Web Analytics Made Easy - StatCounter

Reheater Tenders

Get complete information related to latest Reheater Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reheater Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reheater Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45715219 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For work of h.p. parts repairs in second pass of boiler including ltsh, economizer, platen sh, front & rear reheater during aoh/coh of unit-5 at 2 x 500 mw, bhusawal tps.

Central Government And Public Sector

CTN :45609040 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : tender for supply of spares for reheater spray control valve - split packing ring 1.5 v/v , gasket-liner/seat ring 1.5 , gasket-body for dresser 88-18262 , radial dynamic gasket 1.5 , liner & seat ring-dresser 88-18262 1.5 , seal retainer for 1.5 rh spray ctrl.v/v , plug & stem m/c-dresser 88-18262 1.5

CTN :45738463 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For reheater front bottom bend 02 , 120 degree bend for reheater front of circuit 2 , reheater straight tube od 54.00 x 4.00 - sa213t22 , reheater front bottom bend 05

CTN :45716595 Due date: 13 Jul, 202613 Jul, 2026 4.50 Lacs
Tender For supply of fabrication c c - damaged washing pipeline nipple flange band on pan no 6 3 , replace damaged washing pipeline nipple flange band on pan no 6 4 , install valve in steam line at pan no 2 550 mm 1 , install valve in steam line at pan no 2 550 mm 2 , install valve in steam line at pan no 2 550 mm 3 , install valve in steam line at pan no 2 550 mm 4 , replace nipple and band of a heavy tank 2 , replace nipple and band of a heavy tank 3 , replace nipple and band of a heavy tank 4 , remove clean and reinstall 4inch size syrup line on pan , cut and remove syrup header and fabricate and install new header , replacing the 6inch size glycol washing line fitted on pan no 1 , replacing nipples of different lines of pan no 6 1 , replacing nipples of different lines of pan no 6 2 , replacing nipples of different lines of pan no 6 3 , replacing nipples of different lines of pan no 6 4 , replacing 10inch size nipples of cut off line of pan no 6 1 , replacing 10inch size nipples of cut off line of pan no 6 2 , replacing 10inch size nipples of cut off line of pan no 6 3 , replacing 10inch size nipples of cut off line of pan no 6 4 , replacing corroded hot water pipeline nipples flanges valves in pan no 4 1 , replacing corroded hot water pipeline nipples flanges valves in pan no 4 2 , replacing corroded hot water pipeline nipples flanges valves in pan no 4 3 , replacing corroded hot water pipeline nipples flanges valves in pan no 4 4 , fabricating m s bed for syrup pump and motor fitting and alignment followed by satisfactory trial , dismantling weak condensate bottle of old set , replacing weak pipeline flange valve and band of old set vertical juice heater 1 , replacing weak pipeline flange valve and band of old set vertical juice heater 2 , replacing weak pipeline flange valve and band of old set vertical juice heater 3 , replacing weak pipeline flange valve and band of old set vertical juice heater 4 , replacing weak pipeline flange valve and band of old set vertical juice heater 5 , replacing weak pipeline of old quad set no 4 1 , replacing weak pipeline of old quad set no 4 2 , replacing weak pipeline of old quad set no 4 3 , replacing weak pipeline of old quad set no 4 4 , replacing weak pipeline of old quad set no 4 5 , dismantling damaged mesh of section pipe located at injection no 2 and 3 and making a new one from given m s plate and fitting it , cutting and discarding old damaged reducer plate of section pipe located at injection no 2 and 3 and remaking the same , fitting water line from overhead to service tank 1 , fitting water line from overhead to service tank 2 , details of work of canti machine no 6 and 7 1 , details of work of canti machine no 6 and 7 2 , details of work of canti machine no 6 and 7 3 , details of work with new pipes from s sugarbin 1 , details of work with new pipes from s sugarbin 2 , details of work with new pipes from s sugarbin 3 , details of work for kcp no 1 and 2 and canty machine no 6 and 7 1 , details of work for kcp no 1 and 2 and canty machine no 6 and 7 2 , details of work for kcp no 1 and 2 and canty machine no 6 and 7 3 , work on hot water line of brown sugar magma 1 , work on hot water line of brown sugar magma 2 , work on hot water line of brown sugar magma 3 , work on hot water line of brown sugar magma 4 , cutting and removing damaged monitor casing and ribs , cutting and removing damaged center shaft and arms inside kcp machines no 1 and 2 bending and fitting new parts with 8 to 10 mm plate , dismantling damaged upper cover part of canty machine no 6 and 7 scrapping fabricating and fitting new cover with 12 mm plate and making all related connections , dismantling damaged part of molasses weighing scale receiving tank and fabricating and fitting new part by bending 8 mm thick //bid details 2 / 117 / / 1 1 /item category plate and depositing scrap in scrap yard , dismantling damaged plate of sugar discharge chute from sugar elevator to sugar grader and fabricating and fitting new pl

