Web Analytics Made Easy - StatCounter

Solution Pump Tenders

Get complete information related to latest Solution Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Solution Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Solution Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45601093 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : supply of 1250 amps bfw pump motor feeder , 1250 amps fire water pump motor , 1250 amps benfield solution pump motor feeder , 1250 amps 100 bfw pump motor feeder , 1250 amps pcc feeder , 1250 amps raw water feeder , installation and commissioning

Central Government/Public Sector

CTN :45544077 Due date: 23 Jun, 202623 Jun, 2026 1.60 Crore
Tender For procurement of pump spares - cover plate liner e4018ro55, impeller part.no.b1127a05, expeller ring part no. b029r55 (sp. for 2/1.5 bah warman pump), shaft sleeve part no. b075c21 ( sp. for 2/1.5 bah warman pump), lip seal part no. b090s10 ( sp. for 2/1.5 bah warman pump), clamp washer b011e63 for 2/1.5 warman pump, frame plate stud with 2 plain nut- part no. b039me63, adjustmet screw with 3 nut & 2 washer b001me62( spares for warman pump model, 1.5" bah centrifugal slurry pump), shaft sleeve o ring part. no. b109s10 ( sp. for 2/1.5 warman pump), impeller o ring b217s10 (2/1.5 bah, 1.5/1 bah warman pump spare), labrinth lock nut part no. b061e62 ( sp. for 2/1.5 bah warman pump), end cover part no. b02410d21 ( sp. for 2/1.5 bah warman pump), shaft key part no. b070me05 ( sp. for 2/1.5 bah warman pump), end cover shim part no. b025p10 ( sp. for 1.5/1 bah warman pump), piston ring for 2/1.5 bah warman pump - b108g02 ( sp. ), end covert set screw part no. b027me62 ( sp. for 2/1.5 bah warman pump), weir accumin 120lc mobil grease xhp222 ctn 10, part no wa120y-10, impeller for 2/1.5 bah,5vo, alloy, part no. b15127a05 ( spare for warman pump), frame plate liner part no. b15036mr55 ( sp. for 2/1.5 bah warman pump - duplicate code - use 45-4309), frame plate liner stud part no. b026me62( sp. for 2/1.5 bah warman pump), metal impeller 6v part no.c2058a05 (sp.for warman 3/2 pump), expeller - c028a05, expeller ring c029r55 for 3/2cah sp, frame plate liner c2036mr55 (3/2 cah warman pump spare), lip seal c090sqs10 (sp.for 3/2 cah warman pump), clamp bolt 3/2 & 4/3part no.c012me62 (sp.for warman 3/2 & 4/3 pump), frame plate stud with 2 nuts part no.c039me62/63 (sp.for 3/2 cah warman pump ), frame plate liner stud with nuts c026me62 steel, end cover partno.c02410d21 (sp.for 4/3 & 3/2 warman pump), labyrinth -part no.c06210d81 (sp.for 3/2 & 4/3 warman pump), bearing housing c004mg01 (4/3 cah, 3/2 cah warman pump spare), metal impeller for 4/3 6v part no. d3058a05 ( spare for warman pump ), expeller ring pt:no.cam029r55 4/3 warman pump, impeller o ring part no. d064s10 sp. for 4/3 warman pump, pu impeller for 6/4 dah, 5vc rubber part no. e4147u38 ( spare for 6/4 warman pump, expeller part no. b028d21 (sp. for 1.5/1 bah warman pump), expeller ci 6/4dam dam028, expeller ring part no.dam029mr55 (sp.for 6/4 warman pump), frame plate liner stud with one nut - dam026me62 (sp.for 6/4 dah warman pump), adjusting screw with 3 nuts and 2 washer part no. d001me62 ( spare for 6/4dah warman slurry pump), frame plate bolt 1 nut d034me63 (sp.for 6/4 dah warman pump), clamp washer d011e63 ( sp for 6/4 dah), clamp bolt & one nut ptno.d012me62, throat bush e4083r55 (6/4 dah warman pump spare), shaft dam073me05 (6/4 dah warman pump spare), lip seal d090sqs10 (sp.for pump 6/4 dah), cover plate liner part no.b1017 (sp.for 1.5/1bah warman pump), frame plate liner part no. b1036mr33 ( sp. for 1.5/1 bah warman pump), clamp bolt part no. b012me62 ( sp. for 2/1.5 bah warman pump), cover plate bolt with 2 nut-p.no-b015me62 sp: for 2/1.5 solution pump( sapre for warman pump ), grease retainer ci b 046, bearing hsng b004mg01 for 2x1.5bahp, intake joint ring b15060s01, labyrinth b062 10d81, shaft sleeve c075c21, shaft sleeve c075c21 for 4/3 & 3/2 pump, shaft ptno.c073me05 for 3/2 - pump spare, clamp washer part no. c011e63 ( spare for 3/2 & 4/3 warman slurry pump), adjusting screw with 3 nut and 2 washer c001me62 sp for 3/2, cover plate bolt 2 nuts- c015me63 for 3/2 cah, saft sleeve o ring c109s10 (3/2 cah warman pump spare), impeller o ring ptno.c217s10 (sp.for 3/2 warman pump), labyrinth lock nut ptno.c061e62 (sp.for 3/2 or 4/3 warman pu, grease retainer part no. c046d21 ( spare for 3/2 warman slurry pump ), labyrinth ptno. c06210d81 sp for 3/2 & 4/3 warman pump, shaft key-c070me05 for 3/2 cahpump, end cover gasket (shim set) c025, end cover set screw part no.b027me62 (sp.for warman 3/2 & 4/3 pump), joint ring intake c2060s01 (sp.for

