Web Analytics Made Easy - StatCounter

Surge Suppressor Tenders

Get complete information related to latest Surge Suppressor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Surge Suppressor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Surge Suppressor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41531106 Due date: 26 Aug, 202526 Aug, 2025 NA
Tender For supply of contactor(with diode), current rating: 16 a, voltage rating: 415 v, main pole: 3 no, aux. contact: 1nc, control voltage: 77-143 v dc with surge suppressor as per drg.no. n/a specn: rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0) and is::8828-1996

Central Government/Public Sector

CTN :41282870 Due date: 28 Aug, 202528 Aug, 2025 69.9 Thousand
Tender For corrigendum : supply of rj-45 based surge suppressor (q3) , low voltage surge protective devices (surge protector panel) as per is 8794, is 12987 (q3)

Central Government / Public Sector

CTN :41514615 Due date: 01 Sep, 202501 Sep, 2025 NA
Tender For supply of contactor k-44 for 60 kva transformer, rated current: 95 amps, rated voltage: 690v ac, main pole: 4, aux contact 1 no + 1 nc, control voltage: 230v ac (168-300v ac means 230v +/- 30%) with surge suppressor as per rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1) and as per updated bom items issued by rdso lr.no el/7.1.108/mssbc, dated 19.09.2021 to abb model no: af 116 b-40, schneider model no.lc1d1150046m5 + la4da2u only accepted.

Central Government/Public Sector

CTN :41246201 Due date: 03 Sep, 202503 Sep, 2025 NA
Tender For corrigendum : feeders - 1 & 2 and bus coupler power contactors, 3 pole, 1000v ac, 50hz, suitable for 500 kva, 750v ac on load switching under ac-6a categ ory at temperature of 70 degree celsius & coil voltage of 110v +25% -30% dc with surge suppressor, 2no+2nc. as per rdso spec. no. rdso/pe/spec/tl/01 95-2019 (rev.-0) or latest for switch board cabinet of hog complaint lslrd coaches.accepted makes & models as per s.no.2 of bom of rdso specification m entioned in the above description are mentioned below :i) af1250-30-11 of abb, ii) mvo 820 of l&t,iii) 3rt12766av36-8ka0 of siemens (vide jdse (tl-ac sy stem design) / rdso lr. no. el/7.1.108/sbc/lslrd dt.08.11.23 attached for this modified model number) oem test certificate shall be submitted at the time of supply. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :41483296 Due date: 11 Sep, 202511 Sep, 2025 NA
Tender For supply of 200a 4 pole power contractor for 750 v ac as well as 415v ac with coil voltage 415v ac type cal 16-11a with surge suppressor similar to abb model-ek 110 with aux contract 2 no +2nc type cal, 16-11a as per bom edts 103rev d

Central Government/Public Sector

CTN :41423260 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For supply of contactor 32 amps (with diode), rated current: 32 amp.(at rated voltage & ac-3 utilization category) rated voltage : 690v, main pole: 3no, auxiliry contact 1 nc control voltage: 110v dc +/- 15% with surge suppressor for compressor unit cp 1.1, cp 1.2, cp 2.2 confirming to rdso spec no. rdso/pe/spec/0192-2018 (rev-1) or latest, make: abb, l&t, schneider, siemensnote:- material shall proccure from oem or his authorized dealers or supplier should submit valid authorization from oem

Central Government/Public Sector

CTN :41423266 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For supply of contactor (with diode), rated current 16 amp, rated voltage 690 v ac, main pole 3 no, aux, contact 1 nc, control voltage 77-143 v dc, with surge suppressor, as, per rdso specification no., rdso/pe/spec/ac/0184-2015 (rev.1) suitable for ventilation fan, condenser & heater of rmpu of lhb eog ac, coaches

Central Government/Public Sector

CTN :41400893 Due date: 25 Aug, 202525 Aug, 2025 NA
Tender For supply of power contactor (with diode) for compressor unit cp 1.1, cp 1.2, cp 2.1 & cp 2.2 rated current: 32 ampere (at rated voltage & ac 3 utilization category) rated voltage 690v, main pole: 3 no aux. contact: 1 nc, control voltage: 110 v dc +/- 15% with surge suppressor conforming to rdso specs no. rdso/pe/spec/ac/0184-2015(rev -1)

Central Government / Public Sector

CTN :41368416 Due date: 20 Aug, 202520 Aug, 2025 NA
Tender For corrigendum : supply of contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degree c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev 1) and asper update of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt. 17/09/21 to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22, abb catalogue no. af190b-40-22 and l&t cat. no. mcx 34 only acceptable. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :41401216 Due date: 01 Sep, 202501 Sep, 2025 NA
Tender For supply of surge suppressor 1.5k 120ca for woodward [surge suppressor 1.5k 120ca for woodward governor to ww part no. 16821073.]
 Loading, Please wait...

Connect us via What's Up