Tender For tender for establishment of centre of excellence in electrical vehicle power train technologies at vtu regional centre, bengaluru - servo motor rotating arm e, propeller fin e, battery connector e, jumper pin header e, battery holder e, usb cable e, button cap (large)passive elements, button(small) passive elements, button(large)passive elements, potentiometer(10ko)passive elements, switchpassive elements, capacitor(10uf)passive elements, capacitor(104)passive elements, resistor(10ko)passive elements, resistor(1ko)passive elements, resistor(220o)passive elements, big blue led active elements e, big yellow led active elements e, big green led active elements e, big red led active elements e, rgb led active elements e, active elements 1n4001 diode, active elements 1n4148 diode, pnp transistor(8550) active elements, npn transistor(8050) active elements e, relay active elements e, active buzzer active elements ev, motor driver e, seven segment display e, lcd display e, dc motor e, servo motor e, jumper wires e, tx/rx module e, tilt sensor e, ultrasonic sensor holder e, light sensor e, ultrasonic proximity sensors e, analog temparature sensors e, breadboards e, uno board e, usb cable for stm32 board e, ecu board, stm32 discovery board e, battery cell making machine, integrated electronics workstation, pcb design equipment, dynamometer 2w, electrical vehicle motors and drives workbench, battery management system (bms) training module e, model-based development (mbd) real-time controller, power electronics training bench, off board charger control board, pe-pp control panels, pdi unit, dc converters, drive axles, wheel axles, foot throttle e, auxiliary battery, relay e, harness, wheels e, differential e, moter ev, bms e, vcu e, mcu e, on board charger, battery pack e, naked chassis, belt pulley e, female type 6 charging socket e, front wheel axle ev, front wheel rim ( 12 inch) e, tubeless tyres e, main stand ev, side stand ev, mid - drive chassis e, switches ignition, horn, indicator, head light ev, cone-set ev, handle bar ev, t-stamp ev, fork ev, smart charger can ev, dc dc converter ev, swing arm ev, vcu ev, brake sensors ev, display ev, wiring harness ev, throttle (re twistable) ev, mid drive motor 3kw and pull belt e, mcu 120a e, battery 4kw nmc ev, cordless drill machine tools ev, tool kit trolley tools e, pipe wrench tools e, screwdriver 803 tools e, taparia screw driver 863 200 tools ev, taparia philips s/d psc862250 tools ev, taparia screw driver 861 100 tools e, installation tape tools ev, soldering gun tools e, multimeter tools e, hammer - 40mm nylon tools ev, hammer - 500g tools ev, chissel tools ev, tools 24pc socket set box, long circlip plier outer tools ev, long circlip plier inner tools ev, t spanner 14mm tools ev, t spanner 12mm tools ev, t spanner 10mm tools e, t spanner 8mm tools ev, t spanner 7mm tools ev, connector - 902 tools ev, tester tools ev, nose plier tools ev, monkey plier tools e, wise grip plier tools e, cutting plier tools e, wire cutter tools e, screw driver 2 in 1 - 903ibt tools ev, ring spanner set tools ev, double end spanner set tools ev, t allen key 3,4,5,6 mm tools ev, l allen key set tools ev, motor hall phase tester ev, continuity tester ev, safety helmet, programmable mcu, clamp meter ev, taco meter ev, mid drive mcu, hub motor mcu, hall sensor ev, mid drive stator, hub drive stator, induction stator, bldc stator, mid drive rotor, hub drive rotor, induction rotor, bldc rotor, induction motor, brush motor, shaft drive motor ev, bldc motor, pmsm motor, ev 4w - car, ev 3w - auto ev, ev2w - shaft drive - full vehicle, ev 2w - hub drive full vehicle ev, ev 2w - mid drive - full vehicle ev, ev 2w - hub drive - full vehicle ev, ev 2w - mid drive - full vehicle, ev 2w - hub drive - full vehicle, eight channel 3 amps cdc cell grading machine, cells bolt, cell 3.2 v 100ah lfp, hot air blower ev, green 100mm insulation, clamp meter 0-600 amps, battery tester, bus bars, screw gauge ev, silicon black, bla
