Get complete information related to latest Relay Valve Spare Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Valve Spare Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Valve Spare Tenders.
Tender For bid to ras corrigendum : supply of catheter micro neuro flow guided with proximal braiding , coil detachable fibered such as interlock 18 from boston scientific , catheter guiding, neuro with variable pitch nitinol coil for better proximal support distal flexibility minimal ovalization largest id , embolic agent liquid evoh based for use in intracranial vascular malformation , catheter micro neuro, dmso compatible with detachable tip, for use in the intracranial circulation such as apollo from medtronic sonic from balt , catheter guiding distal access large diameter for neurointervention braided , wire micro neuro, hydrophilic coated 0 point 08 inch dia and 200 cm long , tips introducer set such as rtps haskal from cook medical , catheter micro peripheral distal od , wire micro neuro nitinol based stainless steel distal tip core , flow diversion embolisation device for intracranial aneurysm , ethiodized oil based contrast agent for radioopacity such as lipiodol from guerbet , catheter micro neuro with distal id , single y rotating hemostatic valve adaptor such as passage hva from merit medical , embolic agent liquid nbca , intracranial reperfusion catheter for thrombus aspiration in acute stoke with large , intracranial reperfusion catheter for thrombus aspiration in acute stoke , catheter guiding distal access, large diameter for neurointervention , headway due neuromicrocatheter , double tip braided detachable tip microcatheter compatible with dmso , delivery guiding catheter , microplex complex coils 10 coils , axium prime complex 3d detachable neuromicro coil , pre shaped tip low profile shaft neuromicrocatheter with , vertible hydrophillic angiography glide catheter , disposable automatic and semi automatic core biopsy gun , high torque command wire shapable nitinol tip 3 cm distal radioopaque tip length 300 cm , catheter micro for neurointervention with distal od , ethyl vinyl alcohal polymer with dmso opacified with micronized tantalum for malformations like onyx 18 , 2 point7 1 point 5f tip flow directed dmso compatible neuro microcatheter catheter micro neuroflow guided with proxinmal braiding, id 0.027 inch, od 2.8 f distal and 2.8 f proximal, compatible with 021 guidewire like rebar 27 from ev3, coil detachable fibered such as interlock 18 from boston scientific, catheter guiding, neuro with variable pitch nitinol coil for better proximal support, distal flexibility & minimal overlization largest id of 0.072 available in 6 f such as navien from medtronic, embolic agent, liquid, evoh for use in intracranial vascular malformation such as squid 18 from balt, catheter micro neuro, dmso compatible with detachable tip, for use in the intracranial circulation such as apollo from medtronic/sonic from balt, catheter distal guiding access large diameter for neuro intervention bradided 0.088 id 90 cm length such as neuron max from penumbra/ballast from balt, wire micro neuro hydrophilic coated 0.008'' dia and 200 cm long such as chikai from asahi hybrid from balt/mirage from medtronic, tips introducer set such as rtps/haskal from cook medical, catheter micro, peripheral, distal od-2.7 f, proximal od -2.9 f and distal id-0.02'' dia and 130 cm long with microwave such as progreat from terumo, wire micro neuro, nitinol based, stainless steel diatal tip core 0.012 od with docking wire such as traxcess 14/ equivalent from microven, flow diversion embolisation device for intracranial aneurysm (80% resheathable) such as pipeline from medtronic/derivo //bid details 2 / 31
Tender For corrigendum : instruments for vats (video assisted thoracic surgery) - instruments for vats (video assisted thoracic surgery) (5 nos) - telescope 30 , enlarged view, diameter 10 mm, length 31 cm, autoclavable. fiber optic light transmission incorporated, telescope30 , enlarged view, diameter 5mm, length29cm, autoclavable, telescope, diameter 10 mm, length 32 cm, autoclavable, variable direction of view from 0 - 90 ,adjustment knob for selecting the desired direction of view, fibre optic light transmission incorporated, trocar,size11mm, autoclavable consisting of: trocar, with blunt tip, trocar cannula, flexible, without valve, length 8.5 cm, trocar, size6mm, autoclavable consisting of: trocar, with blunt tip, trocar cannula, flexible, without valve, length 8.5 cm, trocar, size11mm consisting of:trocar with blunt tip, length6cm, size11mm, trocar, size11mm consisting of:trocar with blunt tip, length6cm, size13mm, trocar, size11mm consisting of:trocar with blunt tip, length6cm, size6mm, trocar with blunt tip, with 45 luer-lock connection for insufflations, 11mm, working length 8.5cm, parenchymal forceps, atraumatic, straight jaws, single action jaws, size 5mm, length 28 cm, consisting of: mouret metal handle with haemostat style ratchet, axial with 4 locking positions for outer tube with working insert, lung forceps, dismantling, atraumatic, curved jaws, fenestrated single-action jaws in 5mm 28 cm, consisting of: mouret metal handle with haemostat style ratchet, axial with 4 locking positions for outer tube with working insert, parenchymal forceps, atraumatic, double curved jaws, size5mm, length28cm, consisting of: metal handle without ratchet with 4 locking positions, outer tube with working insert, lung forceps, atraumatic, fenestrated, single curved jaws ,size5mm, length28cm, consisting of: metal handle without ratchet with 4 locking positions, outer tube with working insert, lung nodule forceps, atraumatic, fenestrated, curved jaws, single action jaws, size 5 mm, length28cm, consisting of: metal handle without ratchet with 4 locking positions, outer tube with working insert, grasping forceps, cobra-jaws, 1x2teeth, straight jaws, single action jaws, size5mm, length 28cm, consisting