Tender For supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : supply of ht and lt breaker spares - sc210290424 mccb, model-dm16, rating -1.6a,40 deg c ui 690v, 50 or 60hz, icu-65ka, ics-75 percent icu, instantan- 19a, is 13947-2 iec 60947-2, utilisation category-a, with limit switch landt or equi , sc210290427 mccb, dn2- 160h3,63a landt or equivalent , sc210170054 mccb,make- landt model dm100,rating-25a 40 deg c,ui- 690v,50 or 60hz,icu -65ka,ics-75 percent,instantan-300a,is 13947-2 or iec 60947-2,utilisation category-a,with limit switch landt or equi , sc210290425 mccb,model-dm16,rating - 7.5a 40 deg c, ui 690v, 50 or 60hz, icu-65ka,ics-75 percent, instan- 90a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290426 mccb,model- dm16,rating -5 a,40 deg c ui 690v, 50 or 60hz, icu- 65ka,ics-75 percent icu, instan-60a,is 13947-2 or iec 60947-2,utilisation category, with limit switch landt or equi , sc210170088 mccb,model-dm160,rating -160 a,40xc ui 690v,50 or 60hz, icu-65ka, ics-75percent icu,instan-1920 a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290429 mccb ,model- dm100,rating -80 a,40xc ui 690v,50 or 60hz,icu-65ka,ics- 75percentage icu,instan-960 a,is 13947-2 or iec 60947- 2,utilisation category -a,with limit switch landt or equivalent , sc210290428 mccb , model-dn3-400m, rating -400a, ui 415 or 440v, 50 or 60 hz, u 8kv, icu - 50ka, ics 100percent icu, cat - a,is or iec 60947-4,with limit switch landtor equi , sc050130075 power contactor, 3 pole, type no mnx 80, rating 80a, coil voltage 110v ac for chp,with add on block make-landt , sc050130064 u power springchargingmotor, 240v ac for chp, make - landt , sc050130084 contactor,3 pole, type no mnx 140,rating 140a, coil voltage 110v ac for chp,with add on block make - landt , sc050130056 contactor, 3 pole, type no mnx 50, coil voltage 110v ac for chp,with add on block make - landt , sc050150366 power contactor mnx265, with add on block,265 a 415 v 3 pole 2no plus 2nc make - landt , sc050150365 power contactor mnx110, 230 ac coil supply,110a,415v, with add on block, 2no plus 2nc make - landt , sc050150367 power contactor, 3 pole, type no mnx 50, with add on block, coil voltage 230v ac for chp. make - landt , sc050150358 contactor,mno 40e, coil voltage 110,4no 4nc make - landt , sc050150359 contactor, mno 31e,coil voltage 110 v ac make - landt , sc050150360 contactor,mno 22e, coil voltage 24v dc make - landt , sc050150364 contactor,mxo 22e,coil voltage 110vdc, ac-15, ue 415v - ie4a,ui 690v, lth-10a make - landt , sc050150363 contactor,mxo 22e, 220vdc, with add on block make - landt , sc050150362 contactor,mx0 40e, 220vdc, with add on block make - landt , sc050150361 contactor,mx0 31e, 220vdc,with add on block make - landt , sc210290423 mpcb, 415v, rotary type, thermal magnetic, 1-1.6 a, mog-h1-0401, make - landt or equivalent , sc210290419 rcbo,415v, 32a,4 pole,100ma make - landt or equivalent , sc210290420 rcbo,415v, 32a,2 pole, 32ma make - landt or equivalent , sc210290422 rcbo,415v, 32a,4 pole,32ma make - landt or equivalent , sc210290421 rcbo, 415v, 32a,2 pole, 100ma make - landt or equivalent
Tender For corrigendum : stripped stator of hitachi hs-15250a tm, along with cutting of lugs and repair of pe & ce side.scope of supply as per plw/hitachi-mf/stripping,rev-1,dated 25.04.2026 asper specification no.4tms.095.036(rev-1) & drawing no. 10p.702-107,alt-v. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]