Web Analytics Made Easy - StatCounter

Turbine Pump Tenders

Get complete information related to latest Turbine Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45740717 Due date: 27 Jul, 202627 Jul, 2026 74.98 Lacs
Tender For providing, erecting, commissioning and giving satisfactory test and trial of 250 hp vertical turbine pumps and allied mechanical and electrical equipments for pumping raw water form jackwellat krishna ghat to water treatment plant at miraj

CTN :45740735 Due date: 27 Jul, 202627 Jul, 2026 2.32 Crore
Tender For providing, installing,commissioning vertial turbine pump 2 nos at karnal road jackwell, sangli

Central Government/Public Sector

CTN :45376467 Due date: 09 Jul, 202609 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire

State Government

CTN :45646140 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - supplying , installation, testing and commissioning of vertical turbine pump set with ss impeller capable to discharge 126 m3/hr.against total head of 50 m, (make kirloskar/jyoti/wilo-mather&platt/wpil) coupled with suitable capacity vertical hollow shaft/solid shaft squirrel cage induction motor , rating of motor 20% more bhp than that of pump (make kirloskar /abb /cgl/ siemens) operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply , ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,with heavy duty m.s. column assembly with ss line shaft and each coloumn of 5 feet length including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, strainer-1 no, m.s. channel base plate etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned vt pumpset make lk/bch/schneider., supplying and laying of 25 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., supplying, installation testing and commissioning of horizontal split casing centrifugal pump set with bronze impeller having discharge 126 m3/hr. against total head of 35 m, (make - kirloskar/jyoti/wilo-mather&platt/wpil), coupled with suitable capacity squirrel cage induction motor, rating of motor 20% more bhp than that of pump(make kirloskar /abb /cgl/ siemens) ,tefc, ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply, mounted on a commonm.s. base plate including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, foot valve-1no, etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned c/f pumpset make lk/bch/schneider., supplying and laying of 16 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., cost towards complete repairing of control panel at intake well with changing of damaged parts such as :-1.150 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 75 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load ., cost towards providing all labour, tools and technicians for taken out and dismantling 40 hp vt p/set with bowl assembly, 6" dia. coloumn pipe and line shaft etc all complete., cost towards dismantling and repairing of complete bowl assembly., cost towards making supplying and fitting s.s. top shaft as per size and sample., cost towards making supplying and fitting of c.i. spider bearing having od 6.5" with rubber bush as per size and sample., cost towards lowering of vt p/set. after complete repairing and assembling works., cost towards complete repairing of control panel at clear water pump house with changing of damaged parts such as :-1.125 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 63 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load .

CTN :45415159 Due date: 25 Jun, 202625 Jun, 2026 4.58 Lacs
Tender For corrigendum : repair and maintenance of tube wells and boosters including repair of water level gauge, ms panel, sluice valves and allied items of civil / electrical at various buildings i.e. punjab raj bhawan, haryana raj bhawan & residence sector-7, under maintennace booth, sector-7, chandigarh. (ch to: 2216 (np) mtc. and repair ) - repair of ci sluice valve up to 150 mm dia including dismantling, repair / replacement of spindle, nut , rubber packing, nuts and bolts complete., up to 100 mm dia, lifting and lowering of submersible pump set including dismantling of flenged joints, taking out column pipes, re-jointing etc including replacement of defective packing, nuts and bolts etc complete, tube well, booster, supplying and fixing of single phase preventor make minilec or equivalent model of approved make to the satisfaction of eic , supplying and fixing of current transformer ( ct ) for ampere meter of suitable rating complete., supplying and fixing of overload relay of following capacities, 14 to 23 amp, 30 to 42 amp, 45 to 75 amp, providing and fixing of star delta starter timer of make l&t or equivalent model of approved make to the satisfaction of eic, providing and fixing of kit kat 500 amp complete in all respect, supplying and fixing of capacitor of 20 to 50 mfd make l&t, siemens or equivalent model of approved make to the satisfaction of eic , supplying and fixing of analog meter of make l&t ( rishabh ) or equivalent model of approved make to the satisfaction of eic , volt meter, ampere meter, supplying and fixing of 3 pole mccb of following capacity of make l&t, bch, havells or equivalent model of approved make to the satisfaction of eic , 100 amp, supplying & fixing of contactors block of make l&t, bch or equivalent model of approved make to the satisfaction of eic , mnx - 25, mnx - 32, mnx - 50, mnx - 70, supplying and lowering of submersible cable 16mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , supplying and lowering of submersible cable 25mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , providing and fixing hydro pneumatic pump of size 0.5 hp of approved make with 24 ltr capacity tank, pressure switch, pressure gauge, nrv accessories and making connections complete of make crompton or equivalent model of approved make to the satisfaction of eic, repair and rewinding of submersible pump set including carriage from installation to workshop and back. the rate include replacement of all defective parts of pump and motor rewinding., 5 hp, 7.5 to 10 hp, 35 hp to 55 hp, repair and rewinding of monoblock submersible pumping set including repacement of defective parts as required and carriage from installation to workshop and back., 0.5 h.p, 1 h.p, 2 h.p, manufacturing, supplying and fixing of ms control panel 16 gauge of size 600x700mm with door including wiring of inside panel, complete in all respect, providing and fixing of self pumping monoblock single phase pump for boosting of make crompton or equivalent model of approved make to the satisfaction of eic, 0.5 h.p, 1 h.p, 2 h.p, providing and fixing of pressure gauge make h-guru or equivalent model of approved make to the satisfaction of eic, providing and fixing of elcb 63 amp make l&t/havells or equivalent model of approved make to the satisfaction of eic, repair of internal control wiring 1.5mm wire with thimbles, nut bolt etc. complete

