Web Analytics Made Easy - StatCounter

Photo Fluorometer Tenders

Get complete information related to latest Photo Fluorometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photo Fluorometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photo Fluorometer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40841890 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For corrigendum : supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100

CTN :41107264 Due date: 08 Aug, 202508 Aug, 2025 NA
Tender For call for objection notice against procurement of hsl 25 hockey stick shape linear transducer

Central Government/Public Sector

CTN :41115720 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For supply of item 10 51011001100114 transducer position rh m 0600md60 1 a01 , item 20 51011009000258 temposonic mm rh m 0025m t10 1 s2g1100 , item 50 51011001100110 transducer position el stroke 350mm , item 60 51011001100109 transducer position el stroke 300mm , item 70 51011001100236 sensor tempo position rhm0400mr101a01 , item 80 51011009000280 temposonics e series voltage 24v dc , item 90 51011002000176 transducer linear mm ik4 a b 0750 e 1 , item 100 51011001100184 temposonic mm rhm2150mr021a01 mts system , item 110 51011001100185 temposonic mm rhm4650mr021a01 mts system , item 120 51011001100186 temposonic mm rhm0850mr021a01 mts

Central Government/Public Sector

CTN :40832013 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For corrigendum : valve check, clutch electric, transducer linear position, ahp assembly fr9e fr6b-imported

CTN :40881927 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For food processing / chemical laboratory equipment - food processing / chemical laboratory equipment, automatic fibre analyzer, automatic fat analyzer, automatic protein analyser, lovibond tintometer, ultrasonic milk analyzer (double sensor), cold press oil machine for edible oil, optical emission spectrometer, laminar air flow, ultrasonic probe sonoicator (for lab), micro processor colony counter, bomb colarimeter, homogenizer, microwave oven (laboratory), ph meter, do meter, conductivity meter, turbidity meter, kjeldahl digestion, vortex mixture, hot air oven (natural convection), photo fluorometer, abbe refractometer, anaerobic culture jar, muffle furnace, flame photometer, melting point apparatus, moisture analyzer, polarimeter, viscometer, autoclave, vacuum filtration assembly, fume hood, semi batch pyrolysis reactor
 Loading, Please wait...

Connect us via What's Up