Tender For supply, installation, testing and commissioning of extra material for installation of unitary ac in different departments /centers/schools, office etc. at iit kharagpur, kharagpur (phase ii) - "6.4 mm (¼"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "9.5 mm (⅜"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "12.7 mm (½"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "15.86 mm ( ⅝"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "19 mm (¾"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", interconnection electrical copper cables from indoor , outdoor & electrical control panel complete with 4 core 2.5 sqmm copper frls insulated cable(isi marked) with cable tie & clamp etc as required., supply & installation m.s epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement., supply & installation of upvc drain pipe (isi marked) with 6mm thick nitrile rubber insulation from idu - 25mm dia, 40 mm rigid upvc drain pipe (isi marked) with 6 mm thick nitrile rubber insulation complete with fittings, u traps etc. & as specified to the nearest toilet with required civil works & finishing the same., supply of r-22 gas for top up, supply of r-32 gas for top up, supply & installation of good quality wooden frame (2" x 2") thick required for window ac installation, supply & installation of 16amps plug top (isi marked), supply & installation of 100mm pvc trunking with snap on trunking (isi marked), "supplying and installing following size of perforated hot dipped galvanised iron cable tray with cover (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.", 100 mm width x 50 mm depth x 1.6 mm thickness, installation, testing & commissioning of the window ,split acs ,cassette ac supplied by department. price shall be inclusive of installtion upto 3mtr of refrigerant pipe, drain pipe and cable., window acs, split acs, cassette acs, reinstallation, lifting, shifting of existing ac units (split & window acs & cassette ac)., window acs, split acs, cassette acs, dismantling of existing ac (split ac / window ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (cassette ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, buy-back of existing unserviceable ac (split ac / window ac/cassette ac) units(all type) including all copper pipes, drain pipes mounting surfaces, etc. complete. the item shall be quoted as negative item, window acs, split acs, cassette acs, decorative pelmets of required size for idus with 16 mm thick anti termite laminated board., window ac 0.75 / 1 / 1.5 / 2 tonne gi drain tray
Tender For corrigendum : providing of facility management services - lumpsum based - thermal power plant; o&m of electrical work, cleaning of ht motor battery cell service trf cable gallery control room electric panel cable tray; consumables to be provided by service provider (inclusive..
Tender For corrigendum : procurement of vfd panel - electrical item, vfd panel with 132kw, u1000 drive in assembled condition with main switch and all internal power and control wiring and its accessories
Tender For supply of installation of medical & non medical equipments to opec hospital, raichur - automatic 2-bay surgical scrub station, storage units, single arm surgeon pendant, list board, x-ray viewing screen, smart ot touch screen control panel, hermetically sealed manual sliding door 1800x2100mm, electric wiring in side ot (frls wire), peripheral led lights (285 x 585 mm), ac casatte ac 4 ton, electrical distribution panel board / box, antistatic vinyl flooring, epoxy filler& anti-bacterial paint, walls and ceiling puff panel
Tender For corrigendum : supply of machine guarding - box 600x400x300 , machine guarding , guard for z axis , x axis rear guide way guard , cnc control post , electrical panel transformer , terminal box
Tender For supply of fuses , rheostat sliding type , capacitors , various electronic components , various lamps , plug socket piano switch , cables , bus bar with brackets , rubber mat , electrician helmet , rcc pole with accessories , safety belt , ohm meter series type shunt type portable box type , digital multi meter , a.c. voltmeter m.i. analog, portable box type housed in bakelite , milli voltmeter centre zero analog, , ammeter mc analog, portable box type housed in bakelite case , ac ammeter mi, analog, portable box type housed in bakelite case , kilo wattmeter analog , digital wattmeter , a.c. energy meter , powerfactor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer , tong tester clamp meter , megger , 3- point d.c. starter , 4- point d.c. starter , wheat stone bridge with galvanometer and battery , single phase variable auto , phase sequence indicator , growler , ac starters , oscilloscope dual trace , function generator , soldering iron , temperature controlled soldering , discrete component trainer , linear i.c. trainer , digital i.c. trainer , domestic appliances , oil testing kit , inverter with battery , voltage stabilizer , dc power supply , battery charger , current transformer , potential transformer , solar panel with battery , d.c. shunt generator with control panel , motor- generator ac to dc , d.c. compound generator with control panel including fitted rheostat, voltmeter, ammeter and breaker , dc series motor coupled with spring balance load , dc shunt motor , dc compound motor with starter , motor generatordc to ac set consisting , ac squirrel cage motor with star delta , ac phase-wound slip ring motor with starter switch , universal motor with starterswitch , synchronous motor with accessories like starter, excitation , thyristor igbt controlled d.c. motor drive with tacho-generator , thyristorigbt controlled a.c. motor drive with , single phase transformer, core type, air cooled , three phase transformer, shell type oil cooled with delta star , electrical machine trainer , diesel generator set with changeover switch over cut , used dc generators-series, shunt and compound type for overh , pillar electric drill machine motorized , motorised bench grinder , a.c. series type motor , single phase capacitor motor with , manual motor coil winding machine , ceiling fan coil winding machine , primary current injection set , stepper motor with digital controller , shaded pole motor , smart meter , ev charger , ev charger home , wiring board , metal rack , black boardwhite board , fire extinguisher co2 , fire buckets
Tender For supply of electrical lab equipment - digital multimeter , stop watch digital , connecting leads , 4mm to 4mm double point patch chord for inter-connection leng 15 inches , alligator clips , dc ammeters (0-1,2,5,... 10 amps (internal shunt) (select any on range) , wattmeter 0-75w , wattmeter 0-150w , rheostat various ranges , rheostat 300 ohms / 2 amp , rheostat 100 ohms / 5 amp , rheostat 50 ohms / 5 amp , rheostat 250 ohms / 3 amp , rheostat 10 ohms / 10 amp , resister inductor capacitor of different value (ohm.k ohm,mh,mf 10 each (set of 30) , auto transformer 1kva , lcr impedance apparatus with bakelite panel & round meters , wires , circuit kit for verification of superposition theorem , circuit kit for verification of thevenin's theorem , circuit kit for verification of norton's theorem , circuit kit for verification of maximum power transfer theorem , kelvin bridge (industrial) with dc source & galvanometer kelvin's double bridge designed 20000 6 120,000 bridge test kit compact, pottable kelvin double bridge designed , dc potentiometer kit with 12v d.c standard cell , ammeter 0-5a , ammeter 0-10a , voltmeter 0-300v , voltmeter 0-600v , single phase & three phase energy meter testing kit , rheostat various ranges , rheostat 300 ohms / 2 amp , rheostat 100 ohms / 5 amp , rheostat 50 ohms / 5 amp , rheostat 250 ohms / 3 amp , rheostat 10 ohms / 10 amp , dc shunt generator along with dc motor as prime mover with control panel , dc series generator along with dc motor as prime mover with control panel , dc shunt motor 3hp 220v 1500rpm with control panel with control panel , dc. shunt motor mechanical braking arrangement with control panel , dc series motor 3hp 220v 1500rpm with mechanical braking arrangement with control panel , three point dc motor starter 0-220v 0-10a , four point dc motor starter 0-220v 0-10a , dc voltmeter 0-230v dc , dc ammeter 0-10a , single phase transformer 230/230v,230/115v,3kva with tapping at 10%,25%,50% and 75% housed in steel box with educational type terminals provided with control panel for o.c and s.c test) consists of the following accessories. , 230/230v, 230/115v, 3kva with tapping at 10%, 25%, 50% and 75% housed in steel box with educational type terminals provided with control panel. (for o.c. and s.c. test) consists of the following accessories.a) mcb (16a, 600v) – 1 pc b) fuse 10a - 1pc c) analog ammeter (0-1a) – 1 pc d) analog ammeter (0-5a) – 1 рсе) analog voltmeter (0-50a) (0-300v) – 1 pc each f) wattmeter 1/2a, 150/300v g) wattmeter 5/10a, 75/150v h) 1-loading rheostat , 3 phase transformer 400/230v y connected 10a , single phase transformer 220v/110v, 13.62/27.25a 3kva , experimental kit for overcurrent relay idmt type relay idmt type; realy test kit (current injection unit). one number of 230v ac @ 50hz ac input with power on/off switch , air circuit breaker trainer kit patch cordes 4mm (heavy duty) 1meter lengh. high voltage test point are provided with 4mm safery sockets. the trainer is housed in metal cabinet short circuit projection with the mcb.. size of the trainer set 20"x30". , miniature circuit breaker (mocb) trainer kit minimum oil circuit breaker (mocb) trainer kit , specification: alternator , of 3ph, y connected 415v, skya, (mg -sct) , 0.8 pf, 50hz -. dc regulated power suply 0-30v, 2 amp with digital voltmeter and ammeter , miniature circuit breaker (mcb) trainer kit alphanumeric 16x2 big font lcd for better visibility isolated power supply using transformer in built variable current injection facility transparent mcb's to understand internal architecture and its working inbuilt timer, current & temperature in lcd mcbs are mounted with tempetature sensor for current temperature analysis equipped with supply indication lamp , sf6 (sulphur hexa fuoride circuit breaker trainer kit) 440volts, 3 phase 4 wire 50hz, , vacuum circuit breaker trainer kit 11kv, 800a, draw out version, motor operated spring charging with electrical and manual operation provision
Tender For establishing the primary processing, grading, branding, packing centre for branding and marketing of tur/redgram/any other crops at farmer field or village level at allur. b. village in chittapur taluka under kkrdb macro 2024-25 - total plant spouting ducting, aspiration, canopy, moisture meter, weighing scale, packing / bagging unit, bar alternator with pto working load, tractor, control panel along with electrical wiring and mechanical accessories, mobile trolly, storage bin, bucket elevators, specific gravity separator, cleaner cum grader, dump hopper with elevator