Get complete information related to latest Transformer Centre Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Centre Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Centre Tenders.
Tender For tender for the work of replacement of deteriorated poles and material of 200kva dhawaskarwada transformercentre , at dhawaskarwada, karapur in the jurdisction of s.o karapur under s.d.ii( r),sankhalim,sankhali.goa
Tender For erection of ht, lt line & transformercentre of o/h line conductor with abc, dismantling of pole & transformer center, maintenance of old line & other miscellaneous work under various scheme on annual rate contract basis for any scheme for simada sub division or any sub division under surat rural division.
Tender For corrigendum : rectification of electrical safety defects - supply and installation of electrical danger notice boards conforming to is 2551 1982 and the indian electricity rules, 1956. each board shall be fabricated from mild steel plate not less than 1.6 mm thick, vitreous-enamelled in visible red finish, with lettering, figures, and skull-and-crossbones emblem in signal white. plate size 200 150 mm with rounded corners, suitable for 415 v medium-voltage installations, bearing bilingual wording (english and tamil) centrally spaced as per the standard. fixing holes of suitable diameter for rivets shall be provided at the corners. boards shall be permanently affixed in conspicuous positions on distribution boards and panels using corrosion-resistant rivets or equivalent fasteners. the rate shall be quoted per piece inclusive of supply of board, rivets, and complete affixing, inspection, testing, cleaning, recommissioning, and submission of the test report for the lightning protection system installed on a 30 metre-high ms wireless tower, including the removal and replacement of all associated fasteners on the downcomer gi plate, ensuring full compliance with applicable standards and operational safety requirements. , inspection and testing of earth electrodes; reconditioning and refilling of earth pits; removal of corrosion from contact plates; replacement of fasteners; cleaning of earth pit troughs; correction of wall separators for earth pits; painting with yellow colour; fixing of durable identification labels with red-coloured text in the respective troughs; provision of closure slabs; and submission of test reports along with photographic evidence. walls to be provided newly: 5- earth pits with existing walls: 22, refilling of silica gel in 11 kv/415 v step-down transformer breather, ensuring proper colour indication and complete replacement of exhausted, dehydrated, or saturated silica gel., insulation and safety covering of exposed live terminals in the 125 kva dg set and of the outer surface of the tneb ht meter box using pvc/acrylic insulation sheets of adequate thickness, rating, and appropriate size suitable for the respective voltage levels, ensuring full electrical insulation and compliance with safety standards. size; 30x20 inches-1 no. 12x24 inches-1 no.
Tender For corrigendum : work of erection and maintenance ofoverhead ht line,lt line with bare new conductor or abc and transformercentre inemegency situation under pardi urban sdn under vapi rural division
Tender For supply of 9 kva, 750/415/190v ac 3-phase star star star step down distribution transformer for as per rdso spec no. rdso/pe/spec/tl/0158-2010(rev1), type-1. as per drg.no. n/a specn: rdso/pe/spec/tl/0158-2010,rev-1,type-1
Tender For corrigendum : provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, power factor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & n
Tender For the work of erection of 200 kva distribution transformercentre at parsekarwada harmal along with renovation of existing lt lines under the jurisdiction of section office, mandrem, sub div-iii, agarwada, div.xvii, mapusa
Tender For power electronics lab equipments - power elctronics lab equipments, line synchronized ramp trigger circuit using ujt with ac load to measure firing angles kitujt relaxation oscillator circuit, provision to add dc pedestal voltage to the capacitor in the circuit, triggering circuit fo r2scrs using pulse transformer, measure the phase angle of load, 24v lamp ac load using 2scrs, builtin power supply, scr commutation circuit kit" provision to charge the capacitance which will be used for voltage commutation, built in power supplies , class a,b commutation circuits", single phase to single phase cyclo converter kit"cyclo converter with divide by 2 supply frequency and divide by 3 frequency, +ve and ve polarity zero crossing detectors using optocouplers, decade counters to generate required control signals, isolated 4nos. of dc power supplies to trigger the scrs, triggering circuits to trigger the power scrs, power circuit using center tapped transformer, power circuit using 4scrs and12v-0-12v power transformer and resistive load, built in power supply", pwm based step down dc chopper using mosfet/igbt kit"pwm ic controller-based step down chopper, output voltage vs dutycycle, load characteristics without feedback, load characteristics with feedback, output voltage vs input voltage with feedback, built in power supply", single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kitsinglepulse 50 hz clock generation, variable duty cycle generation on both half cycles, h bridge power circuit using 4nos. of mosfets, 4nos. of individual power supply for gate trigger circuit, built in power supply, on / off control of lamp using solid state relay kit"input switch to control the lamp on/off using solid state relay, one ssr module to test with lamp load, builtin power supplies", speed control of ac motor using vfd drive"adjustable v/f curve and vector control, keypad and external control of ac motor, builtin modbus (rs-485) pc communication ,suitable for 2hp motor", lamp dimmer circuit using triac kit"variable ac power circuit using triac, diac circuit to trigger thetriac in both half cycles, provision to vary the charging time of capacitor, (changing the phase angle also)for the diac"