Get complete information related to latest Propeller Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Propeller Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Propeller Scrap Tenders.
Tender For a/mtc. for electrical installation (e.i.), including ups lights fixtures, fan and exhaust fans in hsvp office building sector-12 faridabad. - a/mtc. for electrical installation (e.i.), including ups lights fixtures, fan and exhaust fans in hsvp office building sector-12 faridabad. a/cost rs.4.24 lacs e/money rs.8480.00 time limit : 12 months
Tender For corrigendum : special repair replacement of earthing pits and allied services at north camp provn of exhaust fan in smqs at south camp and happy home and provn of certain em works services at phaphamau under ge af bamrauli
Tender For supply of wiring for light point fan point exhaust fan point call bell point group c as per atc attached , item no.2 , item no.3 , item no.4 , item no.5 , item no.6 , item no.7 , item no.8 , item no.9 , item no.10 , item no.11 , item no.12 , item no.13
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply of engine block and acessories for 4018c tata motors vehicle : : - long block 6bt bs3 front sump bs1 3 , air compressor bs1 2 3 , assy turbocharger bs1 3 , assy radiator bs1 3 , rad bottom hose p n 278650115859 , pipe assy crimped , hose engine to radiator inlet bs4 , rubber hose p n 206950105823 , assy vane pump bs1 2 3 4 , pulley fan ratio 1 2 1 bs1 2 3 4 , gasket exhaust manifold bs1 3 4 , screw head flange head cap 278614999964 , tensioner belt bs1 2 3 4 , belt v ribbed bs1 2 3 4 , engine mount pad front bs1 2 3 4 6 , engine mounting rear bs1 2 3 4 , hose clamp tb72 sae j1508 , hose intercooler outlet p n 278614605818 , pipe cac out p n 278614606987 , pipe cac in p n 27861460986
Tender For supply of electric ceiling fan (v4) isi marked to is 374 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 (q2) , air circulator type electric fan and regulator (v2) conforming to is 2997 (q2)