Get complete information related to latest Scada Software Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scada Software Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scada Software Tenders.
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rectification and configuration of scadasoftware to upgrade the existing sas system with latest hardware synchronization of relays and other associated work at 220 kv s..
Tender For supply of ultrasonic level measurement system spares for scada system of bmc - dual channel ultrasonic level transmitter, ultrasonic level sensor units
Tender For (sh- provision for automatization and management system with microprocessor based control panel, online monitoring, wireless connectivity with complete cloud based scadasoftware storm pump house, at south extension u-turn underpass).
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rectification and configuration of scadasoftware to upgrade the existing sas system with latest hardware, synchronization of relays and other associated work at 220 kv ..
Tender For corrigendum : supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount
Tender For supply and upgradation of scadasoftware license for integration of electrical network at kallayi building and prefab building, technopark phase-i campus, thiruvananthapuram - supply and upgradation of scadasoftware license for integration of electrical network at kallayi building and prefab building, technopark phase-i campus, thiruvananthapuram.
Tender For corrigendum : survey, investigation, preparation of design, drawings, supply, erection, testing and commissioning of gravity pipe distribution network from delivery chamber (of phase-i work) and pressure pipe distribution network from bleeder (of phase-i work) with ms / hdpe pipes including sh,nh & railway crossing structures and all other appurtenant structures along the pipe distribution network and scada arrangements with compatible sluice valves, butterfly valves, flow meters, discharge control meters at each 20 ha outlet and air valves, scour valves wherever necessary in complete manner etc, for providing irrigation facility to an ica of 16000 ha in badami taluka, bagalkot district under kerur lift irrigation scheme phase 2 including supply of spares, accessories & tools including operation & maintenance of the entire system for five years from the date of successful commissioning on turn-key basis (indent no 2788)
Tender For bid to ras corrigendum : supply of degn sup inst test comm of water management system d d -pump set-minimum head 30 mtrs , power db with suitable for 1 working 1 stand by pumps , power db with suitable for 1 working 2 stand by pumps , plc hmi control panel with smps 1 working 1 stand by pumps , plc hmi control panel with smps 1 working 2 stand by pumps , inline electromagnetic flowmeter , smart pressure transmitter range 0-16 bar , pressure switch range 0-10 bar , pump set-minimum head- 15 mtrs , vertical pump set-minimum head- 15 mtrs , power db with suitable for 2 working 3 stand by pumps , plc hmi control panel with smps - 1 working 1 stand by pumps , plc hmi control panel with smps - 3 working 2 stand by pumps , pressure switch, range 0-10 bar , 1 pump set-minimum head- 10 mtrs , plc hmi control panel with smps for 1 working 1 stand by pumps , plc hmi control panel with smps for 1 working 2 stand by pumps , smart pressure transmitter range 0-16 , pump setminimum head- 22 mtrs , plc hmi control panel with smps for 1 working1 stand by pumps , ultrasonic hydrostatic level transmitter , magnetic float type level sensor , motorized valve with on off control 40nb , motorized valve with on off control 50nb , motorized valve with on off control 65nb , motorized valve with on off control 80nb , armoured cable 1. 1kv grade 3 core x 2. 5 sq. mm , armoured cable 1. 1kv grade 3 core x 4 sq. mm , armoured cable 1. 1kv grade 3 core x 6 sq. mm , cable tray , plc remote control panel with smps and suitable qty of relay boards , control panel with master plc ups , fiber optic cable 4 pair pvc , signal converter rs485 to fiber optic , signal converter ti port to fiber optic converter , cat 6 cable with pvc conduit , industrial grade 8 port lan switch , control room server with scadasoftware 2000 tags licensed copy , plc programming software licensed copy with laptop , installation testing and commissioning of complete system ) /bid number: gem/2026/b/7268901 * /dated: 05-03-2026 & & / bid document1 / 42
Tender For corrigendum : supply of redundant plc based control system of radial gate (# 02, # 03, # 04 &# 05) as per ts and sow enclosed , hot redundant scada system as per technical specification and scope of work enclosed. , non-redundant plc based control system for intake gate as per ts and scope of work enclosed. , mandatory spares for radial gate and intake gate control system as per ts & sow enclosed , installation, testing and commissioning as per scope of work enclosed(1set= 1 job)