of: metal handle with 4 locking positions outer tube with working insert, clickline parenchymal forceps, atraumatic, dismantling, without connector pin for unipolar coagulation, single action jaws, single curved jaws, size 5 mm, length 28 cm, consisting of: metal handle along with outer sheath with forceps insert, for use with linear staplers., grasping forceps, rotating, with connectorpinforunipolarcoagulation,size5mm,length30 cm, atraumatic, fenestrated, curved, single action jaws, consisting of plastic handle, without ratchet, with larger contact area, outer tube insulated & insert, kelly dissecting and grasping forceps dismantling, curved jaws, double action jaws, size 5mm, length 28 cm, consisting of: metal y-handle, with absorber1 geometry, axial, with 4 locking positions, outer tube with forceps insert, scissors insulated, straight jaws, curved scissor-blades, double action jaws, size5mm ,length 28cm, with connector pin for unipolar coagulation, consisting of: insulated metal handle with 4 locking positions, insulated outer tube with working insert, scissors, insulated, distally angled outer sheath, curved scissor-blades, scissor blades open horizontally to angulation, double action jaws, size5mm, length28cm, with connector pin for unipolar coagulation, consisting of: insulated metal handle with 4 locking positions, insulated outer tube with working insert, scissors, insulated, distally angled outer sheath, straight scissor-blades, scissor blades open parallelly to angulation, single action jaws, size 5 mm, length 28 cm, with connector pin for unipolar coagulation, consisting of: insulated metal y-handle with 4 locking positions, insulated outer tube with working insert, biopsy forceps, insulated, distally angled outer sheath, single acti
Tender For supply of pressure extension tubes ct coiled y tube with a single check valve designed for use with dual head ct injectors 2. 1 mpa , 190 ml syringe with quick fill tube , synthetic biodegradable trilayered dermal implant matrix with 2mm thickness size 5 x 5cm , synthetic biodegradable trilayered dermal implant matrix with 2mm thickness size 10 x 10cm , disposable mouthpiece , t u r p set , split thickness skin graft blade , heparinized syringe , single layers 5 clamp head neck and shoulder mask with nose hole , single layers 6 clamp pelvis mask medium , single layers 3 clamp brain orfit , single layers 2 clamp thorax orfit , single layers 4 clamp thorax orfit , single layers 4 clamp abdomen orfit , adhisive dressing bandage antiseptic , i v infusion set with auto air stop and priming filter with fixed leur lock , biopsy punch 1mm , biopsy punch 2mm , biopsy punch 3mm , biopsy punch 4mm , biopsy punch 5mm , ethylene oxide cartridges 170gm , arterial line catheter 3 fr , arterial line catheter 5 fr with dilator ) /bid number: gem/2025/b/6910997 * /dated: 24-11-2025 & & / bid document1 / 21
Tender For e-bid for rate contract cum supply and empanelment of surgical items - "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 20g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 22g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon/ ptfe i.v. cannula without port. size 24g suitable for paediatric & neonatal use should be packed in transparent, single blister pack. as per is 10555 standard", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sheet kink resistant flexible tubing not less than 90 cm in length should have non-return valve top drainage outlet graduated bag moulded handle for easy handling, vaccum suction set, 2.5 meter length, suction handle with suction tube sterile, pyrogenic free, latex free, single use, vascular catheter 5fr/16g, double lumen length 50cm.usfda/four digit notified ce approved. should have two guide wire 45 cm & 80cm or more(logline iv.) peel-away sheath glide thru 5fr *10 cm, guide wire nitinol 80 cm, guide wire nitinol 45 cm, introducer needle 21 g *7 cm,syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 50 cm, dressing statloock stabilization device , vascular catheter 5fr/16g, double lumen length 55cm.usfda/ four digit notified ce approved, should have two guide wire 45cm & 80cm or more (logline iv.) peel-away sheath glide thru 5fr *10 cm,guide wire nitinol 80 cm,guide wire nitinol 45 cm,introducer needle 21 g*7 cm, syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 55cm, dressing statloock stabilization device (suture less), vascular catheter with metal guide wire,5fr triple lumen, size range 55cm or more (logline iv:)usfda/four digit notified ce approvedsyringe 12 ml, internal stylet, measuring tape, stat lock catheter stabilization device (suture less), introducer safety peripheral iv catheter 20g,micro introducer with vessel dilator, guide wire-50 cm nitinol, needle introducer 21 g, safety scalpel,end cap, "core biopsy instrument with compatible co-axial needle (automatic disposal ) should be bevel tip.should have adjustable penetration depth of 18mm and 25 mm with automatic and semi- automatic firing modes in single instrument/gun.should have fire ready indicator to reduce the risk of premature instrument firing.should have advanced echogenic technology for enhanced visibility in ultrasound.should be available with compatible coaxial needle in a single kit. instrument / gun size: 18 gauge, 16cm with coaxial needle size: 17gauge, total cannula length 12.9cm.", disposable bone marrow biopsy needleshould have ergonomic two- piece t-handle design.should have trocar tapered stylet point for easy coring of bone.should have triple crown cannula tip with 6 cutting cannula facets.should be available with marrow acquisition cradle with sample size verification marking.11gauge, 4 inch length", "absorbable surgical suture (synthetic)antibacterial coated sterilised needled suture (braided coated polyglactin/ polyglycolic acid violet) 1/2 circle ct round bodied40mm, gs needle, suture length 90 cm", bed side leucodepletion filters for blood transfusion (for 2 u