Get complete information related to latest Transformer Centre Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Centre Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Centre Tenders.
Tender For corrigendum : work of erection and maintenance ofoverhead ht line,lt line with bare new conductor or abc and transformercentre inemegency situation under pardi urban sdn under vapi rural division
Tender For supply of set of tap changer spares consisting of 02 items, 1) contact roller housing to repl part no: s1513, drawing no: am-300009-p1 or aal part no: g1513, drawing no: 9919000080001 - qty- 01 no / set. 2) roller housing to repl part no: s1516, drawing no: ag-416382-p1 or aal part no: g1516, drawing no: 9910383533001 - qty - 01 no / set. make : river engineering (or) anantashree engineer only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese
Tender For work of erection of 200kva pole mounted distribution transformercentre alongwith associated overhead 11kv s/c line and conversion of 1ph 4w, for improvement of low voltage near peace valley, sirvoi-quepem,under the jurisdiction of elect.sub div-ii,
Tender For providing additional 10men (4no.s skilled, 6no.s unskilled) and one ladder mounted vehicle including driver (mahindra pick-up van or equivalent any other vehicle) with cabin for transporting men and separate carrier for transporting for rendering 24x7 service and also for carrying out line maintenance and major breakdown works on 11kv & lt distribution system and distribution transformercentres in the jurisdiction of o&m sub division, hescom., khanapur and any other area and work assigned by the engineer in charge of section or sub division office of o&m sub division, hescom., khanapur along with t & p articles, mobile phone and protective devices on contract basis for period of one year and further extendable for another year