Get complete information related to latest Power Capacitor Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Capacitor Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Capacitor Bank Tenders.
Tender For supply of 25 kvar powercapacitorbank mpp heavy duty (box type) - 440v, 3 phase, 50 hz as per is no. 13340. makes/brands: schneider/legrand/c&s/l&t/abb/neptune power/havells/epcos only. [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc power supply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc power supply compact designeasy to operatethe instrument should have following technical specifications:dc power supply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc power supply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase power light indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: ac power supply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop
Tender For supply installation testing and commissioning of self healing mpp mp type shunt capacitorbanks for improving power factor to drainage pumping stations and sewage treatment plants in circle ii area
Tender For supply installation testing and commissioning of self healing mpp mp type shunt capacitorbanks for improving power factor to drainage pumping stations and sewage treatment plants in circle iii area
Tender For state plan- works under nedumkandam section-state plan 2024-25 - energy efficiency improvement, optimization of electromechanical items, safety audit and ensuring safety in operation of wtps and pump houses- rwss to udumbanchola - supply, e - cost of materials & working charges, od70149/2024-2025:1. pump & motor -supply, erection, testing and commissioning of kwa pre-qualified reputed make centrifugal pump set with bronze/ss impeller, ss shaft and ci pump casing etc. complete. the duty condition is as follows, discharge - 6 lps & total head - 92m, the motor is tefc squirrel cage induction motor suitable for the above pump working with 3 phase, 50 hz, 415 v shall confirm to eefi/is 325 etc. complete including providing suitable concrete foundation including cost of cement., sand and metal etc. flexible coupling shall be used for coupling of pumps and motors. 2. starter - supply, erection, testing and commissioning of suitable rating fullu automatic star delta starter with air break contact starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per ie rules and code of practice etc. complete. 3. panel board (suitable) for operating pump sets (but one pump set at a time) - supply, erection, testing and commissioning of cubical type floor mounted ms fabricated dust and vermin proof common control panel board consisting of 1 no. suitable capacity mccb as incomer and 2 nos of suitable capacity mccb as out going (the two mccbs are interlocking with each other) providing suitable size aluminium bus bar inter connect the above mccbs and fitted with 3 nos of indicator lamps, 1 no. volt meter with selector switch, 1 no. ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the mccbs as per ie rules and code of practice. the panel shall be fitted on a common base frame on suitable foundation. 4. cabling work - supply, laying, testing and commissioning of suitable size cables for the above pump set from panel board to starter and from starter to motor , considering energy conservation. 5 .earthing - supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing gi/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per ie standards. 6. capacitor - supply, erection, testing and commissioning of heavy duty app capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to is 2834 . 7. valves - supply of suitable size best quality heavy duty isi marked ci double flanged sluice valve and non return valve with suitable pressure rating 8. suction and delivery pipe connections - the size of the suction pipe is suitable as per the site condition with a max length of 7.5m. suitable size foot valve connecting at the suction pipe bottom etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.warranty 2 year (1 year warranty+ 1 year additional warranty), od109714/2024-2025:dismantling the existing old damged pump by disconnecting the cables, 15.2.1:demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in-charge.nominal concrete 1:3:6 or richer mix (i/c equivalent design mix), 4.3.1:centering and shuttering including strutting, propping etc. and removal of form work for:foundations, footings, bases for columns, 5.1.3:providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 5.22.6:steel reinforcement for r.c.c work including straightening, cutting, bending, placing i
Tender For 225 mm capacitor type propeller type ac ventilating fans-exhaust fans, 4 pole, 3 blades, 230 v, 50 hz, ac, single phase, conformity to indian standard is: 2312 (latest), isi marked, class a/b/e, minimum air delivery (m3/h) as per is: 2312 (latest) , maximum watt input (watt) as per is: 2312 (latest), power factor as per is: 2312 (latest), standard installation accessories such as frame, legs set, rubber clamps & other hardware - inclusive in the scope of supply. [ warranty period: 12 months after the date of delivery ]