Tender For supply of proximity switch, plasser part no. el-t1422/k/u sub. el-t1422/k/u-st, make: plasser/turck/siemens/soyuz, specifications: 10-65vdc; current rating-200ma; sensing distance 8 to 10mm; contacts1-positive, 2-nc, 3-negative, 4-no. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For 5hp non clog submersible sewage pump set, pumping capacity 72 cubic meter per hour at 8 mtrs head with speed 1450 rpm, complete with water protected seal for continuous operating 415v, 50 hz, supply with 10 mtrs, resin filled control cable and 10mtrs s.s chain with shackle and suitable fully automatic three phase starter control panel( dol/star delta starter which is suitable for that pump) along with single phase preventer with phase reversal sensing and dry run relay protection (current sensing type), thermistor relay and moisture control relay, analog /digital voltmeter , analog /digital ammeter , power on/trip and indication lamps, on/off switch and auto/manual mode switch (authorized dealership certificate to be enclosed while submitting offer, test certificate and warranty certificate to be submitted along with supply). make: ksb, kirloskar, mbh. karvel or similar [ warranty period: 30 months after the date of delivery] ]
Tender For supply of pressure sensing device having rated impulse withstand voltage (ump) - 4000v & rated operational current ac - 15:230v-2a, dc-13:24v-2a, 110v-0.25a, 24v ac-dc-0.1a along withfixing bracket, as per eaton pt.no. mcs 11-g + s3-mcs,conforming to iec60947-5-1., make : eaton or equivalent, having same fitment and functional compatibility. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of lauritz knudsen (formerly l & t) make switchgear spares for chp elect- fuel section at gsecl ukai tps. (chp maintenance (electrical)-et-6304) - l&t make 3 pole power contactor, type- ml-2, ac-3, 32 a, 415 v ac, l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make,3pole power contactor ml-6,coil voltage 110vac, ac-3 rating 110a cat.no. ss90921, l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, l&t make 3 phase power contactor type mnx 25 ac-3 rating 25a,cat.no.cs94110, l&t make 3 phase power contactor type mnx32 ac-3 rating 32a,coil voltage 110v ac,cat.no.cs94111aooo, power contactor mnx 40 coil:110vac cat no.:-cs94190 make:-l&t, l&t make 3 phase power contactor type mnx110 ac-3 rating 110a,coil voltage 240v ac,cat.no.cs94137, l&t make power cantactor type- mnx 300 with 2 no + 2 nc aux. contact, coil voltage 110 volt ac, ac-3 rating 300 amp., cat. no. cs 90280., l&t make,3pole power contactor in open execution type mn-400 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 400 * cat.no.ss 94043, l&t make 415v switch gear (acb), contactor kit ml-2 ss 95307, l&t make contact kits with out coil for contactor type:- ml 4, cat.no - ss 91257, spares kit without coil for contactor ml6, cat. no. ss 95313, make - l & t, l&t make spare kit without coil for ml-10 cat no ss 95315, l&t make 415v switch gear (acb), l&t make spare kit without coil for ml-12,cat no.ss 91127,l&t make 415v switch gear (acb), spare contact kit for l&t make mnx 110 power contactor cat no cs94154, spare contact kit for l&t make mnx 400 power contactor cat no cs94161, coil for l&t make power contactor. ml-8/10/12 ss91011, 220vac,/110vac, l&t make spare coil for mnx 400, coil voltage 110 vac, cat no cs94195, l&t make fornt mounting add-on block 2no + 2nc cat. no.cs94114 for mnx 9a to 40a contactor, l&t make, mnx type front mounting add on aux. contact block 1 no + 1 nc, cat no cs94118, l&t make, mnx type front mounting add on aux. contact block 3 no + 1 nc, cat no cs94113, l&t make control , contractor type mm01 with 4 ho +4hc contact , coil voiltage 110 vac cat no. ss 92014, l&t make 415v switch gear (acb), l&t make control contactor, type mm01 ac with 5 no +3nc contact , coil voiltage 110 vac, cat no. ss 92014, l&t make 415v switch gear (acb), l&t make dc control mx mini mx 09 1nc cat no cs94024, l&t make bi metal o/l relay for ml -2 range 9.0-14a , cat no ss 9185900ao, l&t make 415v switch gear (acb), l&t bimetal thermaloverloadrelay with single phasing protection.mn-2 9.0-15.0a ss94142, l&t make ml type,thermaloverloadrelay, range 20-32amp,direct mounting on ml 2/3 contactors,cat no-ss91859ooeo, bimetallic relay with single phasing protection, range: 66-110a, make: l&t, cat. no.-cs9422700k0, l&t make bimetal thermaloverloadrelay with single phasing protection, mn 12 type, cat.no. - ss94138oomo, relay range 3 - 5 amp operation, ct operated in combution with 90 - 150 amp (ct operated) seprate mounting., l&t make b/m o/l relay,mn-12 l type,range-180-300a,cat no-ss 94127 ooqo, l&t make bimetal (th) overloadrelays ( with single phasing protection) thermal o / l relaytypemn 2cat.no.ss 9412700 porelay range3 - 5 ampoperationct operatedin combution with 90 - 150 amp ct mounted on ct, switch disconnector fuse unit tpn 32a 415v make:-l&t type:-fn, l&t make switch disconnector (415 volt, 50 hz) fuse units type: fn 63 tpn, cat.no.: sk 95421, capacity:- 63 amp, ac, 23 amp, no of poles: 3 + n link, l&t make switch disconnector-fuse, type-fn 125, 125amp, tpn+fuse links, cat no- sk 95001., l and t make switch disconnector isolator, type fn 250 tpn, cat. no. sk95683., landt make switch disconnector-fuse, type-fn400, 400amp, tpn, cat no
Tender For supply of proximity switch, plasser part no. el-t1422/k/u sub. el-t1422/k/u-st, make: plasser/turck/siemens/soyuz, specifications: 10-65vdc; current rating-200ma; sensing distance 8 to 10mm; contacts1-positive, 2-nc, 3-negative, 4-no. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relaythermaloverload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermaloverloadrelay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relaythermaloverload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overloadrelay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermaloverloadrelay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relaythermaloverload direct mounting relay setting range 5.5-8a ref tr2-d09312, relaythermaloverload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermaloverloadrelay direct mounting ralay setting range 1-1.6a, relaythermaloverload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relaythermaloverload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For corrigendum : tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , loadover voltage circuit of solid state sensing type for alarm indication and pfc , loadover voltage circuit of solid state sensing type for alarm indication and pfc , loadover voltage circuit of solid state sensing type for pfc and tri
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin