Get complete information related to latest Spreader Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spreader Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spreader Tenders.
Tender For corrigendum : supply of set of spreader sp 5250 (art no. 150.012.324) with pulling attachment set pas 02 (art no. 150.182.274), pulling chain set pcs 01 (art no. 150.582.152) & cutting tip set cts 01 (art no. 150.006.474), details as per attached specifications. make: holmatro [ warranty period: 24 months after the date of delivery ] ]
Tender For corrigendum : supply of set of spreader sp 5250 (art no. 150.012.324) with pulling attachment set pas 02 (art no. 150.182.274), pulling chain set pcs 01 (art no. 150.582.152) & cutting tip set cts 01 (art no. 150.006.474), details as per attached specifications. make: holmatro [ warranty period: 12 months after the date of delivery ] ]
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For corrigendum : providing of custom bid for services - rotation and replacement of 200nb and 300 nb ci and ms pipeline of esp hopper and bottom discharge line vacuum line ash slurry disposal line during overhauling of unit 4 210 mw btps parichha
Tender For corrigendum : supply of actuators for high pressure water to draghead , actuators for hp jp1 inlet , actuators for hp jp2 inlet , actuators for hp jp1 discharge , actuators for hp jp2 discharge , actuators for hp jp serial valve , actuators for hopper loading line , actuators for bd3 ps top flushing , actuators for bd2 ps top flushing , actuators for bd1 ps top flushing , actuators for bd3 sb top flushing , actuators for bd2 sb top flushing , actuators for bd1 sb top flushing , actuators for bd3 ps bottom flushing , actuators for bd2 ps bottom flushing , actuators for bd1 ps bottom flushing , actuators for to jetnozzle self-emptying line , actuators for to jetnozzle self emptying line , actuators for deaeration valve , actuators for tank to stage 1 , actuators for tank to stage 2 , actuators for tank to stage 3 , actuators for tank to stage 4 , actuators for jet system stage 1 , actuators for jet system stage 2 , actuators for jet system stage 3 , actuators for jet system stage 4 , actuators for ejector discharge overboard upper , actuators for jw supply to tank ejector , actuators for flushing discharge , actuators for gland pp inlet , actuators for gland discharge , actuators for bypass diapgrahm , actuators for fp tw tank , actuators for gs pumps inlet , actuators for emcy fifi pump inlet , service charges for replacement of actuators