Get complete information related to latest Photodiode Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photodiode Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photodiode Tenders.
Tender For supply of portable pa neckband system, rechargeable with 1 neckband mic with usb and sd card input, black, mp3 player, mounting type-neckband, power source- battery powered, connector type-usb, number of channels 2, audio input 3.5mm mic, 3.5mm line, output wattage-12 watts, item weight unit of measure 0.40 kg- 0.50 kg, built-in mp3 digital player for playback of music through a usb drive or a tf card; the unit can be used while hanging on the shoulder or by putting around the neck. ]
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For corrigendum : supply of equipment for mechanical engineering department - supply of equipment for mechanical engineering department, lathe machine :specification :bed: 2v & 2 flat, induction hardened and ground minimum bed length: 1375 mm bed width: 240 mm capacity: height of centre: 165 mm swing over bed: 320 mm swing over gap: 510 mm swing over cross slide: 180 mm distance between centres: 650 mm slides: cross slide travel: 200 mm compound slide travel: 115 mm spindle: spindle bore: 40 mm spindle nose: thread type, 62 mm spindle taper: mt-3 tail stock: quill diameter: 38.1 mm taper: mt-3 travel: 120 mm speed: no. of speeds: minimum 8 range: (40 800 )rpm threading: metric: (1 6 )mm (min 13 steps) english: (2 24 )tpi (min 19 steps) lead screw: (1 4) tpi electrical: motor: 1.5 hp, 230v/415v, 50 hz drive: v-belt structure: bed: close-grained cast iron (fg 260) gears: hardened steel base: rigid cast iron stand , open cup apparatus :specification :standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 6 c per minute (as per standard) temperature range: -6 to 400 c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valvebody: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hz safety: overheat protection heat insulation , closed cup apparatus :specification :standard compliance: astm d93 / is 1448 (part 21) test cup:brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustable ignition: pilot flame with automatic shutter mechanism temperature measurement: thermometer or digital sensor(ip-28c or astm) display: digital temperature display power supply: 230v ac, 50 hz safety:over-temperature cut-off flame safety control , tail stock assembly :specification :medium-duty tailstock assembly for dismantling & assembly quill stroke: minimum 75 mm taper: mt-3 (preferred standard) feed: hand wheel operated features: set-over screws for taper turning spindle locking arrangement body: cast iron (fg 260) spindle: hardened steel, slip gauge :specification :set size: m87 (87 pieces) or equivalent range: 1.001 mm to 100 mm step sizes: 0.001 mm 0.005 mm 0.01 mm material: high-grade alloy steel / tungsten carbide (preferred) hardness: hrc 63 65 accuracy: grade: grade 1 or grade 2 flatne flatness / parallelism: 0.5 m stored in protective wooden boxes to prevent wear; calibration grades include charts for exact sizes , dc motor:specification :type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel calibration grades include charts for exact sizes supply: mounted on training base suitable for dismantling and inspection , hydraulic operated directional control valves (dcv):specification :type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study , bearing with shaft assembly :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steelsupply:mounted on training base suitable for dismantling and inspection , coupling unit using
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For bid to ras bid to ras supply of display unit , round photodiode energy sensor (a) , round photodiode energy sensor (b) , pyroelectric laser energy sensor
Tender For purchase of equipment for the department of physics--- weight box (gm weight & milligram weight), simple pendulum (bob), young modulus, voltmeter (0-10 volt dc), galvanometer (0-30), voltmeter dc (0-3 volt), battery eliminator (power supply, dc output, 2-12 vol 750ma), post-office box, tangent galvanometer (50 turns coil), spherometer, led and laser diode characteristics apparatus, hybrid parameters of transistor, tomcats pendulum , bar pendant , damping oscillation in various mediums , thermal expansion apparatus , reported apparatus , archimedes principle apparatus , biot-savart law apparatus , photodiode characteristics apparatus , ldr characteristics apparatus, tunnel diode characteristics apparatus, rc coupled amplifier kit, rc phase shift oscillator using opamp, deflection magnetometer set, opamp kit, surface tension by capillary rise, co-efficient of viscosity by poiseuille's method., co-efficient of viscosity by stokes law with photogate, lcr series resonance apparatus, lcr parallel resonance, spring constant set, laser red for diffraction, laser green for diffraction, laser violet blue for diffraction, grating with different grating constant, vibration magnetometer, hall effect apparatus, bh curve tracer, quincks method, piezoelectric transducer kit, mercury lamp, fresnel's biprism diffraction apparatus, bread board with power supply, balmer series and rydberg constant set up, hydrogen discharge tubes for the rydberg constant set up, mercury lamp, michelson interferometer with light source, fresnel bi-prism complete set-up with sodium source, set-up for millikan's oil drop experiment, set-up for de-broglie wavelength. measurement, zeeman effect, lattice parameter se, electron spin resonance , fourier analysis kit , microwave bench set up