Central Government/Public Sector

CTN :45354574 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : supply of p-353 'o' - ring 500 x 5 mm part no: -412.02 pos no: - 158 material: - epdm80 peroxide pump type: -chtr , p- 353 'o' - ring 460 x 4 mm part no: -412.01 pos no: -104 material: -viton pump type: -chtr 5/1+ 2 make: - , p353 a/b taper roller bearing 31312 / df part no. 320 for lean solution pump -1353 a/b-p235 3. a/b) .

State Government

CTN :45524857 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For procurement of submersible slurry/ sludge pump for cmr handling system at unit 5&6 at cstps, chandrapur.

Central Government/Public Sector

CTN :45293060 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; overhauling of pump cartridge assembly of p-353, gv lean solution pump of ammonia plant at rcf, thal unit; buyer

Central Government/Public Sector

CTN :45064384 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of spares for lean solution pump - o' ring for shaft sleeve, part no. 430.00 . moc : viton; for lean soln pump pc-4-4r , model : mc 100/4 ,sr. no. 60019; manufacturer : m/s sulzer pumps, o' ring , part no.430.02 , moc : viton; for lean soln pump pc-4-4r , model : mc 100/4 ,sr. no. 60019; manufacturer : m/s sulzer pumps., 'o' ring part no. 430.03. material : viton. suitable for lean soln pump pc-4-4r , model : mc 100/4 ,sr. no. 60019, manufacturer : m/s sulzer,, 'o' ring , part no.430.05 , moc : viton; for lean soln pump pc-4-4r , model : mc 100/4 ,sr. no. 60019;, grooved nut , part no. 462.00 , moc : steel for lean soln pump pc-4-4r , model : mc 100/4 ,sr. nos. 60019 / 60321 / 60026, make : m/s sulzer pumps india ltd., ring (ci), p.no.320.03 , for lean soln pump pc4-4r , model : mc 100/4 ,sr. nos. 60019 / 60321 / 60026, make : m/s sulzer pumps india ltd., cylindrical roller bearing no. nu 312 ecj,for pc-4 pump of ammonia-1 plant make: skf cage: steel, single row taper roller bearing, no. 31312 j2/q df, (1 pair = 2 nos of bearings arrange back to back) for pc-4 pump of ammonia-1 plant bearing, shaft part no.091.00 , moc : ss410 with locknut part no. 462.00, moc: steel (qty: 2 nos); lock washer part no. 510.00, moc: steel (qty: 2 nos); coupling key part no. 444.00, moc: en-8 (qty: 1 no.); key impeller last stage part, balance drum part no. 068.00 material : 431, deflector part no.140.00 material : ss 316 , for lean soln pump pc-4-4r ,, shaft for ammonia reflux pump p-552 part no.: 210.01 moc: ss316 pump, wearing ring stationary, pt.no: 502.01 , moc: 316 / cf-8mhf suitable for ammonia reflux pump p-552 a/b ,, fan for process condensate pump of mp stripper (p-101 a/b) of ammonia-1 plant as per the, helicoil insert for process condensate pump of mp stripper (p-101 a/b) of ammonia-1 plant as, 'o' ring , part no. 430.01 , moc : viton; for lean soln pump pc-4-4r, deflector, part no.140.01, moc: ci, for lean soln pump pc-4-4r,, deflector part no. 140.02 material : ss 316 ,for lean soln pump pc-4-4r, bearing isolator for ammonia water circulation pump (p-551) of ammonia-1 plant as per the, bearing isolator for ammonia water circulation pump (p-551) of ammonia-1 plant as per the, neck bush for process condensate pump of sgc turbine (p-403 a/b) of ammonia-1 plant as per, impeller nut for process condensate pump of sgc turbine (p-403 a/b) of ammonia-1 plant as per, thread insert for process condensate pump of sgc turbine(p-403 a/b) of ammonia-1 plant as, mpeller wear ring , pt.no:503 .01 , moc: 316/cf-8m suitable for ammonia reflux pump p, shaft coupling , pn-18.00 , moc : bs 970/080 m41 suitable for effluent pump ( storage ) , make : sulzer pumps india, impeller nut for process condensate pump of mp stripper (p-101 a/b) of ammonia-1 plant as per, o-ring for process condensate pump of mp stripper (p-101 a/b) of ammonia-1 plant as per

