Get complete information related to latest Power Supply Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Supply Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Supply Board Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp
Tender For supply of ultrasound machine , digital tens unit , laser therapy unit , portable tens unit , deep freezer , reusable freezer ice blocks , gel pack with strap , physiotherapy suspension frame with couch and accessories or equivalent , physiotherapy treatment couch , examination couch stepper , physiotherapy equipment trolley , cryotherapy bath tub , station separator for three physiotherapy stations , three hundred and sixty degree shoulder wheel , yoga mat , foam roller , ankle and heel exerciser , cushions for physiotherapy positioning and support , resistance band set , half balance ball trainer , balance board , repair and servicing of existing ultrasound therapy machine , repair and servicing of existing shortwave diathermy machine , station name boads , main name board , equipment description boards , physiotherapy exercises boads , electric works * /bid number : gem/2026/b/7703772 + /dated: 30-06-2026 ' ' / bid document 1 / 27
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box