CTN :45630058 Due date: 04 Jul, 202604 Jul, 2026 33.14 Lacs
Tender For supply and delivery of various stages (03 nos) submersible motor with suitable starter at kakavedu in ward no.02, (10 nos) 5hp submersible motor with suitable starter at a) rasappa colony in ward no.05, b) ngaari d/w in ward no. 06, c) netham st colony in ward no.09, d) prakash nagar ward no.15, (01 no) 40hp vertical turbine pump motor at ss tank and (20 nos) 7.5hp submersible motor with suitable starter, materials at a) ntr nagar in ward no.13, b) ekm kamaraja street in ward no. 14, c) karakantapuram d/w in ward no.17, d) sathrawada sc colony in ward no.20, e)sanjivee nagar in ward no.24, f) gandala street in ward no.26, chinthalapatteda d/w in ward no.27 g) raja street chinthalapatteda in ward no.28, h) chakala street in ward no.29 in nagari municipality

CTN :45608581 Due date: 06 Jul, 202606 Jul, 2026 10.00 Lacs
Tender For - supply for 60 hp 3 stage vt turbine pump bowl assembly capable to discharge 335 m3/hrat head 30 meter existing 250x39 mm dia complete, bowl bearing bronze, pump impeller shaft, line shaft and other material at nagr palika parisad mandla dist.mandla (m.p.)

CTN :45602957 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For maintenance of electrical installation and fans, street light including repair maintenance of water supply pumps and diesel generator set in sb-ocr complex at indira nagar, lucknow. (sh: supply, installation, testing and commissioning of pressure booster pumping system and replacement of post top led fitting)

State Government

CTN :45600848 Due date: 25 Jun, 202625 Jun, 2026 42.25 Lacs
Tender For repair and replacement of faulty 11/6.6kv c, and servicing of 2mva transformer & 100kva anxillary transformers along with 2 nos of 650hp ht vertical turbine pump and other accessories of tiluvalli lift irrigation scheme in hangal taluk haveri district

Central Government/Public Sector

CTN :45354608 Due date: 02 Jul, 202602 Jul, 2026 4.36 Crore
Tender For corrigendum : supply of horizontal centrifugal pump sets 38 lps x 160 mtrs head with flp 550 volts electricals & accessories , vertical turbine pump set, 350 lps x 65 mtr head with 6.6 kv electricals & accessories , vertical turbine pump set, discharge: 270 lps, head: 62 mtrs, electricals: 6.6 kv electricals & acc , horizontal centrifugal pump sets 180 lps x 170 mtr head with 3.3kv electricals & accessories , horizontal centrifugal pump sets, 100 lps and 180 mtrs head with 3.3kv electricals and accessories , horizontal centrifugal pump set 75 lps x 80 mtrs. head with 415 volts electrical & accessories , horizontal centrifugal bare pump 160 lps x180 mtrs head & accessories without prime movers & starter , horizontal centrifugal pump set, 180lps x 200mtr head, 6.6kv electricals and accessories
 Loading, Please wait...

Connect us via What's Up