Web Analytics Made Easy - StatCounter

Pipe Valve Tenders

Get complete information related to latest Pipe Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipe Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipe Valve Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45743518 Due date: 21 Jul, 202621 Jul, 2026 37.66 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)

State Government

CTN :45743537 Due date: 21 Jul, 202621 Jul, 2026 10.72 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45738325 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For supply of oil filter element , fuel filter element , hose coolant pipe , hvac filter , pin for release lever , hydraulic pipe , valve plug , gear shift lever , air tank pipe line , fuel pipe line , hinges assy

CTN :45720895 Due date: 01 Jul, 202601 Jul, 2026 25.00 Lacs
Tender For annual rate contract for annual maintenance and spare parts supply work of jcb machines. - cylinder liner, over haul gas kit, valve inlet exhaust, crank shaft, main bearing set, trust washer, piston, piston ring set, diesel main pipe, diesel filter pipe, thermo state elbow, air cleaner hose, diesel pump repair with parts, thermo state valve, connecting rod, con. rod bearing set, cam shaft bush, rocker arm, rocer arm shaft, gear cam shaft, water pump assy., oil pump assy., oil filter, belt, engine mount pad, exhaust elbow, engine throttle cable, engine stop cable, turbo charger assy., silencer exhaust abi, flang exhaust, element main, element secondary, auto tensioner, idler gear, engine fan, fuel filter assy., filter kit, engine connecting rod, fan drive puley, hyd. strainer, suction strainer, fuel injection pump, injector pipe, rubber hose, fuel filter assy., nozzle, return line, fuel module with sensor, fuel tank cap, fip repair with parts, radiator, radiator assy., coolent, hose top, hose cac (cold side), hose cac (hot side), radiator solding, front grill, front grill lock, front wheel and axle, axle service, center pin, axle stub, hub, hub stud, hub seal, seal cone, bearing inner, bearing outer, axle carrior l/h, axle carrior r/h, track rod, brake fri. plate, brake cou. plate, brake seal, brake oil 500ml, differential, differential gear planet, gear planet, bearing roller double, seal cassetle, bearing teper, tripling seal, stud wheel, carrior innulus, gear innulus ring, hub palentry, drive shaft, bearing roller, bearing teper roller, yoke, cross patti & bolt, cross holder, uj cross, bearing, brake, master brake cylinder, pipe brake l/h, pipe brake r/h, brake reserver, steering, coupling, bearing, rim steering wheel, self starter, self starter, solenoid, switch altinator, altinator puley, wheel belt 1232, rocker plate, field set, armature bush set, bearing assy., carbon set, bendex, armature, armature bush set, altenator, starter, cut out, rectifier plate, bearing, bearing plate, rotor, terminal, wiring and electrical, wiring harness complete, bettery cable, hour meter, head light bulb, tail light bulb, fuse and reley 15 amp, tail lamp, head light assy., ignition switch, wiper blade assy., harness roof, combination switch, fog lamp, body, side mirror, seat, wiper motor assy., wiper blade, catch window, latch l/h, wind screen front, glass outer l/h, glass outer r/h, rear window glass, door soccker, door hinge, lock set inner, lock set outer, door got set, door belt, transmission, transmission over, charging pump assy., counter plate, firction plate, transmission filter, bearing, bearing, torque converter, bearing, converter, drive plate kit, mounting, yoke coupling, lever assy. gea turret, selonoid valve assy., strainer, transmission filter, stabliser, steblizer piston, steblizer rod, inner leg steblizer, steblizer foot, pin pivot, adjuster, atb rear pad kit lower, atb rear pad kit upper, hydraulic, ind. steering suct, selonoid coil, hyd. filter assy., hyd. filter element, mrv, hyd. pump, repair kit, priority valve, ram seal, pump seal kit, pump steering, ramp bucket, ramp bucket, ramp bucket, ram, bucket lift cylinder ram, bucket tilt cylinder ram, boom ram, loader ram, loader jaw ram, dipper ram, slew cylinder ram, stablizer ram, steering cylinder ram, 6 in 1 ram, hose, hose-10-bsp 560mm, hose-08-bsp 1860mm, hose-10-bsp 2750mm, hose-04-10bsp 1825mm, hose-08-bsp 2620mm, hose-10-bsp 2520mm, hose-08-bsp 2860mm, hose-08-bsp 2650mm, hose-12-bsp 3900mm, pin and bush, bucket pin, pin, pin, tipping lever, pin dipper, bush, bush, pin, boom main pin, pin, pin top, pin pivot, pin pivot, pin boom ram, pin pivot, pin pivot, pin pivot, kpc kit and bush, bucket kit, seal kit, bucket seal kit, dipper seal kit, boom seal kit, seal slew kit, s t b, steering seal kit, loader seal kit, lift seal kit, bucket seal kit, rubber seal kit, boom seal kit, s t b kit, slew seal kit, loader seal kit, steering seal kit, loader and bucket welding, l

CTN :45716749 Due date: 08 Jul, 202608 Jul, 2026 50.0 Thousand
Tender For supply of tata safari compressor and ac gas pipe repair , ciaz wiper blade motor repair , fly wheel skimming of tata 2.5 ton , repair of pressure valve of tata 2.5 ton , repair of re piston head injector nozzle

Central Government/Public Sector

CTN :45703692 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of screw compresor boq b b - air filter, part no. 39588777 , coolant filter element, part no. 39907175 , separator element, part no. 54595442 , blowdown solenoid valve, part no. 22124085 , kit high air temperature switch, part no. 37952264 , minimum pressure check valve, part no 70662416 , temperature sensor, part no 37952439 , v belt, part no 54524343 , gas spring, part no 39592951 , element thermo valve, part no 39441944 , inlet valve, part no 39840418 , shaft seal kit , part no 42486597 , kit unloader repair, part no 42385948 , belt, in 15 by 7 bar, part no. 54400726 , element separator, part no. 22388045 or 24121212 , element oil filter, part no. 39329602 , element air filter , part no. 88171913 , elbow 1by4 inch bspt x 6mm, part no. 54403266 , kit rebuild mpcv, part no. 18983262 , kit inlet valve rebuild sd, part no. 18983700 , switch pressure 7 bar in 7.5-15, part no. 70278999 or 23672744 * /bid number : gem/2026/b/7714185 + /dated: 26-06-2026 ' ' / bid document 1 / 24

State Government

CTN :45707196 Due date: 10 Jul, 202610 Jul, 2026 3.80 Lacs
Tender For comprehensive operation & maintenance of civil & electromechanical assets such as intake wells/structures, hglr, sump, presser filter plant , staff quarters, pump house, all bulk transmission and distribution pipelines, valves, pumping machinery & electrical equipment etc. for the jamanyamal regional water supply scheme, including supply of 0.32 mld potable water to all the, 04/villages, 0/habitations for 06-months period. taluka: subir , district: dang based on dams at headworks excluding supply of bleaching powder &water and energy charges.

State Government

CTN :45707204 Due date: 10 Jul, 202610 Jul, 2026 3.72 Lacs
Tender For comprehensive operation & maintenance of civil & electromechanical assets such as open wells,hglr, sump, staff quarters, pump house, all bulk transmission and distribution pipelines, valves, pumping machinery & electrical equipment etc. for the girmal reg.water supply scheme, including supply of 0.24mldportable water to all the, 03 villages, 06 months period. taluka: subir,district : dang based on open wellexcluding supply of, bleaching powder and pac solution, water and energy charges. at various villages of subir taluka of dang district.
 Loading, Please wait...

Connect us via What's Up