Get complete information related to latest Relay Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Set Tenders.
Tender For supply of pressure sensing device having rated impulse withstand voltage (ump) - 4000v & rated operational current ac - 15:230v-2a, dc-13:24v-2a, 110v-0.25a, 24v ac-dc-0.1a along withfixing bracket, as per eaton pt.no. mcs 11-g + s3-mcs,conforming to iec60947-5-1., make : eaton or equivalent, having same fitment and functional compatibility. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relayset unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For supply of "proximity scanner of sensing distance 10 cms to 90 cms adjustable. operating voltage 15 v to 260 v ac with 1 no relay out put contacts rated for 1a at 250 v ac similar to datalogic make ]
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relaysetting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relaysetting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relaysetting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relaysetting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relaysetting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relaysetting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For supply of proximity sensor ,model iqhbd_ps_1v1, 50 mm sensing range, flush mountable normally open/closed output function, e-voice connector operating voltage: 10 to 30 v dc [ warranty period: 24 months after the date of delivery ] ]
Tender For instrument spares for refinery - 3 way manifold, pressure-0 to 120 kg/cm2, with all mounting studs and accessories., air filter regulator, pressure 7 kg/cm2 make- precision, analog input card 8 channel for siemens make dcs part no. 331-1kf01-0ab0 make- siemens, analog ouput card 8 channel for siemens make dcs part no. 332-5hf00-0ab0 make- siemens, bagging machine controller for automatic bagging machine, make power build, model no c750 make- mettler toledo, chute lever sensor high temp. make- yu technologies pvt. ltd,, differential pressure switch, range 0.2 to 6 bar, differential - .25 to 1.2bar, sensing element- copper alloy, elec. ranting- ac-1 : 10 a, 230v ac, make- wika, digital input card 32 channel for dcs part no. 321-1bl00-0aa0 make- siemens, digital output card 32 channel for dcs part no. 322.1bl00-0aa0 make- siemens, discharge valve for pan discharge, input/output connection , double siphon pressure 120 kg/cm2, input/output connection : : threaded, flow meter totalizer, model no. 1008s, input-4 to 20 ma make massibus, flow meter for imbibitions water flow, range -100 tph, line size 4 make- krhne marshall, chute level indicator cum controller, no of sensor 6, output-4 to 20 ma, input supply-230 vol ac make- yu technologies pvt. ltd,, k type thermocouple sensor length -400mm, sensor thickness-6mm, duel output connection, input connection-1/2 npt (m) make- temson, load cell for automatic bagging machine, capacity-110 kg, positioner for control valve i/p 4-20ma, o/p- 4-20ma, make- ytc, pressure gauge range 0 to 160 kg/cm2, dial size 8 inch, input connection (bottom) npt(m) making black & white back ground make- baumer, pressure gauge- range- 0 to 20 kg/cm2, dial size: 150 mm, input connection : (bottom) npt (m), making : black & white back ground, with glycerin filled type make- baumer, pressure gauge- range- 0 to 4 kg/cm2, dial size: 150 mm, input connection : (bottom) npt (m), making : black & white back ground, make- baumer, pressure gauge- range- 0 to 25 kg/cm2, dial size: 150 mm, input connection : (bottom) npt (m), making : black & white back ground, with glycerin filled type make- baumer, pressure gauge- range- 0 to 10 kg/cm2, dial size: 150 mm, input connection : (bottom) npt (m), making : black & white back ground, make- baumer, smart type pressure transmitter , input 0 to 120 kg/cm2, input connection npt (m), hart enabled, with all mounting accessories. make- yokogawa/honeywell, pu tee, 8 mm x make- janatics, pu connector size dia, 8x make- janatics, pu connector both size flange size dia, 8x x 8x make- janatics, pu tube cap. dia 8 x , pressure-30 bar one roll-100 mtrs. make- janatics, rtd pt 100, sensor length 400mm, sensor thickness-6mm, duel output connection, input connection- npt 9m) make temson, sack grip belt for automatic bagging machine, seal kit for automatic bagging machine, model no. dnu 50, for bag clamp cylinder make- festo, seal kit for automatic bagging machine, model no. dnu 40, for course/fine cylinder make- festo, seal kit for automatic bagging machine, model no. dnu 40, for discharge cylinder make- festo, shuttle assembly for automatic bagging machine. make-festo, siemens s7 400 dcs backup batteries part no. 6es7971-0ba00 dc voltage- 3.6 vol make- siemens, single isolator input 0 to 1 amp. ac, output 4 to20 ma,(dual), input supply- 230 vol ac make- massibus, single isolator input 0 to 10 vol dc, output 4 to 20 ma,(dual), input supply- 230 vol ac make- massibus, single isolator input 4 to 20 ma, output 0 to 10 vol dc, (dual), input supply- 230 vol ac make- massibus, smps 24 vol dc source, input voltage: 110 vol dc/ 230 vol ac, output: 24 vol dc make- papper + fuchs, temperature gauge, spec- range 0 to 200 degree c, dial size 150mm, input connection: (bottonm) npt (m), making : black & white back ground, sensor thickness 6mm, capillary type, capillary length 1.5 mtr. make- baumer, temperature gauge, specification range -0 to 150 degree c, dial size: 150 mm, input conne
Tender For corrigendum : tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for pfc and tri