Get complete information related to latest Tubing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tubing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tubing Tenders.
Tender For corrigendum : repair and maintenance work of foot path and light arrangements,eb board,play materials and name board works in tnhb p-iii park at ward no.33 zone -4 in tcmc - eangaging of man power for cleaning weeds and bushes at lawn areas cutting plants and grass including all labour charges etc complete, gardener 5 days 6 nos, mazdoor ist class, engaging of ac electric grass cutter on hire basis including hire charges transport charges and all labour charges etc complete, supply and fixing of childerns play materials including cost and conveyance and fixing and proper alingenement charges etc complete, slider, 2 seater swing, 4 seater see saw, supplying and filling in foundation and basement with river sand in play area in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification., supply and fixing of light pole 4 metre length single bracket pole with base plate (250 x 250 x 6mm)76.10mm od x 3.65mm thick x 4000mm length etc.,completed, supply and fixing of 30w led street light fitting with led on out door fittings including cost and conveyance and fixing charges etc complete, supply and fixing of synthetic moulded compound box for street light with 16 a mcb and connecterincluding cost and conveyance and fixing charges etc complete box-735+16 a mcb sp and neutral -382, supply and fixing of 4 sqmm pvc unsheathed copper cable including cost and conveyance and fixing charges etc complete , supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good sd 194, centering and shuttering charges for all pcc and rcc works using ms steel moulds and soffits strutting with casurina props 10-13 cm dia including cost and conveyance of all materials and including all labour charges etc complete, plain cement concrete 1;2;4 mix using 20 mm hbg iss metal including cost and conveyance of all materials and including all labour charges etc complete, supply and filling of on quarry rubbish 15 cm thick on each layer including cost and conveyance and all labour charges for filling and consolidation charges etc complete, cement concrete 1:5:10 (one cement, five crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard speci cation and as directed by the departmental of cers. -mixing by manual means, paving the oor with pre-polished concrete anti-skid tiles (required shape and design) of 20mm thick of approved quality and colour laid in accordance with is 1443 over a cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required cement slurry and mortar plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard speci cation and as directed by the departmental of cers. (the make and brand of the tiles should be got approved by executive engineer before use on works), supply and fixing of m.s grills with doors and windows with one coat of red oxide with primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification., supply and fixing of stone bench including cost and conveyance and fixing and proper alingenement charges etc complete, supply and delivery of ms kiosk of size 0.75m x 0.45m x 0.75m made up of ms angle of size 50mm x 50mmx 4mm alround covered with 16 gauge ms sheet and kiosk door made up of ms plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,(twad sor 2025-26 unicode wd-m1471 clau
Tender For corrigendum : supply of nylon rope ladder complete with 1" dia. aluminum steps as per design. nylon rope of 25 mm dia. with steps of 25 mm dia. aluminum alloy corrugated tubing spaced at 12 c/c duly packed on both sides size 20 feet long with hook for hanging. specification as per attached annexure "a". [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For supply of flexible flame-retardant, high performance,polyolefin heat srinkable tubing, as per drawing: edml176, rev. '0', packing instruction: pi042 ver 3.0 (1) drawing no. icf/j&t/misc-2487 alt. `b? to be followed. (2) it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage, if any, shall be at the cost of supplier. for underframes: both (1) & (2) to be followed as stated above. for other items except underframes: only (2) need to followed. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of heavy duty pneumatic hose pipe , pvc core double braided with synthetic fiber, covered with thermo compound of black color, length 20 mtrs, dia-12.7mm, pressure17.85kg/cm2 and both ends fitted with threaded 0.5 inch female bsp fittings. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of opo 85 multiple- use (reusable, sterile) phaco tubing for compact intuitive phaco-emulsification system [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of abb make ph sensor , abb make ph analyzer , abb make conductivity analyzer , conductivity sensor , annual spares kit , tubing kit exc pump tubes , power supply board panel mount ac
Tender For corrigendum : supply of tubes and work of insitu retubing as per atc d d - aluminium brass seamless cold drawn tubes , end plate having size of o.d. 267mm, thickness 16.5mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 205mm, thickness 32mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 330mm, thickness 25mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 260mm, thickness 40mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , baffles having size of o.d. 205mm, thickness 04mm both end chamfer and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 25nos. , baffles having size of o.d. 260mm, thickness 04mm both end chamfer and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 19nos. , work of complete in situ re tubing of old damaged tube cooler of lube oil cooler of 210mw unit no. 3 and 4 as per atc , work of complete in situ re tubing of old damaged tube cooler of working oil cooler of 210mw unit no. 3 and 4 as per atc ) /bid number : gem/2026/b/7336822 * /dated: 14-04-2026 & & / bid document 1 / 12
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : repair to water proofing treatment for rcc roof and repair to chajja parapet water tank gi tubing and rain water pipe in domestic area at af stn nal under ge af nal