Get complete information related to latest Pole Structure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Structure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Structure Tenders.
Tender For corrigendum : repair, maintenance and servicing of ht eqpts including transformer, vcb, rmu and ht cables, 2/4 polestructure under ge nasik road camp
Tender For supply of antique light pole with two diffuser led light with 3.7 mtr long material cast iron and ms , xlpe insulated pvc sheathed fr-lsh armoured str. al conductor cable 4 core 16 sq mm 1.1kv grade , led modern outdoor wall light 12watt , single pole mcb c series 6 a 240 v 50 hz 10 ka , digital timer time switch for 24 hrs , laying of power cable in ground including excavation and refilling , erection of polestructure
Tender For supply of 7150469333 copper rod of 5mtr length refer tender for tech specs , 7108360153 10 mm ss bolt 50mm long nut, bolt and washer refer tender for tech specs , 7790380043 ryb heat shrinkable sleeve 60 by 10 - 10 mtr each refer tender for tech specs , 7508950903 isolator,air break switch voltage 11 kv refer tender for tech specs , 7150469953 air break switch, female contact refer tender for tech specs , 7508108513 earthing mouths for 11kv ab disconnecting switch feeders refer tender for tech specs , 7135980773 epoxy support insulator,11kv refer tender for tech specs , painting of 11kv 4 polestructure refer tender for tech specs , charges for erection of 11kv ab switch refer tender for tech specs , replacing spares of 11kv structure refer tender for tech specs
Tender For corrigendum : repair/ replacement of ht ug cables, god, 11 kv ht oh line, 4 polestructure and maint of distribution transformer, ht switchgears and other connected works at mil yol stn under ge(kh) yol.
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four polestructure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49
Tender For corrigendum : upgradation of ht 11 kv two polestructure to vcb at at sub station no 09 including connected work under ge dssc welington - name of work: upgradation of ht 11 kv two polestructure to vcb at at sub station no. 09 including connected work under ge dssc welington
Tender For corrigendum : repair/replacement of insulators/ht vcb/rmu panels/maintenance of transformer and two polestructure and earth pits and allied works at af stn mothala under ge (af) naliya
Tender For supply, erection, testing and commissioing of 100kva transformer on double polestructure with allied electrical work for msetcl 132 kv switch yard under mokhabardi lift irrigation scheme.
Tender For corrigendum : repair replacement overhead, two pole four poles structure, grass cleaning, la earthing, barracks and other connected items at mil stn gaya