Web Analytics Made Easy - StatCounter

Suction Equipment Tenders

Get complete information related to latest Suction Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Suction Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Suction Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40768243 Due date: 22 Jul, 202522 Jul, 2025 29.24 Crore
Tender For corrigendum : supply of group tender for hospital equipment for various department[ turnkey basis] - endoscope set , pure tone audiometer , videonystagmographic machine (vng) , oae screener , basic ent examination units with motorized patient chairs and microscope , mobile booth for audiometry , ent opd examination set , assorted diagnostic set for ent , b.p. apparatus , weighing machine adult , stethoscope , ophthalmoscope , led x ray view box , spirometer , multipara patient monitor , vital sign monitor , defibrillator with ecg monitor , pulse oximeter , syringe infusion pump , volumetric infusion pump , ventilator-high end , transport ventilator , transport monitor , laryngoscope , ambu bag , 12 channel ecg machine , tmt machine (stress test system) , ambulatory bp monitor , holter system with work station etc...

State Government

CTN :40616503 Due date: 30 Jul, 202530 Jul, 2025 8.00 Crore
Tender For corrigendum : surgical items (918 items) - suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, mucus extractor sterile clear transparent container antibacterial filter soft, kink resistant pvc tubing tube size 10 fg; length 40 cm (min.) capacity 25 ml, nasal oxygen cannula (set), twin bore (accessory forcompressed air breathing) all sizes (adult) soft and kink resistant pvc tubing multichannel / star lumen to preventing accidental kinking twin bores should ensure equal volume of oxygen to both air passages connector for easy connection to the oxygen source tube length 200 cm, nasal oxygen cannula (set), twin bore (accessory forcompressed air breathing) all sizes (pediatrics) soft and kink resistant pvc tubing multichannel / star lumen to preventing accidental kinking twin bores should ensure equal volume of oxygen to both air passages connector for easy connection to the oxygen source tube length 200 cm, ryles tube / nasogastric tube (p.v.c.) with radio opaque lining. size: 10 soft, kink resistant pvc tubing for atraumatic intubation closed distal end should be coned with radio opaque material for accurate intubation four lateral eyes for greater efficiency radio opaque line marking at 50, 60, 70 cm from tip colour coded funnel with luer connector / closure length 105 cm, ryles tube /
 Loading, Please wait...

Connect us via What's Up