Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperatureindicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for repairing and calibration of temperatureindicators installed on boiler , work of repairing, calibration and rewiring of superheated wash water temperature control system , laying of comprehensive cable, installation of thermocouple and commissioning of indicators at the boiler station , work of repairing, rewiring, overhauling and commissioning of d- superheating system of exhaust line , repairing and commissioning work of temperatureindicators of sulfur furnace , laying of compressive cables of sulfur furnace, installation of sensors and commissioning of temperatureindicators , to carry out installation and commissioning work for raw-sulfated juice, clear juice, exhaust steam and injection water inlet temperature , over hauling, rewiring and recommissioning of auto drum water level control system of boilers , rewiring and recommissioning of high or low alarm system on boilers for water level , overhauling, rewiring and recommissioning of boiler steam generation system , overhauling, rewiring and recommissioning of boiler feed water measurement system
Tender For corrigendum : supply of equipment for logistics department - paper tearing test measuring range 0 to 1000 mn capacity resolution 0.1 mn indication error 1 % tearing arm 104 1 mm tearing angle 27.5 0.5 tearing distance 43 0.5 mm, paper puncture testing machine energy range of weights - 6, 12, 24 joule per meter accuracy - 2% within full range release angle of pendulum - 90 display - led (digital) 7 segment power - 220v, 50hz,single phase highlights: sample holder - 1 pendulum release mechanism -manual material -mild steel finish - powder coated havel gray & gray combination finish and bright chrome/zinc plating for corrosion resistant finish, weighing machine max capacity (max) maximum load the scale can measure. (3 kg ), min capacity (min) minimum load required for accurate measurement. (0.25 kg), 0.1 g 1 g resolution, sling psychrometer, bursting strength tester capacity: commonly 0 40 kg/cm . accuracy: +or -1 % of the full range (often within 10% to 90% of capacity). resolution: 0.1 kg/cm . operation: microprocessor-based, digital display (lcd/led) with peak hold test fluid: glycerin (approx. 98% purified). power requirement: 220v, single phase, 50 hz. memory. clamping: pneumatic or manual, often with 1/4 hp motor. fluid displacement rate: 95 + or 5 cc/minute., digital micrometer (0-25mm with least count 0.0010) (0 25 mm, 0.001 mm), digital vernier caliper (0-150mm)
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperatureindicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]
Tender For supply of equipment for the l/t department under tansche - equipment for the l/t department under tansche, sling psychrometer, digital micrometer(0-25mm with least count 0.001, digital vernier caliper (0 -150mm), weighing machine, bursting strength tester, paper tearing tester, paper puncture testing machine, lamination machine-thermal, tear resistance tester
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperatureindicators will be provided as per clause 20.2 of is 1180 (part 1). terminal agreement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is to beprovided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras corrigendum : supply of precision aneroid barometer complete with accessories model 103pm or 103 cr or equivalent , dry bulb thermometers mercury complete with accessories , wet bulb thermometers mercury complete with accessories , aneroid barometer complete with accessories , whirling psychrometer complete with accessories , mobile met kit model kestrel 5500 or equivalent , hand held anemometer complete with accessories , digital barometer reference complete with accessories , marine bucket with sea thermometer complete with accessories , empty cylinder for hydrogen gas 50kgs , technical documentation as per sotr