CTN :44891328 Due date: 30 Apr, 202630 Apr, 2026 NA
Tender For miscellaneous works in thermal-2 - miscellaneous works in thermal-2, the work shall be carried out on a manday basis and includes collection, segregation, and shifting of metallic and non-metallic waste materials from the thermal-2 building premises. the activities cover handling of rusted metallic items, structural scrap, insulation materials, oil sludge/oil slick, mud, debris, and other miscellaneous scrap lying at various locations such as the ground floor near boiler area, pipe rack area, tg floor area, cooling tower area, and other surrounding premises. the work also includes bringing down waste materials from different floors of boiler units 1, 2, and 3 to ground level and consolidating them at a designated location. all manpower, tools, tackles, and equipment shall be provided by the contractor. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., the work shall be executed on a manday basis and includes loading and unloading of segregated metallic and non-metallic scrap/waste materials within the fact ud / petro plant premises as directed by the engineer-in-charge. all required manpower, tools, tackles, and handling equipment including concrete lump breakers shall be arranged by the contractor. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., transportation of scrap and waste materials loaded under sl. no. 2 from cpp - pd premises to the designated scrap yard, waste dumping area, or any other location within the fact ud / petro plant premises, as directed by the engineer-in-charge. the contractor shall provide a suitable truck having carrying capacity up to 2 tonnes for the purpose.the rate per trip shall be inclusive of all charges such as vehicle hire, driver wages, fuel, and any other incidental expenses.copies of the relevant scrap dispatch advice and weighbridge report shall be submitted by the contractor for each lot of material transported. the quantity indicated is tentative and payment shall be made based on actual number of trips certified by the engineer-in-charge., the work shall be performed on a manday basis and includes moving and rearranging used materials and equipment parts such as valves, pumps, flanges, motors, radiators, drums, welding sets, structural items, roof sheets, and other related materials stacked at various locations including cpp building north and south entrance areas, boiler feed pump area, tg floor area, and other specified locations, as instructed by the engineer-in-charge. required cleaning materials, rigging materials, tools, tackles, and manpower shall be arranged by the contractor. the eot crane at the tg floor may be used free of cost, subject to availability. loading and unloading for shifting within the petro plant premises shall be in the contractor s scope. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., the work shall be carried out on a manday basis and includes removal of vegetation from the outer side walls and top platforms of cooling tower cells, removal of vegetation from the side walls and floor of the cooling tower pond, and removal of accumulated mud, slurry, and other unwanted materials within the cpp cooling tower area. all manpower, tools, tackles, and equipment required for execution shall be arranged by the contractor. cleaning of all four cooling tower cells shall be treated as a single activity., the work shall be executed on a manday basis and includes thorough cleaning of the furnace oil (fo) pump house area. furnace oil spillage on floors, including areas beneath oil heaters, around pumps, condensate drains, and adjoining areas, shall be removed by spreading sawdust and collecting the oil-soaked sawdust for proper disposal as instructed by the engineer-in-charge. sawdust, cotton waste, manpower, tools, and all other materials required for complete execution of the work shall be arranged by the contractor. payment shall

corporations/Associations/Others

CTN :44561650 Due date: 15 Apr, 202615 Apr, 2026 NA
Tender For providing of operation and maintenance power house / power plant - cleaning of main drain various size including removal of deposited earth, bricks bats, ash and and waste refuses sludge, cleaning of grass/jungle along both side of drain completely drain of width upto 0.6 м. cartage of ash/malwa/lt/dush etc. by tractor trolley upto distance of 2km including loading on tractor-trolley with lead of 100.00m and lift upto 1.5 m, cartage unloading complete including cost of all labour, t&p tractor-trolley driver etc. (the rates will be applicable to net quantities after deduction of prescribed percentage for voids mentioned in the specification under subhead "carriage of materials") upto 1 km providing lcb. machine including cost of driver, helper, t&p and fuel charges complete for different works. cleaning of buda nala and carriage of ash malwa sit/slush etc. by tractor trolley up distance of 2 km including loading on tractor -trolly with lead of 100 m and lift upto 15 m. cartage unloading complete including it of all labour t&p hactor trolly driver (the rate will be applicable to nei quntities after deduction of voids mentioned in the specification under subhead carriage of rearranging of stone in check dam p suitable height by manual mean including carriage and dressing of stone boulder from coal handling arra also include removing of jupto 30 mete hiring charges of dewatering pump having capacity atleast shp7.shp with hoperator, fuel, installing, all tap et sepration of oil hom drain by m mean (upto 500 mm depth).
 Loading, Please wait...

Connect us via What's Up