Get complete information related to latest Transmission Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transmission Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transmission Pole Tenders.
Tender For execution of works with supply of materials for provision of 33 kv source feeder to serakuam ss by erecting of 33kv line to be tapped off from the existing 33kv moolakaraipatti palaniappapuram feeder from moolakaraipatti ss - fixing of 33kv ht disc with metal partserection of ht line with acsr 6/4.72 (dog) with 50% lc workalteration of clamperection of 33kv double pole dp structureerection of cradle guarding
Tender For work of construction of a new 11 kv feeder for bifurcation of overloaded 11 kv chakarpur feeder under edd khatima in capital s.i. head, including supply of decentralized materials, as per tender specification. - annexure-a (supply of following material as per upcl norms.), bracing clamp for sp-55 with nut and bolt., pp & clamp with nut and bolt st pole sp-55., stay clamp for sp-55 with nut and bolt., pp & clamp with n&b st pole sp-72., pp & clamp with n&b pcc pole, 8.5 mtr., stay clamp for pcc pole., ht stay insulator., 33 kv suspension ties on every pin insutlator., ipc with aluminium bail for earthing., 11 kv ipc for covered to covered cond., 11 kv ipc for covered to bare conductor., 11 kv mid span jointing kit., 11 kv aaac covered cond. al-59, 99 sq.mm., 11 kv tension clamp with bail & ipc., annexure-b (following work as per upcl norms), chemical earthing., fabrication of steel., excavation of pit for stay set., erection of 11 kv stay set,, grouting of stay set., excavation of pit for pole., erection of single pcc pole., erectin of single sp-55 pole., erection of single sp-72 pole., erection of pcc double pole., erection of sp-55 double pole., grouting of pole., muffing of pole., painting of sp-55 pole., lopping and choppong of tree branchases., cartage of pcc pole, 51-70 k, cartage of sp-55 pole, 51-70 km., cartage of sp-72 pole, 51-70 km., cartage of petty material, 51-70 km., headload cartage of pcc pole, 0-1 km., headload cartage of sp-55 pole, 0-1 km., headload cartage o sp-72 pole, 0-1 km., headload cartage of material, 0-1 km., fixing of 33 kv suspension ties., fixing of ipc with al, bail for earting., jumpering of d/p tpmo, fuse set and t/f., jumper section pole., fixing of 11 kv 90 kn tension clamp b&ipc., fixing of 11 kv ipc for cc to cc cond., fixing of 11 kv ipc for cc to bare cond., fixing of 11 kv mid span jointing kit., laying spreading, stringing aac conductor
Tender For providing of custom bid for services - construction of 11 kv/lt lines, establishment of double-pole lt substations, installation of metering systems, and the shifting of various ht/lt electricity lines in the area of edd, lalitpur under deposit scheme
Tender For rate contract for supply of materials and execution of various maintenance works, as and when required during emergency in electric division anantnag kpdcl for the fy year 2026-27 - supply, erection, testing & commissioning of s.t pole 11mtr. long sp-56 with base plate & cap for ht. strictly as per rec standards, erection, testing & commissioning of s.t pole 11mtr. long sp-56 including its carriage from divisisonal store to site, supply, erection, testing & commissioning of s.t pole 9mtr long sp-33 with base plate & cap for ht. strictly as per rec standards, erection, testing & commissioning of s.t pole 9mtr long sp-33 including its carriage from divisisonal store to site, supply, erection, testing & commissioning of s.t pole 8mtr long sp-15 with base plate & cap for lt. strictly as per rec standards, erection, testing & commissioning of s.t pole 8mtr long sp-15 including its carriage from divisisonal store to site, providing of hydraulic crane on hire basis for loading/unloading of dts of different capacities inclouding fuel and operator faling in the juridection of ed anantnag, erection, testing & commissioning of pcc pole 8mtr long including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 100mmsq (dog) conductor, laying, stringing, tensioning & binding of acsr 100mmsq (dog) conductor including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 50mmsq (rabbit) conductor, laying, stringing, tensioning & binding of acsr 50mmsq (rabbit) conductor including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 30mmsq (weasal) conductor, laying, stringing, tensioning & binding of acsr 30mmsq (weasal) conductor including its carriage from divisisonal store to site, providing & fixing of ismc 100x50x6mm channel iron cross arms for x-mer frame 9long @ 25.2 kg each -1 no including nuts & bolts, fixing of ismc 100x50x6mm channel iron cross arms for x-mer frame 9long @ 18.63 kg each -1 no including nuts & bolts, providing & fixing of ismc 75x40x6mm channel iron cross arms for x-mer frame- 1 nos @18.63 kg each 9 long including nuts & bolts, fixing of ismc 75x40x6mm channel iron cross arms for x-mer frame-, providing ,fixing, of ismc 75x40x6mm x-arm 5 long, fixing, of ismc 75x40x6mm x-arm 5 long-, providing ,fixing, of ms angle iron braces 50x50x6mm-4.5 ft long,, fixing, of ms angle iron braces 50x50x6mm-4.5 ft long, providing and fixing of sprial earthing made of 115 turns of gi wire swg no.8 placed 1.5m below ground level including excavation of pit, refilling the same withsoft soil, fixing of sprial earthing made of 115 turns of gi wire swg no.8 placed 1.5m below ground level including excavation of pit, refilling the same withsoft soil, supply,fixing, testing & commissioning of 11kv link set (polymer) station type as per is standards, fixing, testing & commissioning of 11kv link set station type (polymer/porcelain )as per is standards, supply,fixing, testing & commissioning of 11kv link set heavy duty as per is standards, fixing, testing & commissioning of 11kv link set heavy duty (polymer/porcelain ) as per is standards, supply,fixing, testing & commissioning of 11kv do fuse set (polymer )as per is standards, fixing, testing & commissioning of 11kv do fuse set (polymer/porcelain ) as per is standards, supply,fixing, testing & commissioning of 11kv la set (polymer )as per is standards, fixing, testing & commissioning of 11kv la set (polymer/porcelain ) as per is standards, providing and fixing of lt fuse set as approved by kpdcl., supply,fixing, testing & commissioning of 11kv disc set (polymer) 45 kn complete set, supply,fixing, testing & commissioning of 11kv disc set (porcelain) 45 kn complete set, fixing, testing & commissioning of 11kv disc set (polymer/po
