Web Analytics Made Easy - StatCounter

Pole Structure Tenders

Get complete information related to latest Pole Structure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Structure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Structure Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45313954 Due date: 20 Jun, 202620 Jun, 2026 44.00 Lacs
Tender For corrigendum : special repairs to 2 / 4 pole structure including connected works at certain locations at afa hyderabad

State Government

CTN :45261763 Due date: 15 Jun, 202615 Jun, 2026 70.00 Lacs
Tender For corrigendum : supply of carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri

State Government

CTN :45261767 Due date: 15 Jun, 202615 Jun, 2026 76.00 Lacs
Tender For corrigendum : supply of stay rod 20x1800 mm, etc material from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr rabbit conductor from esc mnp , carriage of acsr weasel conductor or insulated conductor as provided by department from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x185 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv straight through size 3x185 sq.mm. from esc mnp , carriage of 11 kv vcb for og ctr 200by100by5a 350 mva 1250 amp. from esc mnp , carriage of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. from esc mnp , carriage of g.i. wire 6or8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of l.t. fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr rabbit conductor , laying of acsr weasel conductor or insulated conductor as provided by department , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure , erection of single pole structure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line with gaurding angel etc , fencing of distribution transformers , make plinth for 250 kva transformer proper size as per resspo norms , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 11 kv xlpe cable 3x185 sq.mm. , laying of 11 kv xlpe cable 3x300 sq.mm. , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv straight through size 3x185 sq.mm. as per norms. , installation of 11 kv vcb og ctr 200by100by5a 350 mva 1250 amp. , installation of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. , dismentlling of old and damaged cable of different size , received back of distribution transformer after increasing capacity

State Government

CTN :45282107 Due date: 15 Jun, 202615 Jun, 2026 63.00 Lacs
Tender For corrigendum : supply of supply of 11 kv v type cross arm clamp , supply of 3 phase dis. box clamp with nut and bolts , supply of connecting cable , supply of l.t. fuse set protection box , supply of tinned copper fuse wire different size , supply of hdpe pipe , supply of stone pad , supply of holding clamp , supply of ms angle , supply of t-off chhanel , supply of top chhanel 125x65x240 , supply of dropper channel 100x50x2028 mm. , supply of danger board with clamp and nut and bolt , supply of g.i. patti clamp nut and bolts , supply of l.t. tail less unit , supply of copper l-pieace , supply of 11 kv f clamp , supply of suspension clamp , supply of dead end clamp , supply of eye i hook , supply of eye bolts for guarding , supply of j hook , supply of lt clamp , supply of pearcing connector , supply of alluminium lug 120 sq.mm. , supply of alluminium lug 240 sq.mm. , supply of alluminium lug 70 sq.mm. , supply of nut bolts and washers off size , supply of guarding angel , supply of guarding angel clamp , supply of m.s. angel iron 65x65x6 mm. , carriage of 9 m stp pole-sp- 55 galvanised , carriage of 11 m stp pole-sp- 55 galvanised , carriage of 8.5 m pcc pole , carriage of v type cross arm for 11 kv , carriage of 11 kv pin insulator with pin , carriage of disc insulator with fitting t and c 45 kn , carriage of 11 kv fuse set , carriage of 11 kv tpmo with polymer insulator , carriage of complete stay , carriage of distribution transformer 25 kva , carriage of distribution transformer 63 kva , carriage of distribution transformer 100 kva , carriage of distribution transformer 250 kva , carriage of acsr dog conductor , carriage of acsr weasel conductor , carriage of m s earthing rod 20 x2540 mm , carriage of lt al. xlpe cable size 1x240 sq.mm. , carriage of lt pvc cable 1x120 sq.mm. for dtr , carriage of lt pvc armoured cable size 3.5x70 or 35 sq.mm. , carriage of 11 ) /bid number : gem/2026/b/7551524 * /dated: 20-05-2026 & & / bid document 1 / 54 kv xlpe cable 3x185 sq.mm. , carriage of lt ab cable 3x120 sq.mm. , carriage of lt ab cable 3x50 sq.mm. , carriage of lt ab cable 3x95 sq.mm. , carriage of lt pvc armoured cable size 4x25 sq.mm. , carriage of 33 kv xlpe cable 3x300 sq.mm. , carriage of 33 kv indoor or outdoor jointing kit , carriage of 11 kv indoor or outdoor jointing kit , carriage of 33 kv straight through , carriage of 11 kv straight through size 3x185 sq.mm. , carriage of 11 kv vcb , carriage of g.i. wire 6 or 8 swg for guarding , carriage of three phase distribution box , erection of l.t. fuse set protection box , execution of chemical earthing with g.i. patti clamp nut and bolts , execution of pipe earthing with g.i. patti clamp nut and bolts , erection of l.t. tail less unit with all respective material , laying of acsr dog conductor , laying of acsr weasel conductor , laying of lt ab cable 3x120 sq.mm. , laying of lt ab cable 3x50 sq.mm. , laying of lt ab cable 3x95 sq.mm. , mounting of 3 phase distribution box , erection of double pole structure , erection of single pole structure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of distribution transformers , plinth work , installation of transformers 11 or 0.4 kv t or f 25 kva , installation of transformers 11 or 0.4 kv t or f 63 kva , installation of transformers 11 or 0.4 kv t or f 100 kva , installation of transformers 11 or 0.4 kv t or f 250 kva , laying of cable 11 kv xlpe cable 3x185 sq.mm. , laying of cable 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit , installation of 11 kv indoor or outdoor jointing kit , installation of 33 kv straight through , installation of 11 kv straight through , installation of 11 kv vcb , dismentlling of jarjar g.i. wire and weasel conducter , received back of distribution transformer

Central Government/Public Sector

CTN :45491085 Due date: 07 Jul, 202607 Jul, 2026 1.25 Crore
Tender For repair, maintenance and servicing of ht eqpts including transformer, vcb, rmu and ht cables, 2/4 pole structure under ge nasik road camp

Central Government/Public Sector

CTN :45268989 Due date: 17 Jun, 202617 Jun, 2026 45.00 Lacs
Tender For corrigendum : repairs / replacement and maintenance to ht vcbs, cables, battery bank / charger, four pole structures, distribution transformers inlcluding allied works at aob rambilli

State Government

CTN :45495188 Due date: 16 Jun, 202616 Jun, 2026 1.32 Lacs
Tender For estimate for shifting 33 kv double pole structure near hanuman temple khalini under maintenance sub- division bharari shimla-1

CTN :45112925 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

Central Government/Public Sector

CTN :45475185 Due date: 29 Jun, 202629 Jun, 2026 40.00 Lacs
Tender For repair/ replacement of ht ug cables, god, 11 kv ht oh line, 4 pole structure and maint of distribution transformer, ht switchgears and other connected works at mil yol stn under ge(kh) yol.

Central Government/Public Sector

CTN :45447207 Due date: 26 Jun, 202626 Jun, 2026 11.00 Lacs
Tender For repair replacement overhead, two pole four poles structure, grass cleaning, la earthing, barracks and other connected items at mil stn gaya
 Loading, Please wait...

Connect us via What's Up