Web Analytics Made Easy - StatCounter

Resistance Temperature Detector Tenders

Get complete information related to latest Resistance Temperature Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resistance Temperature Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resistance Temperature Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :44286906 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For bid to ras supply of resistance temperature detector pt-100 (rtd) , k type thermocouple ( immersion length 650 mm) , k type thermocouple ( immersion length 400 mm)

CTN :45455729 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of personal protective equipment (ppe), electrical and mechanical safety items and safety detecting devices for various power plants of assam power generation corporation limited (apgcl). - supply of safety items, safety helmet (white colour), safety helmet (grey colour), safety helmet (yellow colour), safety helmet (blue colour), safety helmet (green colour), safety helmet ( red colour), safety electrical gloves 33 kv, safety electrical gloves 430 v, natural rubber gloves (chemical resistant), rubberized cloth apron chemical (acid/alkali) resistant, disposable latex gloves (in pairs), safety ear plug, safety belts mechanical, raincoat with reflector ( high quality and full set-pant and coat type), safety face shield, welding safety gloves, mechanical hand gloves ( heat and strain resistance), safety lifebuoy ring for operation and maintenance personnel at dam, life jacket for operation and maintenance personnel at dam, frp electrical rescue rods, safety glasses/goggles, welding face shield (could be attached with any standard helmet), gum boot number 5, gum boot number 6, gum boot number 7, gum boot number 8, safety shoes (number 4 ), safety shoes (number 5), safety shoes (number 6), safety shoes (number 7), safety shoes (number 8), safety shoes (number 9), safety shoes (number 10), warning/caution tape (100 m piece each), barricading cones with reflective tape, safety net (size: 10m x 5m), raincoat with reflector, gown type, size: m, raincoat with reflector, gown type, size: l, raincoat with reflector, gown type, size: xl, raincoat with reflector, gown type, size: xxl, reflective vest green (size: xxl), reflective vest green (size: xl), reflective vest red (size: xl), reflective vest orange (size: xl), portable gas detector (hc, o2, h2s, co, lel, methane), high rising extension aluminium ladder 20 feets, high rising extension aluminium ladder 30 feets, non contact high voltage detector with insulating rod, non contact high voltage detector (wrist type), foldable stretcher, safety shower and eye wash, arc flash suit, safety belt for electrical works

CTN :45047997 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply of life detector type - ii (q3)

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to

State Government

CTN :45353428 Due date: 04 Jun, 202604 Jun, 2026 7.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al

State Government

CTN :45353431 Due date: 04 Jun, 202604 Jun, 2026 10.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng

State Government

CTN :45353459 Due date: 04 Jun, 202604 Jun, 2026 10.87 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at opd/ipd building bissamcuttack rayagada vide addition/alterations letter no- 8078 dated 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction o

Central Government And Public Sector

CTN :45345523 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For supply of supply of resistance temperature detectors sheath length 320 mm at neriya station as per specification , supply of resistance temperature detector sheath length 490 mm at neriya station as per specification , supply of resistance temperature detectors sheath length 490 mm at neriya station as per specification , supply of bar stock drilled screwd thermowell at neriya station as per specifications , supply of bar stock drilled screwd thermowell at neriya station as per specification

CTN :45014326 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : supply of resistance temperature detector (rtd) (v2) (q3)
 Loading, Please wait...

Connect us via What's Up