Tender For corrigendum : supply of 25vkoc001 c c - injector connection assly , injector holding flange assly. , pyrometric duct , expansion below , electronic governor-actuator , flex master con for dia 88.9-epdm , compensation sensor for exh.pyrometric duct , disc spring , piston ring , air valve , set of spare gasket & o rings , o ring dia 3 x dia 290 , o ring dia 3 x dia 260 , special seal , set of spares for abb vtc254 turbocharger , spare part kit for fw/sw heat exchanger , pt 100 converter with two threshold , ferquency preamplifier-engine speed , supply board , flash 64k card , communication module , pcmcia card , 16 analog input card , rtd input filed module , filed communication module , fuse 4a gg 10 38 , thermistor protection relay(aux415v ac) , injecting piping assly , set of seal for glacier filter , plug no4 , 25 cts , pyrometric duct bank b , expansion bellow , floating bush(te) , oil seal (190x160x15) , d/row sph rlr brg (100x165x52) , d/row sph rlr brg (120x180x46) , cap screw , portable temperature simulator 0-600 deg celcius , disc spring , release spring , gt2 coalescer filter panel , seal tape roll , barring gear assly - gali , type - gd , loctite 480 , crankcase pressure measurement assly , o ring , drilled cap plug - dn 12 , connecting straub metal grip d42 4 epdm , adjusting screw , injector tappet , gasket , injection pipe , o ring , p2-p4 by pass valve-gachot-dn125 , seal ring chord , expansion bellow , metallic gasket , cartridge , v band clamping , lub oil filling connection , rubber compensator , rubber compensator g0125 x 130 x 016 hks-g nbr gr deb , rubber compensator g0100 x 130 x 016 hks-g nbr gr deb , clamping collar , expansion bellows , metallic joint , o ring an 30 , 21a7 , gasket for lub oilcooler (nopv) , channel plate gasket , engine inlet thermostic valve , o ring , disc spring washer dia.56xdia.28.5x3 , disc spring washer dia.40xdia.21.5x2 , temperature sensor , silencer pads (fx4000) , lid seal for fx4000 , hex bolt , hex bolt , time delay relay(on delay) , elelctrical connnection laptop-engine controller , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , flex hose , repair kit for gali starter , set of seal for gali starter , solenoid valve-24v , main bearing assly , gasket , gasket , o ring , gasket , seal , impeller , 2 lips oil seal , bearing , mechanical seal eagle , o ring , bearing , cap plug , injector sleeve , o rind- ms 29513/238 , v 75 e , o ring - kalrez , inlet valve guide , gasket exhaust manifod , valve seat metallic ring , inlet valve , exhaust valve , rocker arm bush , metallic joint , rocker cover screw , piston ring - top - chrome , ceramique , piston ring - compression-g3-chrome , piston , gasket , set of gasket for hyd. motor , connecting axiflex metal gripd168.3 , epdm , gasket , service tool kit for oil mist detector , exhaust temperature sensor , o ring - ms29513/230 , 60c7 , o ring an26 , 60c7 , nozzle assly -9 x 0.52 x 148 , helicoflex joint hn100 , d17.4 1.8mm , sea water pump , joint type c with limiter , metallic joint , tc speed sensor , gasket rc , o ring d54 , 50x3 v70d , o ring an29 , 21a7 , gasket , hose , metallic joint , set of spares for air valve and actuator , set of spares for p2/p4 bypass valve , actuator service kit , fresh water temp sensor (rtd) , coupling assly cw , connecting cable (unitel way) , analog input field module type 170aaio3000+slave 170fnt11001 , lamp , hooter (electronic) , power switch , fuse 10x38 2a gg , pt 100 converter with two threshold , solenoid valve-safety stop , power fuse , 32a , rsp bearing safety card , icm safety stop card (4 channel) , frequency preamplifier (engine speed) , human machine interface , main bearing temp probe , connecting rod bearing temp probe , washer bsf , ring for casing , bushing
Tender For corrigendum : tender for supply of lockiconorganizationlockpinkiconsign in to unlock| send me onwhatsappmail|wishlistexport20days leftreagent kitsreagentsmicrobiology test kitsmedicinetesting equipment - phased array ultrasonic flaw detector 32-128 elements pr configuration with provision of additional 2 numbers of conventional ultrasonic channels , lithium iron battery pack rechargeable type minimum 70 wh having minimum operating time of 4 hours compatible for phased array ultrasonic flaw detector , external battery charger lithium iron battery pack compatible for phased array ultrasonic flaw detector , standard phased array probe , frequency-5.0 mhz , linear array , 64 elements , 0.5 mm pitch , total active aperture 32x10mm , 5 meter cable length , connector compatible for phased array ultrasonic flaw detector , standard phase array probe , frequency-7.5mhz , linear array , 16 elements , 0.5mm pitch , total active aperture-8mm x 10mm , 2.5 meter cable length , connector compatible to phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (26.67mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (48.26mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (73.03mm)axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (88.9mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (168.3mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (219.1mm)axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (273.1mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (26.67mm) circumferential outside diameter (cod) for axial weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (48.26mm) circumferential outside diameter (cod) for axial weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array pr
Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supplying and installation of medical equipment (c-arm with flat panel detector high frequency, high resolution) for various chc/phc & civil hospital centers, surat- under csr initiative by dgvcl 2025-26
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8