Tender For supply of lauritz knudsen (formerly l & t) make switchgear spares for chp elect- fuel section at gsecl ukai tps. (chp maintenance (electrical)-et-6304) - l&t make 3 pole power contactor, type- ml-2, ac-3, 32 a, 415 v ac, l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make,3pole power contactor ml-6,coil voltage 110vac, ac-3 rating 110a cat.no. ss90921, l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, l&t make 3 phase power contactor type mnx 25 ac-3 rating 25a,cat.no.cs94110, l&t make 3 phase power contactor type mnx32 ac-3 rating 32a,coil voltage 110v ac,cat.no.cs94111aooo, power contactor mnx 40 coil:110vac cat no.:-cs94190 make:-l&t, l&t make 3 phase power contactor type mnx110 ac-3 rating 110a,coil voltage 240v ac,cat.no.cs94137, l&t make power cantactor type- mnx 300 with 2 no + 2 nc aux. contact, coil voltage 110 volt ac, ac-3 rating 300 amp., cat. no. cs 90280., l&t make,3pole power contactor in open execution type mn-400 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 400 * cat.no.ss 94043, l&t make 415v switch gear (acb), contactor kit ml-2 ss 95307, l&t make contact kits with out coil for contactor type:- ml 4, cat.no - ss 91257, spares kit without coil for contactor ml6, cat. no. ss 95313, make - l & t, l&t make spare kit without coil for ml-10 cat no ss 95315, l&t make 415v switch gear (acb), l&t make spare kit without coil for ml-12,cat no.ss 91127,l&t make 415v switch gear (acb), spare contact kit for l&t make mnx 110 power contactor cat no cs94154, spare contact kit for l&t make mnx 400 power contactor cat no cs94161, coil for l&t make power contactor. ml-8/10/12 ss91011, 220vac,/110vac, l&t make spare coil for mnx 400, coil voltage 110 vac, cat no cs94195, l&t make fornt mounting add-on block 2no + 2nc cat. no.cs94114 for mnx 9a to 40a contactor, l&t make, mnx type front mounting add on aux. contact block 1 no + 1 nc, cat no cs94118, l&t make, mnx type front mounting add on aux. contact block 3 no + 1 nc, cat no cs94113, l&t make control , contractor type mm01 with 4 ho +4hc contact , coil voiltage 110 vac cat no. ss 92014, l&t make 415v switch gear (acb), l&t make control contactor, type mm01 ac with 5 no +3nc contact , coil voiltage 110 vac, cat no. ss 92014, l&t make 415v switch gear (acb), l&t make dc control mx mini mx 09 1nc cat no cs94024, l&t make bi metal o/l relay for ml -2 range 9.0-14a , cat no ss 9185900ao, l&t make 415v switch gear (acb), l&t bimetal thermaloverloadrelay with single phasing protection.mn-2 9.0-15.0a ss94142, l&t make ml type,thermaloverloadrelay, range 20-32amp,direct mounting on ml 2/3 contactors,cat no-ss91859ooeo, bimetallic relay with single phasing protection, range: 66-110a, make: l&t, cat. no.-cs9422700k0, l&t make bimetal thermaloverloadrelay with single phasing protection, mn 12 type, cat.no. - ss94138oomo, relay range 3 - 5 amp operation, ct operated in combution with 90 - 150 amp (ct operated) seprate mounting., l&t make b/m o/l relay,mn-12 l type,range-180-300a,cat no-ss 94127 ooqo, l&t make bimetal (th) overloadrelays ( with single phasing protection) thermal o / l relaytypemn 2cat.no.ss 9412700 porelay range3 - 5 ampoperationct operatedin combution with 90 - 150 amp ct mounted on ct, switch disconnector fuse unit tpn 32a 415v make:-l&t type:-fn, l&t make switch disconnector (415 volt, 50 hz) fuse units type: fn 63 tpn, cat.no.: sk 95421, capacity:- 63 amp, ac, 23 amp, no of poles: 3 + n link, l&t make switch disconnector-fuse, type-fn 125, 125amp, tpn+fuse links, cat no- sk 95001., l and t make switch disconnector isolator, type fn 250 tpn, cat. no. sk95683., landt make switch disconnector-fuse, type-fn400, 400amp, tpn, cat no
Tender For time delay module for time relay vcb (pos no.136.3) as per para no.8 of scope of supply of clw specn.no. clw/es/3/0064 alt-c or latest. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of intelligent analog addressable smoke detector complete with mounting base complete as required , addressable manual call point complete as required , addressable fire control module relay module as required , one time rectification and restoration of the fire alarm system , micro processor based intelligent addressable main fire alarm panel , one time replacement and rectification of the fire alarm system , supply laying and termination of 2cx1 5 sq mm frls pvc insulated copper conductor , supply and installation of loop powered base addressable sounders complete with all fixing materials complete as required , one time rectification of the fire alarm system 2 loop which is having 153 nos of detectors and 10 manual call points
