Get complete information related to latest Pedestal Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pedestal Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pedestal Unit Tenders.
Tender For annual repair, maintenance and operation of electrical & mechanical services at ag (audit) and a&e office, ag motinagar colony & lyndhurst estate at shillong (meghalaya) during 2025-2026.(sh: supplying and replacement of old cubical panels and batteries of ag(a&e) shillong, meghalaya.
Tender For providing sitout to balcony, glass cubical to toilets and other allied works at dy finance dept residence c 26 at vasanthnagar quarters, bengaluru
Tender For bid to ras bid to ras supply of house keeping materials at iim bodh gaya - room washroom freshener r5 , wood cleaner polisher , urinal screen mat , dry mop large flat type big size , dry mop large flat type base only for big size refer sl04 , mop set large , hard broom , naphthalene cubical shape , toilet brush , toilet brush small basin cleaner , duster cloth , soft broom , acid dilute antibacterial stain removing corrosive agent anti greasing. , caustic soda powder bag , dustpan , bleaching powder powder bag , washing powder , glass cleaning duster , cobweb brush , air freshner hanging packets , hand wash with dispenser unit 200 ml detton savlon , toilet cleaner rim block , garbage bags size 42 x 48 inches 1pkt 10 nos , disposable mask , transparent clear empty water spray bottles 500 ml , 28x28 inches large cotton floor cleaning mopping cloth super absorbent white threads big in size , colin 500 ml , bee full body beekeeping sui , room freshner spray 220 ml , black hit spary 400 ml
Tender For custom bid for services - defect rectification of acsr 2 (south tower)-defect., in has reported that tracks are not available on display of acsr #2., defect identification., di for the same was undertaken on 13 jun 2025. it was found that the pedestalunit, was required to be replaced to rectify the defect., scope of work to undertake defect rectification., 1. spare part., the required pedestalunit for replacement will be provisioned by in on site. all other, components/ units of acsr #2 should be in place to operationalize the system., 2. manpower., three skilled technicians will be required to undertake the pedestal replacement work., one tower climber also needs to be available on site. the tower climber and two, technicians will be provisioned by hela., 3. material/ machinery., one overhead crane with a loading capacity of one ton lifting to a height of 35 mtrs is, required to undertake the work. the same will be provisioned by in., 4. tools and accessory., the following are required and will be provisioned by hela:-, (a) torque wrench, (b) level indicator, (c) eye hook -02, (d) two 50 mtrs rope, (e) silicon, (f) drill machine, (g) lubricant, (h) slings for lifting, 5. activity to be undertaken., the sequence of events for replacement of pedestalunit will be as tollows:-, (a) disconnect and remove all cables, wave guide ard units from the antennae assembly., (b) fitment of lifting eye hook on antenna and pass lifting slings to the eye hook. dismantle antenna from pedestalunit and keep it on even surface on, the ground with the help of overhead crane. special care is o be undertaken while handling waveguide., (c) hook on the pedestalunit on overhead crane and op an securing bolts, of pedestalunit. lift the pedestal and move to the ground with cap closed of all connectors., (d) hook up new pedestal and lift it to the tower top and w hen aligned with, the position of pedestal plate lower the pedestal on the plate and tight the nut, bolt with level indicator on top of the pedestal to confirm tht the same is at, zero level., (e) lift the antenna to the top of tower and fix it to the pede stal unit., (f) install all units of acsr on top of tower and fix connectors and waveguide to the antenna., (g) switch on power and carry out power checks and fo (hecks., (h) switch on the acsr server and carry out alignment of system to get the tracks appeared on the display., 6. safety., all man working on tower should wear safety belt, safety helmet and safety belt to be, tied on two rigid point at tower top. the man below tower for handlin activity should, wear helmet. the antennae assembly and pedestalunit should be se cured with twopoint safety rope while lifting and lowering the same to avoid any dan age to the man, and material view heavy wind, lifting jerk or swing of the crane sling., .
