Get complete information related to latest Sole Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sole Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sole Plate Tenders.
Tender For corrigendum : supply of handpump spare parts at pune zp - supply of handpump spare parts, die set 12mm with handle & bits, hydraulic vice 32 mm., heavy duty clamp 32 mm, heavy duty clamp 65 mm, connecting rod vice, pipe lifter spanner for 32mm n.b.pipe., pipe wrench 300 mm, pipe wrench 450 mm, pipe wrench 600 mm, pipe wrench 900 mm, double ended open jaw spanner 17 * 18 in c.v. steel, hacksaw frame, pump bucket (nitrile) for deepwell hand pump(is: 15500 part 7), sealing ring for deepwell handpumps (is: 15500 part 7), hex nut with bolt m 12 * 40, handle axle along with nut & washer for deepwell hand pump (is: 15500 part 4), single side shielded bearing confiming to is: 15500 part 4 suitable for above handpumps, chain nut with bolt m-12x40 (is: 15500 part 4), chain with coupling for deep well hand pump, head for deepwell hand pump (is: 15500 part 4), third plate suitable for deepwell hand pump (is: 15500 part 4) (im-ll), water tank for deepwell hand pump (is: 15500 part 4) (im-ll), connecting nrod of 12 mm dia. x 3 mtr. length, i.s.i.marked galvanized steel tubes as per i:s 1239 ( part-1) /2004 amdt.1 to 4 scrwed at both ends as per i:s 554/1999 ( reaffirmed 2004) . one end socketed with isi marked socket as per is:1239 ( part -ii)/1992 ( reaffirmed 2003) and other end protected with plastic thread protector medium class , bore size (nominal)diameter 32 mm , length 3 meter, cylinder assembly i.m.ii, cylinder body with brass liner for deepwell hand pump (is: 15500 part 5), reducer cap for deepwell hand pump (is: 15500 part 5) (im-ll), upper valve along with rubber seat for deepwell hand pump (is: 15500 part 6) (im-ll), upper valve assly suitable for deep well hand pump (im-ll) (is: 15500 part 6) (im-ll), lower valve assembly i.m.ii, hacksaw blade (high speed steel), spacer g.m. i.m.ii, rubber seat lower valve (im-ll), rubber seat upper valve (im-ll)
Tender For rewinding of 7.5 hp submersible motor including cost of cooper wire, brass bush, thrush plate, lifting of motor and pump with the help of chain pully, & manual labour & refitting after complete repair, loading unloading & carriage charges, testing of motor after complete & less cost of old defective material complete job (job) /7.5 hp submersible motor job (job) / sanp ki nagli and lakhuwas
Tender For tender for pump spare parts & repairs/ bearing ,6309/pump bearings 6309 ,carriage charges of pump from workshop to site after repair / at w/w ,gailn plate new of ms material / glain plate ,labour of pump set opening and fitting./labour charges ,pump housing including bearing sheet made new by welding brass. / 40 hp pump shaft bearing and sheet grinding ,charges ,main bush new of steel / pump bush steel ,making new impeller ring / making of impeller rings
Tender For supply of ceiling materials and other works at lok bhawan jaipur - providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(cost of aluminium snap beading shall be paid in basic item.)with float glass panes of 8 mm thickness, providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled and glazed shutter 25 mm to 40 mm thick : is 710- 1976 marked 12mm thick teak ply bwr both side, providing & fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m-15 grade : ivory coast wood grade i, providing and fixing double action hydraulic floor spring of approved brand and manufacture is : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece m.s. with brass cover plate
Tender For corrigendum : 6.2 mm thick composite grooved rubber soleplate as per rdso drg. no. t-6618 for 60 kg (uic) rails and conforming to irs specifications for cgrsp for placing beneath rails, serial no. t-55-2025 (revision-01) with latest alt. & spn. note: latest alteration/corrigendum wherever used will mean the alterations/corrigendum to drg/spec. up to the closing of tender will be applicable. [ warrantyperiod: 96 months after the date of delivery ][ rate of supply 273602 units per month , commencement time allowed -2 month ]
Tender For supply of composite grooved rubber soleplate(cgrsp) - 10mm thickness for use with wider psc sleeper to drawing no. rdso/t-8746 suitable to rails 60 kg(uic) / 60e1 & 52 kg drg: (rdso) rdso/t-8747 alt-1 spec: (rdso) t- 55-2025 revision-01 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of tubes and work of insitu retubing as per atc d d - aluminium brass seamless cold drawn tubes , end plate having size of o.d. 267mm, thickness 16.5mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 205mm, thickness 32mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 330mm, thickness 25mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 260mm, thickness 40mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , baffles having size of o.d. 205mm, thickness 04mm both end chamfer and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 25nos. , baffles having size of o.d. 260mm, thickness 04mm both end chamfer and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 19nos. , work of complete in situ re tubing of old damaged tube cooler of lube oil cooler of 210mw unit no. 3 and 4 as per atc , work of complete in situ re tubing of old damaged tube cooler of working oil cooler of 210mw unit no. 3 and 4 as per atc ) /bid number : gem/2026/b/7336822 * /dated: 14-04-2026 & & / bid document 1 / 12
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For fabrication & supply of various 19 items - flap axial bush pin, label right and left for type-i and type-ii , label front for type-i and type-ii, label for terminal wire, switch mounting holder tube with tin plting, switch mounting holder with washer tin plating, contact holder mounting base plate with tin plating, connector nut with tin plating, taper (conical) spring, contact screw top with gold plating, switch body square tube with tin plating, bottom cover with tin plating, brass side plate with tin plating, contact button bottom with gold plating, eyelet (riverts) with tin plating for proximity switch, top cover and bottom cover, switch body square tube etc..