserviceable condenmed electrical fitting item such as dbr (dymamic braking resistor) grid set box with copper bus bar, shorting plates and connection plate for bar with or without clamps in dismenteled and broken condition with different types of attachment such as copper, nickel, chromium and insulations etc. (qty approx)
Tender For 1.5 ton ac, inverter type split air conditioners suitable for operation on a/c supply single phase 50 hz 230v with hermetically sealed inverter compressor with air cooled condenser latest r410a/r-32 refrigerant fan motor, start & run capacitors, relay & overloadprotector internal unit with one indoor & one outdoor unit. the condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube and suitable capacity 3 core sheathed/ pvc copper cable and a battery operated wireless remote unit and outdoor stand. (detailed specification is as per enclosed spec copy) [ warranty period: 12 months after the date of delivery ]