Tender For supply of commercial proposal for unified communication system with inbuilt call recording (i) aegis xntel unified communication system: 01 no. *inbuilt call recording facility *advance searching tool *phonebook & directory facility* *call transferring *voice conference calling for virtual meetings * mobile extension / softphone* * customize call pop-up for incoming calls (ii) gsm voice terminal 4g/volte (gsm fct): 02 nos *sim based communication *crystal clear voice *compatible with all sim operators *quick and trouble free installation (iii) 8 port gigabyte switch - 01 no. (iv) executive phone (xn101): 02 nos. * support 2 lines call information *support 5 programmable keys for redial, dnd, phonebook, speed dial, call history, main menu and many more. *support multiple languages : english, french, russian, ect. (iv) beetal 2 line lcd telephone: 02 nos [ warranty period: 12 months after the date of delivery ] ]
Tender For corrigendum : routine monitoring / preventive maintenance / breakdown / emergency /regular servicing of pneumatic cylinders, solenoid valves, limit switches & pressures switches pertainsto units-5,6 &7 mill reject handling system(mrhs).operation and maintenance of dense phase mill reject handling systemof unit-8.the work involves-a)operation and maintenance of dpmrhs plc systemb)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves,limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systemspertains to unit-5 to 8.the work involves-a)operation and maintenance of dpmrhs plc system.b)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves, limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systems pertains to unit-5 to 8.the work involves-a)cleaning/servicing of transmitters & reflector units and blower filters of spm analyzers, pertains to units-5 to 8.b)carrying out maintenance works under the supervision of i&c engineerregular monitoring/checking healthiness of unit-7&8 coal bunker level monitoring systems.routine maintenance of bunker level monitoring systems.the work involves- a) cleaning/checking of 3d level sensors.b) cleaning/checking healthiness of local control panel at bunker floor.c) ensuring healthiness of signals to control room pc,dcs&chp control room digital indicators.regular monitoring/maintenance of hfo tanks level measurement systems.the work involves-a)cleaning/checking healthiness of radarleveltransmitters installed at hfo tanksb)cleaning/checking healthiness of local digital indicators installed at foph.c)cleaning/checking healthiness of plc unit installed at unit control room-7.the nature of work is round the clock maintenance.the cleaning/servicing and maintenance works of all the above mentioned systems shall be carried out during units aoh period.the required t&p and ppe for carrying out maintenance works shall be arranged by the contractor/agency itself.
Tender For corrigendum : supply, installation, and commissioning of non-contact type radarleveltransmitters for acw tanks, bcw tanks, and cst in units 1 to 3 at wtps.
Tender For submission of a rate schedule for machinery and equipment to prepare an estimate for installing rainwater harvesting systems in stormwater lines and low lying areas along main and internal roads within the municipal corporation limits. - item name, providing and constructing recharge pit of 2.0m deep and 1.0m dia of precast rcc rings with 6.5 dia. x 25m deep bore well at the floor of recharge pit including providing and supplying one complete ai-enabled single integrated modular smart groundwater recharge unit with recharge-volume measurement, real-time clog monitoring, recharge-water quality monitoring, soil quality / site suitability assessment, iot communication, ai dashboard and gis monitoring platform, suitable for urban rainwater and storm water groundwater recharge applications. the supplied unit shall be a single integrated smart recharge unit and shall not be a combination of disconnected or separately assembled devices. all field-level hardware, sensors, filtration arrangement, sedimentation section, recharge-volume measurement system, real-time clog monitoring system, recharge-water quality monitoring system, iot controller, communication module, qr/gis asset identification and data communication components shall be integrated within the supplied smart recharge unit and shall operate as one complete system. the ai dashboard, gis monitoring platform, cloud hosting, sim/data communication and software support shall be digitally integrated with the supplied unit for live monitoring, alerts, analytics and reporting. internal components shall not be treated as separate payable items. the main body / modular assembly of the unit shall be made primarily from hdpe/frp / upvc or equivalent corrosion free material and shall be suitable for long-term contact with rainwater / storm water, groundwater recharge applications and repeated cleaning. the unit shall be corrosion-resistant, water-resistant, durable and easy to maintain. the unit shall be modular, removable, reusable and serviceable. the design of the unit shall enable cleaning, sediment removal, filter inspection, filter-media replacement, sensor inspection and refitting without damaging the surrounding civil structure, chamber or recharge arrangement. the unit shall have a minimum external diameter of 750 mm and minimum overall height of 2000 mm with frp cover of suitable size having 40 mt capacity. the unit shall have sufficient internal space for filtration arrangement, sediment holding, recharge-volume measurement, real-time clog monitoring, water-quality monitoring, iot components, sensor housing, cleaning access and maintenance. the unit shall include multistage filtration, debris arrest arrangement, first-flush / bypass provision, sedimentation and silt-management section, recharge-volume measurement system, recharge-rate monitoring, real-time clog monitoring, recharge-water quality monitoring after filtration and before recharge, soil quality / site suitability assessment module, iot-based data communication, qr, gis asset identification, ai-enabled web dashboard, gis monitoring platform. the unit shall be capable of measuring, recording and reporting actual recharge volume, recharge-rate trend, sedimentation status, clogging condition, recharge-water quality parameters, soil / site suitability parameters, unit health, sensor health, battery status, communication status and maintenance status on a web-based dashboard. the item shall be treated as one complete integrated smart unit. internal components such as hdpe/ frp modular body, filtration arrangement, sedimentation section, measurement systems, sensors, iot controller, communication module, ai dashboard, gis platform, cloud hosting and sim/data support shall not be measured or paid separately. the unit shall have authentication from any govt. institute like c.o.e.p./cw&prs/gsda etc. the unit shall be supplied with five years warranty against manufacturing defects, material defects and functional failur
Tender For bench top pressure gauge calibrator with accessories- pressure calibration system, maximum no. of pressure module simultaneously, working medium, mode, sensor module range 1, accuracy of sensor module range 1, sensor module range 2, accuracy of sensor module range 2, precision, uncertainty of sensor module range 1, uncertainty of sensor module range 2, measurement modules, control mode, control precision, lowest controllable pressure limit, pressure indication & display system, over pressure protection, leak test & switch test, jog wheel, system mode, valve driver, vacuum pump, contamination prevention system, pressure display units, dc voltage range, dcv resolution, dcv uncertainty, dc current range, dci resolution, dci uncertainty, loop compliance voltage, hart mode, automatic hart detection, hart selectable resistor, write protection, hart commands, remote communication interface hardware, ac power supply, operating temperature range, relative humidity, ingress protection, plumbing lines, fittings and adaptors, warranty, calibration certificatte, test port max. pressure limit, reference port max. pressure limit, vent port max. pressure limit, test port, supply port max pressure limit, liquid or particle filter