Tender For corrigendum : cting for and on behalf of the president of india invites e-tenders against tender no j-sg-ot-12-2026-662346 closing date/time 03/07/2026 15:00 hrs. bidders will be able to submit their original/revised bids upto closingdate and time only. manual o ers are not allowed against this tender, and any such manual o er received shall beignored.1. nit headername of workaugmentation of block working arrangements by provision of solid state blockinstruments in lieu of existing fm block instruments in poy-cnv and vnb-nilsingle line block sections of palakkad division, along with associated eialterations and other signalling works at poy and cnv stations.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime03/07/2026 15:00date time of uploadingtender11/06/2026 18:42pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 14469883.92tendering section signalpgtbidding style[ decision at schedulelevel ]bidding unitearnest money (rs.) 289400.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 12 monthscontract type works - general contract category expenditurebidding start date 19/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-sor items1276856.85above/below/par1021330 140.00 per unit 285.86 40020.40 44.04 57645.38description:- wiring of relay inputs to wago block and wago block to datalogger. necessarywagos required is included as per schedule2021340 20.00numbers 285.86 5717.20 44.04 8235.05description:- wiring of analog voltages from ips room to datalogger. necessary wagos required isincluded as per schedule3031040 4.00numbers28118.51 112474.04 44.04 162007.61description:- supply and provision of earthing as per rdso speci cation rdso/spn/197/2008 orlatest (as per technical specification enclosed)4051160 1000.00 metre 301.05 301050.00 44.04 433632.42description:- supply of underground jelly lled 6 quad, 0.9mm dia as per spec irs:tc 30-05 withamd 5 or latest5051300 4.00numbers3962.00 15848.00 44.04 22827.46description:- supply and xing of 20 pair krone module housed in ms box and termination optical fiber cableables6051320 4.00numbers4761.16 19044.64 44.04 27431.90description:- supply and fixing of 20 pair ct box and termination of cables7051410 20.00numbers 262.65 5253.00 44.04 7566.42description:- supply of rcc cable markers (supply of rcc cable markers as per drawingno.cste/cn/ofc/1. the lettering on the cable marker shall be "sig" / "tele" / "ofc" as per theinstructions of railway representative at site.) as per drawing enclosed8051440 500.00 metre 64.10 32050.00 44.04 46164.82page 1 of 9run date/time: 11/06/2026 18:43:47palakkad division-s and t/southern rlytender documenttender no: j-sg-ot-12-2026-662346closing date/time: 03/07/2026 15:008description:- excavation of cable trench in all kinds of soil except hard rocky areas includingclearing of roots of trees, rocks, bushes etc. to a depth of 1.0 mtrs and to a width of 0.3 mtrs. (layingof cables is not included in this schedule)9051490 150.00 metre 314.41 47161.50 44.04 67931.42description:- removing/breaking of existing rcc slabs on the passenger platform, trenching to adepth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cablesare laid and replastering with cement mortar, re lling the trench by ramming and consolidating it asper the instructions of railway representatives at site. (laying of cables is not included in thisschedule).10051520 36.00 metre 385.45 13876.20 44.04 19987.28description:- excavation of trench to a depth of 1 mtr. for track crossing of cables, re lling oftrench by ramming and consolidating it as per the instructions of railway representative at site afterlaying of dwc/rcc
