Get complete information related to latest Pipe Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipe Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipe Valve Tenders.
Tender For on risk & cost piped water supply scheme for village- kodwa (bathanpara, nityatola, sarnapara, thanpara, tilapara) block- sankargarh district balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 40 kl capacities 02 no. & staging 12 mtr& 80 kl capacities 00 no. & staging 12 mtr {steel structure 12 m height & 10 kl (5000l x 2no.) 00 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 100 m & 63 mm dia 0.00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 4220 m., 75 mm dia. 2320 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4/6 tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 170 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water supply scheme under jal jeevan mission for on risk & cost piped water supply scheme for village- kodwa (bathanpara, nityatola, sarnapara, thanpara, tilapara) block- sankargarh district balrampur(c.g.)
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- lau(baigapara,dhamdhamiyapara,joblapara,parsapara,ghutrapara,mudrapara,mahuwapara) block-rajpur district balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 45 kl capacities 01 no. & staging 15 mtr& 80 kl capacities 01 no. & staging 12 mtr {steel structure 12 m height & 10 kl (5000l x 2no.) 03 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 2221 m & 63 mm dia 0.00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1327 m., 75 mm dia. 0 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4/6 tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 27 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water supply scheme under jal jeevan mission for village- lau(baigapara,dhamdhamiyapara,joblapara,parsapara,ghutrapara,mudrapara,mahuwapara) block-rajpur district balrampur(c.g.)
Tender For repair maint of external water supply system incl repair/replacement of unserviceable pipelines valves valves pit chamber various motor pump set cleaning of sumps ro plant and other connected work at shakurbasti and hirankudna under ge north
Tender For supply of bearing bush de and nde part no fm590bd220958642044 , balance valve part no fm590bd220958642033 , larger seating and bush for delevery cover part no fm590bd220958642031 , neck bush part no fm590bd220958642021 , shaft sleeve de part no fm590bd220958642010 , water seal ring split type part no fm590bd220958642009 , split gland part no fm590bd220958642007 , shaft sleeve nde part no fm590bd220958642037 , sleeve nut de part no fm590bd220958642059 , sleeve nut nde part no fm590bd220958642038 , counter sunk screw part no fm590bd220958642032 , pump shaft part no fm590bd220958642002 , wearing ring casing part no fm590bd220958642012 , combined diffuser and return vane part no fm590bd220958642017
Tender For supply and application of insulation materials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulation material is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermal insulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulation material : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulation material : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00 inches; thickn
Tender For corrigendum : general klc section 2 running contract urgent repairs in the existing pipes valves and other allied works at klc campus garden for the period of first half of 2025