Tender For corrigendum : supply, installation, and commissioning of non-contact type radarleveltransmitters for acw tanks, bcw tanks, and cst in units 1 to 3 at wtps.
Tender For corrigendum : routine monitoring / preventive maintenance / breakdown / emergency /regular servicing of pneumatic cylinders, solenoid valves, limit switches & pressures switches pertainsto units-5,6 &7 mill reject handling system(mrhs).operation and maintenance of dense phase mill reject handling systemof unit-8.the work involves-a)operation and maintenance of dpmrhs plc systemb)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves,limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systemspertains to unit-5 to 8.the work involves-a)operation and maintenance of dpmrhs plc system.b)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves, limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systems pertains to unit-5 to 8.the work involves-a)cleaning/servicing of transmitters & reflector units and blower filters of spm analyzers, pertains to units-5 to 8.b)carrying out maintenance works under the supervision of i&c engineerregular monitoring/checking healthiness of unit-7&8 coal bunker level monitoring systems.routine maintenance of bunker level monitoring systems.the work involves- a) cleaning/checking of 3d level sensors.b) cleaning/checking healthiness of local control panel at bunker floor.c) ensuring healthiness of signals to control room pc,dcs&chp control room digital indicators.regular monitoring/maintenance of hfo tanks level measurement systems.the work involves-a)cleaning/checking healthiness of radarleveltransmitters installed at hfo tanksb)cleaning/checking healthiness of local digital indicators installed at foph.c)cleaning/checking healthiness of plc unit installed at unit control room-7.the nature of work is round the clock maintenance.the cleaning/servicing and maintenance works of all the above mentioned systems shall be carried out during units aoh period.the required t&p and ppe for carrying out maintenance works shall be arranged by the contractor/agency itself.
Tender For tender for supply of transmitter for boiler area - differential pressure transmitter range0 to500mmwc model no 305v differential pressure transmitter range0 to500mmwc model no 3051cd2a22a1ab4m5q4d4 12 inch npt f fitting with 5 way manifold make m s emerson rosemount 1cd2a22a1ab4m5q4d4 12 inch npt f fitting with 5 way manifold make m s emerson rosemount , differential pressuretransmitter tagno hbk20cp00 2 range 0 to 850mmwc model no 3051cd2a22a1ab4m5q 4d4 12 inch npt f fitting with 5 way manifold make emerson rosemount , differential pressure transmitter range 0 to 2000 mm wc model no 3051cd1a22a1ab4m5q4d4 fitting with 5 way manifold connection 12 inch npt f make emerson rosemount , input 24vdc output 420 ma accuracy 02 display 46 digit with external zero and span push button hart protocol compatible process connection 12 14 npt flange adapter s cable gland 12 npt damping time 0 16 sec enclosure aluminum ip67 max working ambient temp 80deg c range 0 15000 mm wc fitting with 5 way manifold make m s emerson rosemount , guided waive radarleveltransmitter range 0 to 780 mm probe length 930 mm flange 1 inch top mounting make m s make emerson rosemount guided waive radarleveltransmitter range 0 to 780 mm model no5301ha1s1v4am00093abnam1c1q4 probe length 930 mm flange b165 2 300 s4 f316 f316lbs55 7000001 678 pm ab process connection type 2 inch top mounting make m s make emerson rosemount , pressure transmitter tag no laa10cp012 range 0 to 16kg cm2 model 3051tg3a2b21ab4k5d4m5q4 2 way manifold emerson rosemount , pressure transmitter tag no la10cp024 range 0 to 300kg cm2 model 3051tg5a2b21ab4k5d4m5q4 2way manifold emerson rosemount , differential pressure transmitter tag no hfe60cp00 1 range 0to10kg cm2 model no 3051cd4a22a1ab4m5 q4d4 emerson rosemount
Tender For digital controller size: 96 x 96 ip 4-20ma supply 100-250 vac, digital display with programming , programmable radarleveltransmitter for cement silo, range -50meter i/p: 220v ac, o/p: 4-20 ma , ma-ma convertor, i/p: (0-20/4-20 ma) supply: 100-250 vac o/p: dual (4-20 ma)