Get complete information related to latest Pipes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipes Tenders.
Tender For corrigendum : this work is for construction of parapet, platform around sources etc and ground water recharge pit, supply and fixing gutter pipe and 75mm upvc pipes for collecting water from the roof top, down pipe for flushing out first flow water, scour pipe etc
Tender For supply of airconditioning work at sbi rbo5 basti under administrative office gorakhpur d d - supply of cassette ac, 4.0 tr single phase only bee 5- star inverter ac , supply of hi-wall split ac, 2.0 tr bee 5- star inverter ac , installation of 4.0 tr cassette ac , installation of 2.0 or 1.5 or 1.0 tr hi-wall split ac , supply and installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 4.0 tr cacs , supply and installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 2.0 or 1.5 sacs , supply and installation of interconnecting wires for 4.0 tr cassette acs , supply and installation of interconnecting wires for 2.0 or 1.5 tr hi-wall split acs , supply and installation of 25 mm pvc drain pipes with insulation , supply and installation of ms angle for outdoor units , supply and installation of 4.0 kva stabliser having copper winding with voltage range of 130 - 280v , supply and installation of 5.0 kva stabliser having copper winding with voltage range of 130 - 280v , dismantle shifting and reinstallation of old existing 2.0 or 1.5 or 1.0 tr hi-wall
Tender For अधिषाषी अभियंता-प्रथमके क्षेत्राधिकार में आर.सी.सी. (np-03)पाईप डलवाने का कार्य। -work of laying rcc (np-03) pipes under the jurisdiction of executive engineer-i.
Tender For construction of approach path to special repair complex at akramabad, p/walls for strengthening twinline g/ main, replacement of old defective mech. parts at different structures (filter plant and gsr), providing and laying of d.i pipes at various spots of twin
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p