Get complete information related to latest Solar Pumps Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Solar Pumps Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Solar Pumps Tenders.
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia
Tender For construction of pressurized pipe system to supply water for solar micro irrigation to deliver at farmers field up to 1 ha with a duty of 0.84 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for micro pressurized irrigation in distt. bilaspur in 135 ha. in kharif ( left side of bhaisajhar lift irrigation scheme. as indicated in index map), out of total gross command area, 135 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of bhaisajhar lift irrigation scheme as indicated in the index map for micro irrigation system without exceeding total power requirement for solarpumps with solar panel it includes all activities starting from investigation , planning ,design, drawing, construction of underground distribution network for micro irrigation system down to 1 ha chak in 8 ha consisting of providing, laying & fixing of all types of pressurized pipe lines with all necessary valves to serve as main line, branch line, distributaries, minors and sub-minors of pressurized irrigation system of bhishajhar lift irrigation project (to serve total cca not less than 135 ha in kharif ) including providing control at 4 ha and 2 ha with fixing multiple outlets with duty of 0.84 lit/sec/ha upto 4 ha and distribution network up to 1 ha chak, to serves the area as shown in index map with discharge of 3 times the specified duty at 1 ha chak including scada & successful trial run and commissioning and as per scope work and as directed by engineer-in-charge.. the work also includes formation of fpo as per company act/rule, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work. mou between agency and fpo to operate scheme after 05 years of mom and dl period and to arrange linkage facility to the fpo
Tender For construction of pressurized pipe distribution network lift irrigation scheme to supply water for irrigation to deliver at farmers field up to 1 ha with a duty of 0.70 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for pressurized irrigation by rotation in village kapua, block -patharia ,dist. -mungeli in 160 ha. in kharif (right side of khairi anicut as indicated in index map), out of total gross command area 270 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of khairi anicut as indicated in the index map for irrigation system without exceeding total power requirement for solarpumps with solar panel of 100 kwp.it includes all activities starting from survey, investigation, designing, estimating costing, procurement, construction, laying, installing, energizing, etc. of pumping system, rising and gravity mains, main line, branch lines, distribution network, controlling and regulation system , scada work with automation etc. for supply of filtered water for irrigation under pressure. the work also includes construction of chowkidar quarter, pump house, installation of solar power plant and sub station with transformer of required capacity by liasoning with cseb, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work
Tender For construction of pressurized pipe distribution network lift irrigation scheme to supply water for irrigation to deliver at farmers field up to 1 ha with a duty of 0.70 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for pressurized irrigation by rotation in village bandhapali, baghanpur, bundeli , baragaon and barpali block sarangarh ,dist. sarangarah-bilaigarh in 150 ha. in kharif (madhavpali anicut as indicated in index map), out of total gross command area 270 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of madhavpali anicut of dist- sarangarah-bilaigarh as indicated in the index map for irrigation system without exceeding total power requirement for solarpumps with solar panel of 110 kwp.it includes all activities starting from survey, investigation, designing, estimating costing, procurement, construction, laying, installing, energizing, etc. of pumping system, rising and gravity mains, main line, branch lines, distribution network, controlling and regulation system , scada work with automation etc. for supply of filtered water for irrigation under pressure. the work also includes construction of chowkidar quarter, pump house, installation of solar power plant and sub-station with transformer of required capacity by liasoning with cseb, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work.
Tender For aic/aed/niet-85/26-27/gr_2 - installing of solarpumps from rongiladi village 1 unit and narayangarh majhi para 1 unit under kashipur gp and lohet kanthalpara 1 unit and cheliya kamarpara 1 unit under kalidaha gp under kashipur dev. block in the purulia district.
Tender For package no. up 67135: regarding the widening and improvement of the patwadh-basuhari link road (chainage 0.00 to 61.500)—in exchange for the 45.295 hectares of forest land affected by the project (as identified by the forest department)—non-forest land has been made available across 7 parcels; the scope of work includes site fencing, installation of solarpumps, borewells, etc.
Tender For package work 1. providing and laying gi pipeline from mallikarjun temple to vedaprakash motgi house and near raghavendra guttedar house at ward no 01 and 02 and drilling borewell in kalagi town. 2.installation of solarpumpset to the existing borewell at the swm site in kalagi town panchayat limit