Web Analytics Made Easy - StatCounter

Relay Panel Tenders

Get complete information related to latest Relay Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44927757 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For corrigendum : works of preventive maintenance, shutdown & emergency maintenance of grp,ht/lt switchgear,400/220kv/gis switchyard /coal yard c/r relay panel compartment cleaning, tb tightness, electrical testing kit lifting/shifting work etc.

State Government

CTN :45314830 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For supply and fixing of numerical undervoltage and ndr protection relay suitable for 33 kv 2x5 mvar capacitor bank bay at 132 kv s/s bansi

Central Government/Public Sector

CTN :45010381 Due date: 01 Jun, 202601 Jun, 2026 5.06 Crore
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - ehv substation; control and relay panel; as per gcc/scc/ts

State Government

CTN :43902267 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For corrigendum : 33kv indoor twin feeder control and relay panels

State Government

CTN :45082846 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For corrigendum : 33kv 220v dc1600a feeder vcbs with current transformers of ratio 400-200-100/1-1a (without control and relay panels)

CTN :45271786 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of material required for repair/maintenance /restoration of 33kv lines and 33/11kv receiving stations in respect of std-iv kalakote, for the year 2026-27 or till next contract. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf

CTN :45277957 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of materials for 33kv lines and 33 by 11kv recieving stationsfor the year 2026-27. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf conductor, b&s 4 u-bolts type, 33 kv tension fittings for acsr panther conductor, b&s

CTN :45302209 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For work of complete renovation, revamping and online removal of adhered contaminates using nccc (non-cyclic cryogenic cardice) technique from the live marshalling box (mb) installed in 220kv & 33kv switchyard and work of online removal of adhered contaminates using nccc (non-cyclic cryogenic cardice) technique from control & relay panels installed in the control rooms of 400/220/33kv khaparkheda s/s & 400/220kv koradi-1 s/s under ehv (o&m) circle nagpur.

Central Government/Public Sector

CTN :45303150 Due date: 02 Jun, 202602 Jun, 2026 24.38 Lacs
Tender For supply of auxiliary transformer prim 110 220v, part no. mlpat209 , delay timer electronic 0 - 30 s, part no. mlpbch210 , protection relay for motor, part no. mlprm100 , brass cable gland, part no. mlpbcg107 , ammeter , analogue, 96 sq mm, part no. mlpaa111 , voltmeter , analogue ,72 sq mm, part no. mlpbr113 , lamp red 110 v ac, part no. mlpboskr120 , lamp yellow 110 v ac, part no. mlpbosky121 , lamp green 110 v ac, part no. mlpboskg122 , push button actuator with 1 no 1nc, part no. mlpbovsne127 , ct,100 5 double ratio, part no. mlprcct159 , ct,75 5 double ratio, part no. mlprcct160 , vacuum bottle 1250 amp, part no. mluvb207 , master trip relay, part no. mlumt212 , pneumatic type on delay timer ,0-30 sec, part no. mlptimer144 , earth leakage relay, part no. mlpelm148 , isolator , off load, part no. mlpkhti150 , bridge rectifier 10 amp 110 v ac to dc, part no. mlpbrd157 , yellow push button, part no. mlpbov171 , red push button, part no. mlpbov172 , green push button, part no. mlpbov173 , numerical overcurrent relay, part no. mlpnor181 , vcum cntctr asly,400a,6.6kv,85-230vac dc, part no. mlpasras136 , pt fuse, f 6.6kv 7.2kv,3.15a, part no. mlptfs102 , under and over voltage relay, part no. mluov218 ) /bid number : gem/2026/b/7564535 * /dated: 23-05-2026 & & / bid document 1 / 27

State Government

CTN :43810552 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For corrigendum : design, supply, installation, testing, commissioning including dismantling, replacement of control and relay panel for 66kv line feeder & transformer feeder at ukai hps. (emd-hps et-6186)
 Loading, Please wait...

Connect us via What's Up