Web Analytics Made Easy - StatCounter

Suction Equipment Tenders

Get complete information related to latest Suction Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Suction Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Suction Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41841056 Due date: 28 Oct, 202528 Oct, 2025 NA
Tender For bid to ras corrigendum : supply of est of drone training and repair laboratory g g---cnc cutting machine , 3d scanner , pid tuning stand testing rig , thrust stand , power tool with mount board , total tool kit , battery universal discharge tester , radio dev tool , battery charger ultra power 1200w 08 channel 2 to 6s , microscope set 4k hd , dc regulated power supply 30v,10 amp , lithium bty spot welder machine , connector, heat shrink tube, flame proof enclosure , soldering station , esc debugging tool , digital vernier calliper 300mm , telemetry device pixhawk cube 6c , digital multimeter , mini bench drill machine , weight machine , double sided tape 3mm , 3d printing pen touch play , esd glove 20 pairs , glue gun with stick , threading tool kit 40 pcs set , heat shrink tube , usb type c 5 in 1 hub , laser level measure , servo tester , data cable type c , data cable type a to micro usb

corporations/Associations/Others

CTN :42381175 Due date: 08 Nov, 202508 Nov, 2025 NA
Tender For supply of lignite flame monitor, integrated type , scanner cable with plug

corporations/Associations/Others

CTN :42430361 Due date: 11 Nov, 202511 Nov, 2025 NA
Tender For procurement of retractor assembly for hea igniter 210mw fss system in unit i ii and iii and 5 pin connector mm thread male and female for safe flame scanner

Central Government/Public Sector

CTN :40975233 Due date: 25 Oct, 202525 Oct, 2025 NA
Tender For bid to ras corrigendum : supply of cables for various projects - l430419509103001 2p x 1 point 5 sq mmp by o shielded ins cable pack 1 to stores , l430419509103002 4p x 0 point 5 sq mmp by o shielded ins cable pack 1 to stores , l430419509103003 12p x 0point 5 sq mmp by o shielded ins cable pack 1 to stores , a430419509103004 4px0 point 5 sq mmo bya shield unarm ins cab pack1 to stores , l430419509105001 2c x 2 point 5 sq mmarm control cable pack 2 to stores , l43041950910500 2 5c x 2 point 5 sq mmarm control cable pack 2 to stores , l430419509105003 7c x 2 point 5 sq mmarm control cable pack 2 to stores , l430419509105004 12cx 2 point 5 sq mmarm control cable pack 2 to stores , l430419509106001 3c x 2 point 5 sq mm cu xlpe power cable pack 3 to stores , l430419509106002 3c x 16 sq mm al xlpe power cable pack 3 to stores , r61180600366 2p x 0 point 5sq mm thermocouple extn cable kx type a pack 4 to stores , r61180600367 2p x 0 point 5sq mm thermocouple extn cable sx type b pack4 to stores , l182349509107001 12p x 1 point 31 sq mm extn cable kx pack 5 to site , l430619509102001 8p x 1 point 31 sq mm extn cable kx pack 6 to stores , l430919509102001 8p x 1 point 31 sq mm extn cable kx pack 7 to stores , l430719509102001 8p x 1 point 31 sq mm extn cable kx pack 8 to stores , l430419509101001 2px1 point 31 sq mm p by o shielded flame scanner cable pack 9 to stores , l173219509101001 2px1 point 31 sq mm p by o shielded flame scanner cable pack 10 to site , l1732s9509101001 2px1 point 31 sq mm p by o shielded flame scanner cable pack 10 to stores , l182349509108002 4p x 0 point 5 sq mm ptfe inst cable g pack 11 to site , l182349509108003 8p x 0 point 5 sq mm ptfe inst cable g pack 11 to site , l182349509108004 3c x 2 point 5 sq mm ptfe control cable pack 11 to site , l182349509108005 5c x 2 point 5 sq mm ptfe control cable pack 11 to site , l173219509108001 2p x 0 point 5 sq mm ptfe inst cable g pack 12 to site , l173219509108002 4p x 0 point 5 sq mm ptfe inst cable g pack 12 to site , l173219509108003 8p x 0 point 5 sq mm ptfe inst cable g pack 12 to site , l173219509108004 3c x 2 point 5 sq mm ptfe control cable pack 12 to site , l1732s9509104001 2p x 0 point 5 sq mm ptfe inst cable g pack 12 to stores , l1732s9509104002 4p x 0 point 5 sq mm ptfe inst cable g pack 12 to stores , l1732s9509104003 8p x 0 point 5 sq mm ptfe inst cable g pack 12 to stores , l1732s9509104004 3c x 2 point 5 sq mm ptfe control cable pack 12 to stores , l173219509109001 2p x 0 point 5 sq mm ptfe extension cable pack 13 to site , l1732s9509105001 2p x 0 point 5 sq mm ptfe extension cable pack 13 to stores

CTN :42362937 Due date: 03 Nov, 202503 Nov, 2025 NA
Tender For procurement of housing assembly with vaned diffuser for hfo, ldo oil guns and ignitor rod, guide tube for hfo, guide tube for ldo, coal concentrator for primary air coal pipe, ss wire braided flexible hose assembly for flame scanner-5 items

corporations/Associations/Others

CTN :42335217 Due date: 03 Nov, 202503 Nov, 2025 NA
Tender For procurement of housing assembly with vaned diffuser for hfo, ldo oil guns and ignitor rod, guide tube for hfo, guide tube for ldo, coal concentrator for primary air coal pipe, ss wire braided flexible hose assembly for flame scanner 5 items

State Government

CTN :41989053 Due date: 23 Oct, 202523 Oct, 2025 25.91 Lacs
Tender For corrigendum : rate contract for repairing and testing of different types of electronics cards of rc feeders, ewli, flame scanner, actuators, maxdna dcs system, dc chargers, tsi and vms system installed at 210 mw atps mppgcl chachai

State Government

CTN :41967782 Due date: 24 Oct, 202524 Oct, 2025 NA
Tender For corrigendum : tggenco-ktps vii stage/paloncha - supply of flame scanner head assembly,power supply module and asld spares

corporations/Associations/Others

CTN :41917139 Due date: 29 Oct, 202529 Oct, 2025 69.70 Crore
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cms (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014., suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye. colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as p

State Government

CTN :41235842 Due date: 21 Oct, 202521 Oct, 2025 25.0 Thousand
Tender For corrigendum : supply of secat-2 variable frequency flame scanner test kit
 Loading, Please wait...

Connect us via What's Up