Web Analytics Made Easy - StatCounter

Transformer Foundation Tenders

Get complete information related to latest Transformer Foundation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Foundation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Foundation Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45489910 Due date: 24 Jun, 202624 Jun, 2026 19.20 Lacs
Tender For construction of transformer foundation for accommodating spare generator transformer in front of unit-3 transformer yard at btps.

State Government

CTN :45475935 Due date: 15 Jun, 202615 Jun, 2026 1.01 Crore
Tender For installing new 200mva, 220/110kv 3 ph trfr station in existing spare bay available at 220kv ss brahmapuram- civil works- construction of transformer foundation, at 220kv and 110kv bay, pump house for fire fighting system.

Central Government/Public Sector

CTN :45475154 Due date: 30 Jun, 202630 Jun, 2026 30.00 Lacs
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an

Central Government/Public Sector

CTN :45375193 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo

Central Government/Public Sector

CTN :45257517 Due date: 27 May, 202627 May, 2026 NA
Tender For civil works for station transformer foundation at gt area telengana

CTN :45061589 Due date: 07 May, 202607 May, 2026 2.66 Lacs
Tender For construction of temporary outdoor type rmu & transformer foundation at p shed substation at sewree

State Government

CTN :44944396 Due date: 27 Apr, 202627 Apr, 2026 4.91 Lacs
Tender For demolition and restoration of damaged existing rcc foundation of unit-ii , unit-iv including and repair/reconstruction of tail race side wall and bottom floor of unit no-1 at rongtong power house under cmd bhabanagar

CTN :44521324 Due date: 28 Apr, 202628 Apr, 2026 20.71 Lacs
Tender For corrigendum : providing galvanized steel sheet roofing and enclosure over transformer foundation at ipf sri vijayapuram civil works

CTN :44920389 Due date: 07 May, 202607 May, 2026 26.32 Lacs
Tender For corrigendum : augmentation of 3rd transformer foundation and allied civil works at 132 kv gss, ajasar, distt. jaisalmer

Central Government/Public Sector

CTN :44930842 Due date: 09 May, 202609 May, 2026 2.93 Crore
Tender For rfq 11955 for construction of foundation of banwas fan, electrical control room, mechanical room and transformer foundation
 Loading, Please wait...

Connect us via What's Up