corporations/Associations/Others

CTN :45706460 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For tender for supply of reheater block valve with actuator , plug m/c 2 inch sh , plug pin 2 inch 41k , sh spray c/v body gasket 2 inch , sh spray c/v split packing ring (919) , sh spray c/v split packing ring (933) , plug m/c 2 inch rh , rh spray c/v seat ring m/c 2 inch , gasket body 2 inch 78200 2500 , rh spray c/v flexible graphite packing , plug stem m/c 0.75 inch-16unf-2a , body gasket 2 inch 41k 2500 , plug stem(shouldered) 1/2 inch , sh spray c/v seat ring m/c2 inch

State Government

CTN :45701261 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For work of repair/servicing of cci make superheater & reheater spray control valves & prds spray control valves in bhel boiler of unit no.3 during coh at cstps, chandrapur.

State Government

CTN :45699883 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For work of h.p. parts repairs in second pass of boiler including ltsh, economizer, platen sh, front & rear reheater during aoh/coh of unit-5 at 2 x 500 mw, bhusawal tps.

corporations/Associations/Others

CTN :45666729 Due date: 08 Jul, 202608 Jul, 2026 34.11 Lacs
Tender For tender for supply of tubular protector for spacer tube , size l-1000mm , id-55 mm , tubular protector for rear w.w. screen tube , size l-1500mm , id-55mm , tubular protector for final s.h. tube , size l-1000mm , id-55mm , tubular protector for tertiary super heater & reheater size 1500x58.0x4.0 mm , tubular protector for tertiary s.h. tube , size l-1000mm , id-57mm , u clamp of size id-57 mm , u clamp of size id-63mm , tubular protector for economizer & primary s.h. vertical tube , size l-1000mm , id-52mm , tubular protector for economizer & primary s.h. vertical tube , size l-1500mm , u clamp of size id-53mm , tubular protector for pri. s.h. tube , size l-1500mm , id-45mm , u clamp for ash protector of primary sh horizontal size id-45 mm , tubular protector for sec. & ter. rh coil , size l-1500mm , id-64mm , u clamp of size id-65 mm , width 40mm , th.-4.0mm , 90 degree bend tubular shield for primary super heater horizontal size id-45.5 mm , reverse 90 deg bend ash protector for primary sh horizontal size id-45.5 mm , semi circular protector for spacer tube 60 deg bend size-1500x65x4 mm

State Government

CTN :45616105 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For work of repair/servicing of cci make superheater & reheater spray control valves & prds spray control valves in bhel boiler of unit no.3 during coh at cstps, chandrapur.

State Government

CTN :45585322 Due date: 21 Jun, 202621 Jun, 2026 NA
Tender For work of h.p. parts repairs in second pass of boiler including ltsh, economizer, platen sh, front & rear reheater during aoh/coh of unit-5 at 2 x 500 mw, bhusawal tps.
 Loading, Please wait...

Connect us via What's Up