Get complete information related to latest Photodiode Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photodiode Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photodiode Tenders.
Tender For corrigendum : labour work for monthly & bimonthly meter reading with hhe/gprs system for consumers under various sub division of botad division.
Tender For pro.the comp.billing system including com.opetr at every billing center collecting the meter reading with means of digital camera, data enery of meter reading,printing of processed bill and same distributing to consumer within specified thetime limit
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
Tender For corrigendum : 15/2025-26 purchase of uhwc - नागरी आरोग्यवर्धिनी केंद्राकरिता (uhwc) आवश्यक असलेले साहित्य खरेदी करणेबाबत…(estimated rate) - corrigendum: 15/2025-26 purchase of uhwc - nagari arogyavardhini kendrakarita (uhwc) regarding purchasing necessary literature…(estimated rate) - (uhwc) (estimated rate), bucket big virgin plastic 16 lit make- madware/milton/jayo, bucket small virgin plastic 7 litmake- pavan/madware/jayo, swing dustbin square - 30 lit foot operated- red, blue, yellow & black colourmake-nacoda/polywell/ kyrace, swing dustbin 80 lit - round shape with lid red, blue, yellow, white & green colourmake-pavan/ratan/jayo, dustbin 60 lit - round shape with lid red, blue, yellow, white & green colourmake-pavan/ratan/jayo, plastic dustbin pedal - 10 lit foot operated- blue, red &yellow colourmake-pavan/joyo/nil kamal,, 3 bucket mop wringer trolley - 20 lit bucket each with (3 bucket wringer trolley bucket system for cleaning for hospital with included cotton wet mop refill (350 gm) clip - 60 ltr, red, blue, yellow, gray, plastic), wet mop - 6" 350 head, looped-end white cotton, ss handle make-gala/scotch-brite/joyo, , dry mop - 18" 360 degree rotate make-gala/joyo/roots, garbbage bag 19*21 - 50 micron, black, red, yellow, blue, green & white colour-1kg packet, hard broom weight 230 grams, soft broom make-gala/homeor/bbt, plastic supali weight 10 grams make-gala/milton/flair, mackintosh hospital sheetsize: 4 feet * 5 meter) material: water proof rubber colour: pink, blue, cotton hand towel 40*60 cm 400 gsm white colour (bombay dying)size:40cmx60cmweight:400gsm,100% cotton terryfeatures: double-stitched hems, bleach-resistant, suitable for frequent high-temp washes, chlorine tablet active ingredient: sodium dichloroisocyanurate (naddc) in anhydrous or dehydrate form.available chlorine: must release 45mg to 75mg of available chlorine per tablet (suitable for treating 20l of clear water)compliance: must strictly comply with is 9825:2003 or is 15773:2008, salt iodine test kit purpose: to monitor iodized salt quality under the national iodine deficiency disorders control programme (niddcp).methodology: starch-based liquid reagent (solution a& b) for colorimetric reactionmeasurement range: semi-quantitative detection at 0,7,15, and 30+ppmcapacity: minimum 100 tests per kitcontents: 2x dropper bottles, 1x laminated colour comparison chart,1x marathi/english instruction manual.compliance: must meet niddcp guideline for field testing., reusable cotton bed sheet for examination table- (size- 36 inch*84inch white colour), cleaning detergent powder 1kg packetmake-nirma , wheel, rin,, dry cell battery (1.5v)type; primary (non-rechargeable) alkaline or zinc carbon.size: aa, aaa, d.features; guaranteed leak-proof, long shelf life, clear expiry marking., torch ordinary rechargeable light source: 1.5w-3w led (>100 lumens)battery: li-ion or life po4 (min 1200mah).backup: 4-6 hrs continuous.charging: usb type-c or ac adapter.body: impact-resistant abs plastic., snellen vision chart-marathi language chart testing distance: calibrated for 6 meters (20 feet). acuity range: 6/60 to 6/6 (20/200 to 20/20 equivalent). material: high-grade, non-tearable pvc or acrylic (min 3mm). finish: matte/non-glare to meet nqas illumination standards. features: integrated red/green bars for duo chrome testing. language: standard marathi (devanagari) optotypes., near vision chart -marathi language chart language: specifically printed in marathi (devanagari script). notation system: dual notation featuring jaeger (j1 to j18) and n-point (n5 to n36) scales. testing distance: calibrated for a standard reading distance of 33 cm to 40 cm. material: high-grade, non-tearable pvc or heavy-duty laminated card (minimum 300 gsm). finish: matte/non-reflective finish to prevent glare from clinic lights. design: double-sided printing (side a: marathi paragraphs; side b: marathi isolated characters or english equivalent). dimensions: approximately 1
Tender For corrigendum : work of meter-reading monthly / bi-monthly spot billing system using android mobile devices (pda) for valsad east, valsad ind sub division under valsad city division.
Tender For corrigendum : work of meter-reading monthly / bi-monthly spot billing system using android mobile devices (pda) for nanakwada & atul sub division under valsad city division.
Tender For corrigendum : work of meter-reading monthly / bi-monthly spot billing system using android mobile devices (pda) for valsad west & coastal sub division under valsad city division.