Tender For requirement of material at sahlawas store - ht coupling link bolt with rubber bush for 50/60 cs vt pump (no. rb-228-252), ms nut & bolt 4/8x2.5 , pvc tape roll , pvc footvalve 5 with pvc nipple, pvc footvalve 6 with pvc nipple, ms bend 6 , old dhoti, rubber sheet 1/8 , green heliflex pipe 5 , pvc hose pipe 1 dia. (30 mtr), waterproof tarpaulin sheet 18*12, gi wire (wire dia. 3mm), pvc copper wire 6 sqmm single core, pvc copper wire 4 sqmm single core, pvc copper wire 2.5 sqmm single core, 8" dia rubber gasket (for ep set bend), ci nipple with flange 5 , ci nipple with flange 6 , ac contactor 3 pole na25n (bch), flat three core pvc insulated copper cable 6sqmm. (havells/polycab), rubber bush for 125 cs pump (size: id 102mm x od 120mm x l 150mm) as per sample., rubber bush for 150 cs pump (size: id 135mm x od 175mm x l 325mm) as per sample., all terms and condition and make of above items mentioned in bid document. the above rates are inclusive of all kind of taxes including gst.
Tender For ghrssidc/e-t/2026-27/646 - electrical fabrication - a, la cross arm clamp for 7.5 mt rcc pole (gal v) - cee/e/523, sa cross arm clamp for 7.5 mt rcc pole (gal v) - gec/e/523, la cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, sa cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, la cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, sa cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, la cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, sa cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, la cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, sa cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, la stay clamp for 60 lbs/yd rail pole (gal) - cee/e/469, sa stay clamp for 60 lbs/yd rail pole (gal) - cee e 469, la stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, sa stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, la stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, sa stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, la stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, sa stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, la stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, sa stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, 11 kv v shaped cross arm (gal v) - cee e 408, 33 kv v shaped cross arm (gal v) - cee e 408, b type modified distribution box - cee e 386, a type street light meter box with clamps - cee e 386, stay set for 11 kv lt line - cee e 500, stay set for 33 kv line - cee e 500, turn buckle& eye bolt for 33 kv line - cee e 513, turn buckle& eye bolt for 11 kv line -cee e 466, cast iron packing piece 90 lb for rail pole - cee e 514, top insulators fitting for rcc pole - cee e 506, 4 pin angle type cross arm - cee e 702, 4 pin channel type cross arm - cee e703, 2 pin angle type cross arm - cee e704, 2 pin channel type cross arm - cee e 705, earthing pipe - cee e 467, sa cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa bottom clamps for fixing street light fixtures for 7.5/9mtrs rcc pole galvanised 25 mm pipe - cee e 12, sa top bottom clamps for fixing street light fixtures for 7.5 mts rcc pole galvanised 25 mm pipe - cee e 12, la top clamps for fixing street light fixtures for 7.5/9 mts rcc pole (gal v) 40 mm pipe - cee e 612a, sa top clamps for fixing street light fixtures for 7.5 rcc pole - cee e 612a, gi nut and bolts in various sizes electro galvanised, gi pins for lt pin insulator, gi pins for 11kv pin insulator, gi pins for 33kv pin insulator, gi bent pipe of nominal base 25 mm, 1 mts long for tube light fixture - cee/e 618, gi bent pipe of nominal base 25 mm, 1.5 mts long for hpsv lamps - cee/e 593a, b type modified distribution box with mccb and kit kat fuses as per cees specifications / drawings, metal parts for shackle insulators as per cees specifications, gi bent pipe of nominal base bar 40mm x 3 mts long (medium class) the pipe shaft should conform to is : 1239 (part i) 1973 as amended upto date - ee/ii/21/2009, hot dip galvanised earthing strips of size 30x160x5mm, hot dip galvanised earthing strips of size 100 x 360 x 3mm, g.i bent pipe nominal bore 40 mm ce/e xi for hpsv lamps - cee/e 593a, metal parts for disc insulator as per department 4 bolted. as per department specification & drawing - 60/4/va/cee/tech/2019-20/1282, metal parts for disc insulator 3 bolted - 60/4/va/cee/tech/2019-20/1282, kit kat fuse 100 amps, kit kat fuse 200 amps, kit kat fuses 300 amps, kit kat fuse 400 amps, tinned copper fuse wire of various sizes, aluminium crimping lugs 25 sq.mm, aluminium crimping lugs 35 sq.mm, aluminium crimping lugs 50 sq.mm, aluminium crimping lugs 70 sq.mm, aluminium crimping lugs 95 sq.mm, aluminiu
Tender For supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply and installation and testing 11 kv outdoor type god , sitc of 200 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 50 kva to 200 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)