Tender For bid to ras providing ei and ei panels and misc work for 4g lab at rttc jaipur - group c wiring for light point , wiring for circuit or submain wiring of size 2 x 1.5 sq mm and 1 x 1.5 sq mm earth wire , wiring for circuit or submain wiring of size 2 x 2.5 sq. mm and 1 x 2.5 sq. mm earth wire , wiring for circuit or submain wiring of size 4 x 2.5 sq. mm and 2 x 2.5 sq. mm earth wire , wiring for light or power plug with 2x4 sq. mm frls , wiring for light or power plug with 4x4 sq. mm frls , supplying and drawing 2 x 1.5 sq. mm sizes of frls , supplying and drawing of 3 x 1.5 sq. mm sizes of frls , supplying and drawing of 4 x 1.5 sq. mm sizes of frls , supplying and fixing of 20 mm size of steel conduit , supplying and fixing of 25 mm size of steel conduit , supplying and fixing pvc batten or holder , supplying and fixing 2 ft 10 watt led , supplying and fixing 9 watt rechargeable emergency bulb , supplying and fixing modular blanking plate , supplying and fixing suitable size gi box with 3 pin 5 or 6 amps modular socket , s f of suitable size gi box with 6 pin 5 or 6 and 15 or 16 amps , supplying and fixing of 3 module 100 mmx75 mm size or modules gi box , supplying and fixing of 6 module 200mm x 75mm size or modules gi box , supplying and fixing 8 module 125mm x 125mm size or modules gi box , supplying and fixing 12 module 200mmx150mm size or modules gi box , supplying and fixing 15 or 16 amp switch modular switch or socket , supplying and fixing 3 pin 5 or 6 amp socket modular switch or socket , supplying and fixing prewired led based wall mounting , sitc of 36 w colour temperature corresponding to bright , sitc of 18 watt 1450 lumens surface mounting down lighter type energy efficient led , sitc of 400 mm sweep oscillating type wall mounted cabin fan , supplying and fixing of 4 way 4 plus 12 ways double door surfaceor recess mounting , supplying and fixing of single pole 5 amps to 32 amps , providing and fixing of 100 amp, 30ka, fp mccb , supplying and installing of 100 mm width by 50 mm depth by 1.6 mm thickness , supplying laying and fixing of 3.5 x 70 sq. mm xlpe power cable , supplying laying and fixing of 3.5 x 50 sq. mm xlpe power cable , supplying and making end termination with 3.5 x 70 sq. mm 38mm , supplying and making end termination with 3.5 x 50 sq. mm 38mm , sitc 415v 3 phase 50 hz 4 wire system sheet steel clad dust and vermin proof cubical , earthing with copper earth plate , providing and fixing copper strip in g i pipe , providing and fixing copper strip on surface or in recess , providing and fixing earth bus of copper strip on surface , earthing with g i earth plate , providing and fixing of lightning conductor finial , jointing copper or g i tape , providing and fixing g i tape , providing and fixing g i strip in g i pipe , providing and fixing g i strip on surface , installation of upto 2 tr capacity split ac units , pdg and fixing 1 by 4 inch dia copper refrigerant piping , pdg and fixing 5 by 8 inch dia copper refrigerant piping , provision of top up or additional charging of r-22 or 32 gas , s f suitable size ms stand for placement of split type ac outdoor unit , providing and fixing 20 mm dia heavy duty pvc pipe , supplying and fixing 25 amp moduler type starter , supplying and fixing of 3 x 2.5 sq mm pvc insulated and frls , s f of wall mount digital temperature meter , sitc of self contained drinking water cooler
Tender For miscellaneous civil works in humanities and social science dept. roof treatment, false ceiling, painting, aluminium sliding window etc, cubical partition in physics dept. and false ceiling in seminar room of mathematics dept. at nit rourkela.
Tender For hiring of diesel jeep having cubical capacity 1500 cc and above age less than 15 years with driver for the use of electrical section pala for a period of one year