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relaythermaloverload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermaloverloadrelay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relaythermaloverload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overloadrelay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermaloverloadrelay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relaythermaloverload direct mounting relay setting range 5.5-8a ref tr2-d09312, relaythermaloverload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermaloverloadrelay direct mounting ralay setting range 1-1.6a, relaythermaloverload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relaythermaloverload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For multifunction timer relay 24vdc, 8a, type of module : timer, counting range : 0,1s...100h, kind of output : spdt, output 1 electrical parameters : 250v ac / 8a, manufacturer series : mur 1, number of operation modes : 10, counter operation modes : delayed switching on, on and off delay, on for the set interval, pulse after a specified time, symmetrical cycle operation pulse first, with the control contact s, electrical connection : screw terminals, mounting : for din rail mounting, operating temperature : -20...60 c, number of pins : 6, ip rating : ip20, supply voltage: 24...240v ac, 24...240v dc, note: crouzet mur1 or similar as per specification. ]
Tender For supply of supply of 6 a sp mcb , supply of 10 a sp mcb , supply of 16 a sp mcb , supply of 20 a sp mcb , supply of 25 a sp mcb , supply of 32 a sp mcb , supply of 20 a dp mcb , supply of 20 a tp mcb , supply of 40 a fp mcb , supply of 63 a fp mcb , supply of 125a four pole fp mccb , supply of 200a four-pole fp mccb , supply of 40 a, double pole, rccb , supply of 63 a four pole mccb , supply of four pole, ac1 rating 40a , contactor , supply of three pole ac3, 32a rating contactor , supply of under current monitoring relay , supply of 3-pole power contactor with add on block , supply of thermaloverloadrelay , supply of rotary operating direct handle for mccb , supply of rotary operating extended handle for mccb , supply of 06 way double door db , supply of weather proof frp junction box , supply of copper flexible cable 2c x 1.5 sq.mm , supply of copper flexible cable 3c x 1.5 sq.mm , supply of copper flexible cable 3c x 2.5 sq.mm , supply of 4 c x 10 sq.mm xlpe armoured aluminium cable , supply of frlsh single core copper conductor 1.5 sqmm , supply of frlsh single core copper conductor 2.5 sqmm , supply of frlsh single core copper conductor 4 sqmm , supply of frlsh single core copper conductor 6 sqmm , supply of heat shrink straight through joint kit for 3.5 core 95 sqmm , supply of 4 feet, 20w energy efficient led batten light fitting , supply of 9w led bulb with b22 base , supply of 20w led bulb with b22 base , supply of square type 36 w led down light , supply of 50 w led fllod light , supply of 70 w led street light , supply of 1200 mm sweep five star rated bldc fan , supply of 150 mm sweep exhaust fan , supply of 400mm sweep pedestal fan , supply of 300mm sweep wall fan , supply of 300 mm sweep table top type rechargeable fan , supply of 5 or 6 amp, 3 pin plug top , supply of 15 or 16 amp, 3 pin plug top , supply of automatic programmable analog time switch , supply of 3 phase digital multifunction meter , supply of flush-mounted analog panel type ammeter , supply of flush-mounted analog panel type voltmeter , supply of panel mounting red pilot light , supply of panel mounting green pilot light , supply of panel mounting yellow pilot light , supply of panel mountingf blue pilot light , supply of panel mounting amber pilot light , supply of connector din rail mounted for 2.5 sq. mm conductors , supply of connector din rail mounted for 25 sq. mm conductors , supply of mild steel din rail 1 mtr length , supply of 20w, 4 feet led tube light , supply of surface mountable, 15w led emergency lamp , supply of 1hp centrifugal pump single phase , supply of digital vernier caliper , supply of addressable photoelectric smoke detector for fire alarm system , supply of addressable zone interface module , supply of audio visual alarm device for addressable fire alarm system , supply of manual call point mcp for addressable fire alarm system , supply of 2 core 1.5 sqmm red fire alarm cable //bid details 2 / 53
Tender For supply of "ux. protection relay q-118 with jss/mil gr.electronics components timer and other requirement as per clw spec .no. clw/es/r-27, alt-z sr.no.1 of sheet-13/a off time delay relay type ct32.1/110v dc for q-118 application consisting of timing module ct32/dc110v r- 1 no., plug in relay c31w/dc110v s - 1 no., system socket s3m0 - no.,with base and mounting arrangement only as per clw specification no. clw/es/r-27z." [ warranty period: 30 months after the date of delivery ] ]