Tender For transportation of 20/25 mva, 132/33 kv power transformer with oil drums and all accessories including rtcc panel loading 132 kv surajgarh (district jhunjhnu) to unloading at 132 kv gss chitawa on transformerfoundation
Tender For departmental estimate towards work a making of two no shed at ddu b making of one shed with foundation at golepahari c repairing of one no shed at dhori east pumping station d making of five no of coupling guard for used in different pump motor
Tender For erection of 4 inch dia pipe line for providing water to mobile crusher at new check post in favour of aadocm and work of pump foundation near new check post aadocm under aadocm dhori area
Tender For m&r to pwss at hingna, bhandara, kalmeshwar, gondia, umred... supply of spares for chlorinators & annual maintenance contract for chlorinators... - chlorinator, servicing and overhauling of job chlorinators for a period of one year including a) every month visit for periodical maintenance of chlorinators, checking them for proper functioning and routine checkup including minor consumables required. b) attending breakdown calls if any apart from the routine regular monthly visits., supply of spares for chlorinators and related piping system as under:-, (technical sanction no 137123secn for august2023 ) filter made from schedule 80, a106, grade b, carbon steel, (technical sanction no 137123secn for august2023 ) ejector body., (technical sanction no 137123secn for august2023 ) ejector diaphragm assembly, (technical sanction no 137123secn for august2023 ) needle valve, (technical sanction no 137123secn for august2023 ) actuator for diaphragm type pressuregauge, (technical sanction no 137123secn for august2023 ) inlet valve spring made of hastelloy, (technical sanction no 137123secn for august2023 ) vacuum regulator ptfe diaphragm assembly., ((technical sanction no 137123secn for august2023 ) nrv for vacuum tubing with suitable connectors.., (technical sanction no 137123secn for august2023 ) 3/8* 18g, pvc coated copper tube with stub enf and brass nut-6 feet long, (technical sanction no 137123secn for august2023 ) o ring set / gasket set, (technical sanction no 137123secn for august2023 ) ejector inlet adaptor & rotameter outlet adaptor with nut, (technical sanction no 137123secn for august2023 ) inlet and outlet piping set with fitting like unions, valves etc complete, (technical sanction no 137123secn for august2023 ) filter elbow and tee, (technical sanction no 137123secn for august2023 ) diaphragm type ss pressure gauge, (technical sanction no 137123secn for august2023 ) inlet water ss pressure gauge with tee and adaptor., (technical sanction no 137123secn for august2023 ) filter to regulator copper tube with stub end and brass nut, (technical sanction no 137123secn for august2023 ) borosilicate glass tube with teflon float., (technical sanction no 137123secn for august2023 ) inlet ventur, (technical sanction no 137123secn for august2023 ) outlet venturi, (technical sanction no 137123secn for august2023 ) inlet valve body, cap and pin., supply of yoke clamp & tonner key, providing , erecting & commissioning of chlorinetrap made of 100 mm dia seamless steel pipe with chlorine control valve with mounting plate & necessary hardware to mount on wall/frame with necessary copper pipe etc complete, providing, erecting, commissioning of new vacuum type floor mounted chlorinatorof 5 kg/hr capacity including-filter unit made ofschedule 80a 106 grade b carbon steel, -inlet copper tube with stub end and brass nut length 2 mtrs-filter vacuum copper tube with stub end & brass nut, inlet valve assembly having ptfe seat and hastelloy spring, -vacuum regulator with ptfe diaphragm assembly pvc front and back body,. rotameter made out of pvc with borosilicate tube teflon float and flow control valve spindle made of pvc, -pvc tubing with nuts form vacuum regulator to rotameter., ejector assembly containing ejector block of pvc venturiset nrv gas nrv water drain and inlet water gauge, -vacuum tubing, fiber board with angle set, chlorine pressure, inlet /outlet pipingwith isolation valves up to as required length withfoundation along with all required accessories complete, supplying, erecting, testing and commissioning ofminimum three & above star rated centrifugal water pump (monoblock), 415 v, threephase, 50 hz, a.c. supply of 3.75 kw/5 hp with discharge 715/200 lpm for head of 17/39 m and 65 mm suction/50 mm delivery pipe on provided cc foundation as per specification no. wp-cgp., supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary mater
Tender For to assist contractually, transportation of 1000gpm pump and construction of rcc foundation (including all building materials) in ug at w7 panel of bagdona seam at tawa mine of pathakhera area, wcl.
Tender For corrigendum : custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformerfoundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..
Tender For laying and fitting of 6inch m.s pipe line for installing of pump motor with foundation at 17-18l/1d of rana seam(r-v) at bhanora west block colliery under satgram-sripur area